APC by Schneider Electric AR2580 - Schneider Electric - Netshelter SV 42U 800MM Wide X 1200MM Deep

APC by Schneider Electric AR2580 NetShelter SV 42U Rack EnclosureOverviewThe AR2580 is a 42U, 800mm-wide by 1200mm-deep rack enclosure from the APC by…

$3,115.00 $2,058.99 SAVE $1056
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC by Schneider Electric AR2580 - Schneider Electric - Netshelter SV 42U 800MM Wide X 1200MM Deep

$3,115.00
$2,058.99

Overview

SKU: AR2580
UPC: 731304302117
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric AR2580 NetShelter SV 42U Rack Enclosure

Overview

The AR2580 is a 42U, 800mm-wide by 1200mm-deep rack enclosure from the APC by Schneider Electric NetShelter SV series — a proven platform for housing dense server, network, and storage equipment in data centers, server rooms, and enterprise communications closets. At 19-inch rack width and 42U of usable height, it accommodates a full stack of 1U and 2U appliances without compromise. The 1200mm depth is the spec that matters most here: standard 1U servers, patch panels, cable managers, and high-density switching all fit with room for structured cabling behind the equipment — no forced cable bend-radius violations, no cramped rear access.

Finished in black, the AR2580 presents a clean, professional appearance suitable for data center floor deployments and executive equipment rooms alike. The enclosure ships as a single package unit weighing 352.9 lb, so plan your receiving dock and installation crew accordingly — this is not a one-person lift.

Key Features

  • 42U Capacity: Forty-two rack units of usable mounting space means you can fully populate a mixed environment — core switching, patch panels, 1U servers, and cable management — without immediately running out of vertical real estate. For a standard enterprise server room, a single AR2580 can anchor an entire network stack.
  • 800mm Wide Cabinet: The 800mm external width provides the extra horizontal clearance that 19-inch equipment demands when paired with side-entry cable management, blanking panels, and high-density fiber patch bays. Narrower 600mm racks force compromises; 800mm does not.
  • 1200mm Deep Enclosure: The 1200mm depth comfortably handles full-depth servers (most enterprise 1U/2U platforms run 650–800mm) plus rear cable management trays and airflow baffles without stacking conflicts. If you're running blade chassis or high-density GPU servers, this is the depth specification to confirm against your hardware vendor's clearance requirements.
  • 19-Inch Rack Rail Standard: EIA-310 19-inch rail mounting means every standard rack-mount device — switches, UPS units, KVM drawers, patch panels — installs without adapters or custom hardware. This is the universal mounting standard for enterprise IT equipment.
  • 307.5 lb (139.5 kg) Enclosure Weight: The empty cabinet weighs 307.5 lb, which tells you two things: the steel gauge is substantial (light cabinets flex under load), and your floor load calculations need to account for this before you add equipment. A fully populated 42U rack with servers and a tower UPS can easily reach 1,500–2,000 lb total — verify your floor loading spec early.
  • Black Finish: The standard black finish integrates cleanly into mixed-vendor data center environments and aligns with most raised-floor and hot-aisle/cold-aisle deployments. Consistent aesthetics matter in co-lo and enterprise settings where auditors and clients walk the floor.
  • Single Package Configuration: The AR2580 ships as one package unit at 352.9 lb. That shipping weight (vs. the 307.5 lb net) accounts for packaging materials and palletizing — factor both figures when planning freight, dock access, and installation labor.

Integration & Compatibility

The AR2580 accepts standard rack-mount accessories including APC's own NetShelter accessory line — side panels, roof fans, blanking panels, cable management arms, and power distribution units (PDUs) mount directly. The 19-inch rail standard ensures compatibility across virtually all enterprise IT vendors. For uninterruptible power supply integration, APC's own rack-mount UPS units (Smart-UPS, Symmetra) are designed to co-locate in this enclosure series. When planning a full rack build, confirm PDU rail compatibility and verify that your heaviest equipment (UPS, storage arrays) anchors to the bottom of the cabinet — both for stability and for maintaining low center of gravity during installation.

The 1200mm depth is the primary compatibility variable to verify against your deepest hardware. Standard enterprise servers typically require 650–800mm; cable management and airflow accessories add 50–100mm at the rear. The AR2580's depth provides margin for structured rear cabling without forcing equipment to overhang the front rail.

Frequently Asked Questions

Q: What is the usable rack unit capacity of the AR2580?

A: The AR2580 provides 42U of usable mounting space on standard 19-inch EIA-310 rails.

Q: What are the external dimensions of the AR2580?

A: The enclosure measures 80.98 inches (205.7 cm) in height, 800mm wide, and 1200mm deep.

Q: How much does the AR2580 weigh empty?

A: The empty enclosure weighs 307.5 lb (139.5 kg). The shipping package weighs 352.9 lb (160.1 kg), which includes packaging and palletizing materials.

Q: Is the AR2580 compatible with APC PDUs and UPS units?

A: Yes. The AR2580 is part of the NetShelter SV series and is designed to accept APC rack-mount PDUs and Smart-UPS/Symmetra rack-mount UPS units, as well as standard 19-inch accessories from other vendors.

Q: What equipment depth does the AR2580 support?

A: The 1200mm internal depth accommodates full-depth enterprise servers (typically 650–800mm) with rear clearance remaining for cable management and airflow accessories. Verify your deepest hardware's clearance requirements before ordering.

Q: What color is the AR2580?

A: The AR2580 is finished in black, standard for data center and server room deployments.

Marty Allison
Marty Allison

The AR2580 is the rack I reach for when depth is the deciding variable. At 1200mm deep and 42U tall, it handles full-depth enterprise hardware — blade chassis, dense storage arrays, top-of-rack switching — without forcing rear cable management into contorted configurations. The 307.5 lb empty weight signals serious steel construction; this cabinet does not flex under a full equipment load the way lighter alternatives do.

Technical Highlights:

  • 42U x 800mm Width: The wider 800mm footprint versus a 600mm cabinet gives you meaningful horizontal clearance for side-entry structured cabling, vertical cable managers, and blanking panels — equipment doesn't feel compressed even at full population.
  • 1200mm Depth: Most enterprise 1U/2U servers run 650–800mm chassis depth. The 1200mm internal depth leaves 200–400mm of rear space for cable management trays, airflow accessories, and PDU vertical mounting — the margin that keeps the back of the rack serviceable after year two.
  • 352.9 lb Shipping Weight: The delta between shipping weight (352.9 lb) and net weight (307.5 lb) is about 45 lb of packaging and pallet. Budget for a two-person install crew and a pallet jack — this is not a hand-truck job through a standard door.

Deployment Considerations:

  • At 80.98 inches (205.7 cm) tall, confirm your room's ceiling clearance and any raised-floor tile routing before positioning — overhead cable trays and HVAC drops can conflict with a cabinet this height during placement.
  • Floor loading is the gotcha most integrators catch late: the empty AR2580 at 307.5 lb plus a fully populated 42U (servers, UPS, switching) can easily push 1,500–2,000 lb total — always verify structural floor ratings before finalizing rack placement, especially on elevated floors or older facilities.

The AR2580 is the right call for enterprise server rooms and data center deployments running full-depth compute hardware where depth margin and build quality matter more than minimizing footprint — not the right fit for shallow-equipment telecommunications closets where a 600mm or 700mm-deep cabinet would reclaim floor space without penalty.

Specifications
Product Or Component Type: Rack enclosure
Number Of Rack Unit: 42U
Dimensions: 80.98 in (205.7 cm)
Weight: 307.5 lb (US) (139.5 kg)
Color: Black
Rack Width: 19"
Unit Type Of Package 1: PCE
Package 1 Weight: 352.881 lb (US) (160.064 kg)
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources