Vertiv APS 10KVA Scalable to 20KVA N+1 - AS4B0NCYGNNXLKB
10kVA uninterruptible power supply (UPS) designed for critical IT infrastructure
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv AS6B0NCWGNNXLKB is a 10kVA / 9.0kW hardwire uninterruptible power supply built for medium-density data rooms, network equipment rooms, and critical infrastructure deployments where scalability and redundancy are non-negotiable from day one. Starting at 10kVA with a clear upgrade path to 20kVA / 18.0kW, this unit is engineered to grow alongside your load — without requiring a full system replacement when capacity demands increase. Hardwire input (L-L-N-G) and hardwire output with optional PODs make this a fit for permanent, infrastructure-grade installations rather than plug-and-play desktop scenarios.
For teams planning phased deployments or protecting loads that will expand over a 3–5 year horizon, the AS6B0NCWGNNXLKB earns its place in the rack by eliminating the costly forklift upgrade that plagues fixed-capacity UPS platforms.
The AS6B0NCWGNNXLKB sits within Vertiv's APS scalable UPS family, which spans from 5kVA (AS5A0NCUGNNXLKB) through 20kVA (AS6D0NCJGNNXLKB). All models in the AS6-series share the same 20kVA / 18.0kW scalability ceiling, which means planning around a common platform is straightforward when standardizing across multiple rooms or facilities. The optional POD output architecture also allows integrators to adapt the output distribution to specific rack or row layouts without rewiring the UPS itself.
For UPS systems in this power class, hardwire installations typically pair with power distribution units downstream, and coordination with a Vertiv system architecture is straightforward given the consistent platform design across the APS line. Integrators specifying this unit alongside network infrastructure builds should factor in the POD accessory options early — retrofitting output distribution after installation adds unnecessary labor cost.
Q: What is the difference between the AS6B0NCWGNNXLKB and the AS6B0NCVGNNXLKB?
A: Both models are 10kVA / 9.0kW with a 20kVA scalability ceiling and hardwire I/O, but the battery configurations differ. The AS6B0NCVGNNXLKB provides 5 minutes at full load and 16 minutes at half load. The AS6B0NCWGNNXLKB provides 10 minutes at full load and 27 minutes at half load — the right choice when your generator transfer time or shutdown sequence requires more than 5 minutes of bridge time.
Q: What input wiring configuration does the AS6B0NCWGNNXLKB require?
A: The unit requires a hardwire L-L-N-G input — line, line, neutral, ground. This is a permanent installation requiring a licensed electrician. It is not compatible with standard NEMA plug configurations.
Q: Can the AS6B0NCWGNNXLKB be expanded beyond 10kVA without replacing the unit?
A: Yes. The unit is scalable to 20kVA / 18.0kW within the same platform, allowing capacity expansion as load requirements grow without a full system replacement.
Q: What runtime should I expect at half load on the AS6B0NCWGNNXLKB?
A: At 50% load (approximately 5kVA / 4.5kW), the unit delivers 27 minutes of runtime. At full 10kVA load, runtime is 10 minutes.
Q: Does the AS6B0NCWGNNXLKB support N+1 redundancy?
A: Yes. The system is designed for N+1 redundancy, allowing a second unit to be paired to provide failover protection if the primary unit experiences a fault.
Q: What output options are available on the AS6B0NCWGNNXLKB?
A: Output is hardwired. Optional Power Output Distribution (POD) modules are available to provide flexible downstream power distribution without altering the core UPS wiring.

The spec that sets the AS6B0NCWGNNXLKB apart from its closest sibling is straightforward: 10 minutes at full load versus 5 minutes on the AS6B0NCVGNNXLKB. That 5-minute delta sounds modest until you're in a generator transfer scenario and your transfer switch takes 7–8 seconds plus your generator spin-up adds another 30–45 seconds — and then your shutdown scripts need time to run graceful sequences across 20 servers. The 'W' battery variant in this family was clearly spec'd for exactly that gap.
Technical Highlights:
Deployment Considerations:
This unit is a strong fit for a phased edge data room buildout — a financial services branch office, a manufacturing plant control room, or a campus network hub where load will grow in 12–18 month increments and replacing the UPS at each phase is not an acceptable operational model.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Vertiv products? Shop the full Vertiv catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price