Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: A2-12R-C
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 9% OFF

Panduit A2-12R-C 2 AWG 1/2" Stud Compression Lug

Panduit A2-12R-C 2 AWG 1/2" Stud Compression Lug The Panduit A2-12R-C Pan-Lug™ compression lug delivers reliable, code-compliant termination for 2 AWG…

$326.27 $295.99 SAVE $30

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit A2-12R-C 2 AWG 1/2" Stud Compression Lug

$326.27
$295.99

Overview

SKU: A2-12R-C
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit A2-12R-C 2 AWG 1/2" Stud Compression Lug

The Panduit A2-12R-C Pan-Lug™ compression lug delivers reliable, code-compliant termination for 2 AWG battery cable and power distribution applications. Designed for 1/2" stud connections, this tin-plated copper lug is engineered for the high-current, high-vibration environments found in UPS systems, emergency power installations, and critical infrastructure battery banks. Supplied in 100-piece packages, the A2-12R-C provides the consistency and performance commercial integrators need when terminating battery strings, generator tie-ins, or DC distribution panels.

Key Features

  • 2 AWG wire capacity with 1/2" stud size for heavy-duty battery and UPS connections
  • Tin-plated copper construction resists corrosion and ensures low-resistance contact over decades of service
  • Flared entry design guides wire insertion and reduces installation time in tight enclosures
  • Embossed wire size markings eliminate guesswork during termination and inspection
  • cULus Listed to UL 486A-486B for US and Canada power applications
  • Meets US Military Wire Pull Out Specifications for high-vibration and mission-critical installations
  • 100-piece package quantity supports multi-string battery installations and standardized inventories

The A2-12R-C uses high-conductivity copper barrel and tongue construction, tin-plated to resist oxidation in battery room environments where sulfation, humidity, and temperature cycling are constant threats. The flared entry on the barrel provides a generous lead-in that accommodates stranded 2 AWG conductors without pre-fanning, reducing prep time when terminating dozens of battery interconnects in a single installation. The embossed wire size on the barrel face ensures that inspectors and service techs can verify proper sizing without referencing prints or labels, a requirement on many AHJ inspections and UL 924 emergency power system validations.

Compression termination provides superior pullout strength compared to mechanical set-screw lugs, a critical factor in seismic zones or mobile power applications where vibration can loosen threaded connections over time. The A2-12R-C is designed for use with standard hex compression tools, creating a cold-weld bond between lug and conductor that meets US Military pull-out specs. This makes the A2-12R-C the preferred choice for battery strings feeding critical infrastructure—telecom CO battery plants, hospital UPS systems, data center 48VDC distribution, and solar + storage installations where a single failed termination can take down an entire branch.

cULus Listed to UL 486A-486B and compliant with US Military Wire Pull Out Specifications, the Panduit A2-12R-C compression lug is engineered for integrators who can't afford callbacks on power terminations. Whether you're landing battery leads on inverter terminals, building DC distribution busbars, or terminating generator neutral-ground bonds, the A2-12R-C delivers the mechanical and electrical performance the job demands.

Specifications
Brand: Panduit
MPN: A2-12R-C
Product Type: Compression Lug
Sub-Brand: Pan-Lug™
Wire Size: 2 AWG
Stud Size: 1/2 inch
Material: High-Conductivity Copper
Finish Coating: Tin-Plated
Overall Length: 2.16 inches
Package Quantity: 100
Carton Quantity: 0
Standards: cULus Listed (UL 486A-486B), US Military Wire Pull Out Specs
UPC: 61305671721
Features: Flared entry for ease of insertion, embossed wire size marking, high pullout strength for heavy duty applications
Competitor Parts: 192210236, 96129
Type: Battery
Connectivity: Parallel
Power: Battery
Power Type: Battery
Cable_Category: wire-termination
Carton_Qty: 0
Package_Qty: 100
Sub_Brand: Pan-Lug™
Wire Size: 2 AWG
Stud Size: 1/2"
Material: Copper
Finish: Tin-Plated
Product Type: Compression Lug
Overall Length: 2.16"
Package Quantity: 100
Standards: cULus Listed (UL 486A-486B), US Military Wire Pull Out Specs
Features: Flared entry, embossed wire size, high conductivity, high pullout strength
UPC: 061305671721
Sub-Brand: Pan-Lug™
Applications: Battery systems, UPS, power distribution
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources