Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology C3B36RL-5CJE0AT2 0U 36-Outlet Ramlock HDO PDU
Overview
The Server Technology C3B36RL-5CJE0AT2 is a 0U vertical rack power distribution unit built for high-density data center cabinets that need three-phase 415V power split across 36 outlets without eating into usable rack space. This is a Basic (non-monitored) PDU in Server Technology's Ramlock HDO family, terminated with a NEMA L22-30P input plug rated for 30A input current (24A continuous rated) — enough to feed a fully loaded server or network rack without derating headaches. If you're standardizing a colocation footprint or refreshing a row of racks, the C3B36RL-5CJE0AT2 is a straightforward, monitoring-free option for cabinets where you're tracking load at the panel or upstream PDU level instead of per-strip.
Key Features
- 17.3kW Input Power Capacity: at 415V three-phase, this PDU supports dense GPU and blade server deployments where a single-phase strip would run out of headroom fast. Confirm your rack's actual draw against this ceiling before provisioning — it's the hard limit for the whole strip.
- 18x C13 Outlets Rated ≤12A @ 240V: covers standard server power supplies, switches, and most 1U/2U equipment without needing adapters. Twelve amps per outlet at 240V gives you real headroom for redundant PSU configurations.
- 18x Cx (C13/C19) Outlets Rated ≤16A @ 240V: the higher-rated outlet bank handles blade chassis and high-draw compute nodes that would trip a standard C13 circuit. Having both outlet classes on one strip means you don't need a second PDU for mixed-load racks.
- 36 Total Outlets on a 70-inch 0U Strip: at just 2.2in x 2.5in in cross-section, this mounts flush in the vertical rack channel and adds zero usable rack unit space — critical when every U in the cabinet is already spoken for.
- NEMA L22-30P Input Plug, 30A/24A Rated: a locking three-phase plug that won't walk out of the receptacle under vibration or cable strain — a real consideration in cabinets with heavy cable management pulling on the whip.
- Branch Circuit Breaker Protection ≤16A: each outlet branch is individually protected, so a fault or overload on one server doesn't take down the whole strip. Breakers are UL 489 and CSA C22.2 No. 5 compliant, and IEC/EN 60947-2 compliant for mixed-region deployments.
- 10 kAIC Interrupt Rating (North America): the breakers are rated to safely interrupt fault currents up to 10,000 amps, which matters in data centers where upstream fault current can be substantial — an underrated breaker is a fire risk, not just a nuisance trip.
- Unloaded Power Draw Under 10W: the PDU itself sips negligible power when idle, so it doesn't meaningfully add to your rack's cooling load or PUE calculations.
- Operating Range 0°C to 60°C / 8-90%RH: rated for standard data center environments plus hot-aisle containment scenarios that run warmer than typical 22°C setpoints — useful if you're running elevated-temperature ASHRAE profiles to cut cooling costs.
- 6,500ft/2km Operating Elevation: covers the overwhelming majority of North American data center sites, including higher-altitude facilities in mountain-region colocation markets.
- UL 62368-1 / CSA C22.2 No. 62368-1 Certified: audio/video and IT equipment safety certification for both US and Canadian deployments, relevant for facilities that require dual-market compliance documentation.
Integration & Compatibility
The C3B36RL-5CJE0AT2 (often searched as C3B36RL 5CJE0AT2) is a Basic PDU — it distributes power but does not include outlet-level or strip-level monitoring. If your operations team needs remote load visibility or per-outlet switching, look at monitored or switched variants in the same Ramlock HDO family rather than pairing this strip with add-on metering hardware. Because it terminates in a NEMA L22-30P plug, confirm your upstream panel or floor PDU has a matching L22-30R receptacle before ordering — three-phase locking connectors are not interchangeable across NEMA types. Pair this strip with properly rated three-phase upstream distribution and verify your rack's total connected load stays under the 17.3kW capacity, factoring in redundant PSU draw on server and network gear.
Frequently Asked Questions
Q: What input voltage and plug does the C3B36RL-5CJE0AT2 use?
A: It runs on 415V three-phase power at 50/60 Hz and terminates in a NEMA L22-30P locking plug rated for 30A input (24A continuous rated).
Q: How many outlets does the C3B36RL-5CJE0AT2 have and what are they rated for?
A: It has 36 total outlets: 18x C13 outlets rated up to 12A @ 240V and 18x Cx (C13/C19) outlets rated up to 16A @ 240V.
Q: Does the C3B36RL-5CJE0AT2 include outlet monitoring?
A: No. This is a Basic 0U PDU without outlet-level or strip-level monitoring. For load visibility, look at a monitored or switched model in the same Ramlock HDO family.
Q: What's the maximum power capacity of the C3B36RL-5CJE0AT2?
A: 17.3kW at 415V input, with individual branch circuits protected by breakers rated up to 16A each.
Q: What are the operating temperature and humidity limits?
A: Operating range is 0°C to 60°C and 8%RH to 90%RH, at elevations up to 6,500ft/2km.
Q: What certifications does the C3B36RL-5CJE0AT2 carry?
A: UL 62368-1 and CSA C22.2 No. 62368-1 safety certification, with branch circuit protection compliant to UL 489, CSA C22.2 No. 5, and IEC/EN 60947-2.

What stands out on the C3B36RL-5CJE0AT2 is the 17.3kW capacity on a 415V three-phase input — that's a lot of headroom packed into a 0U form factor, and it tells you this strip is meant for dense compute racks, not a lightly loaded network closet.
Technical Highlights:
- 36-Outlet Mixed Configuration: 18x C13 outlets at ≤12A/240V plus 18x Cx outlets at ≤16A/240V lets you mix standard server PSUs with higher-draw blade chassis on a single strip instead of running two separate PDUs.
- NEMA L22-30P Locking Input: rated for 30A input (24A continuous), this plug design keeps the connection secure in racks with heavy cable churn — no accidental disconnects from a snagged cable.
- 10 kAIC Interrupt Rating: the branch breakers are rated to safely clear fault currents up to 10,000A, which is the kind of fault current you actually see on upstream three-phase data center circuits, not a token spec.
Deployment Considerations:
- This is a Basic unit — no SNMP, no outlet metering, no remote switching. If your monitoring strategy depends on strip-level telemetry, this isn't the model; check the monitored or switched variants in the Ramlock HDO line instead.
- Confirm the upstream receptacle matches the NEMA L22-30P plug before the unit ships to site — three-phase locking connectors aren't interchangeable, and a mismatch means a return trip or a field-terminated adapter nobody wants to inspect later.
This is the right call for a colocation or enterprise data center row standardizing on 0U three-phase distribution with centralized monitoring elsewhere in the power chain — C3B36RL-5CJE0AT2 fits cabinets where rack space is at a premium and 36 outlets need to be split cleanly between standard and high-draw equipment.
Compare with similar
Server Technology Basic 0U 36 Ramlock HDO - C3B36RL-5CJE0AT2
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology