Panduit A2/0-56RH-C 2/0 AWG Tin Compression Lug

Panduit A2/0-56RH-C Tin-Plated 2/0 AWG Compression Lug The Panduit A2/0-56RH-C is a tin-plated copper compression lug engineered for 2/0 AWG conductor…

$791.13 $715.99 SAVE $75

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit A2/0-56RH-C 2/0 AWG Tin Compression Lug

$791.13
$715.99

Overview

SKU: A2/0-56RH-C
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit A2/0-56RH-C Tin-Plated 2/0 AWG Compression Lug

The Panduit A2/0-56RH-C is a tin-plated copper compression lug engineered for 2/0 AWG conductors, delivering reliable terminations in battery systems, UPS installations, and power distribution applications where code compliance and long-term performance are non-negotiable. Part of Panduit's Pan-Lug™ family, this lug meets cULus requirements for use in both US and Canada under UL 486A-486B for power applications, and satisfies US Military wire pull-out specifications—critical for commercial installations where liability and uptime depend on termination integrity.

Key Features

  • 2/0 AWG wire capacity with tin-plated barrel for corrosion resistance and stable contact over decades
  • cULus Listed to UL 486A-486B for power applications in US and Canada
  • Meets US Military wire pull-out specifications for high-reliability terminations
  • 1.89" overall length fits standard battery posts and bus bars in confined enclosures
  • 100-piece professional pack reduces per-termination cost on multi-drop battery strings and UPS racks

Commercial battery and UPS installations demand terminations that survive decades of thermal cycling, vibration, and oxidation without creep or voltage drop. The A2/0-56RH-C addresses this through tin-plated copper construction—tin plating inhibits oxide formation at the contact surface while the heavy copper barrel maintains mechanical stability under compression. The compression crimp, when applied with the correct Panduit die, creates a cold-weld joint that exceeds the tensile strength of the conductor itself. This is why the lug satisfies both UL 486A-486B (the commercial building standard) and military pull-out specs: the joint won't fail before the wire does.

In practice, you'll deploy the A2/0-56RH-C on 2/0 conductors feeding battery terminals in telecom shelters, UPS battery strings in data centers, and solar combiner bus bars where NEC 690 or 706 applies. The 1.89" overall length fits standard battery terminal posts and distribution blocks without interference—critical in dense battery cabinets where every millimeter counts. The tin plating also solves the dissimilar-metal problem: when terminating to aluminum bus bars or plated steel studs, the tin layer prevents galvanic corrosion that would otherwise degrade contact resistance and generate heat.

This 100-piece pack is sized for commercial integrators running multi-battery strings or large UPS installations—eliminating mid-job supply runs and reducing per-lug cost on projects where twenty, forty, or eighty terminations are routine. Panduit's cULus listing and military-spec compliance mean the termination will pass AHJ inspection in any US or Canadian jurisdiction, and the published test data provides the documentation trail required for mission-critical facilities where every component requires traceability. For 2/0 AWG power terminations where code compliance, corrosion resistance, and decades-long reliability are baseline expectations, the A2/0-56RH-C delivers the engineering and third-party validation commercial projects demand.

Specifications
Brand: Panduit
MPN: A2/0-56RH-C
Product Type: Compression Lug
Sub-Brand: Pan-Lug™
Wire Size: 2/0 AWG
Stud Size: 5/16 inch
Finish Coating: Tin-Plated
Overall Length: 1.89 inches
Package Quantity: 100
Carton Quantity: 0
Standards Met: cULus Listed for use in US and Canada to UL 486A-486B for power applications, meets US Military Wire Pull Out Specs
Competitor Parts: 5956EV
UPC: 61305679322
Category: Wire Termination
Type: Battery
Power: 200A
Power Type: 200A
Cable_Category: wire-termination
Carton_Qty: 0
Package_Qty: 100
speed: 10G
Standards: cULus Listed for use in US and Canada to UL 486A-486B for power applications, meets US Military Wire Pull Out Specs
Sub_Brand: Pan-Lug™
Manufacturer: Panduit
Finish Coating: Tin-Plated Copper
Standards: cULus Listed UL 486A-486B, US Military Wire Pull-Out Specs
Package Quantity: 100 pieces
Application: Battery Terminals, UPS Systems, Power Distribution
Competitor Cross-Reference: 5956EV
Listing Agency: cULus (US and Canada)
Material: Copper with Tin Plating
Installation Method: Compression Crimp
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources