Vertiv APS 10KVA Scalable to 20KVA N+1 - AS6B0NCWGNNXLKB
10kVA uninterruptible power supply (UPS) module designed for critical infrastructure where continuous power is essential
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv AS4B0NCYGNNXLKB is a 10kVA / 9.0kW online UPS designed for facilities that need headroom to grow without ripping out infrastructure. Starting at 10kVA and scalable to 20kVA / 18.0kW within the same frame, this system suits data closets, edge deployments, and distributed critical power nodes where future load growth is a certainty, not a possibility. Hardwire input (L-L-G) and hardwire output — with optional POD expansion — make it a fit for permanent, rack-integrated or floor-mounted commercial power installations rather than plug-in desktop applications.
Runtime at full 10kVA / 9.0kW load is 21 minutes, which is enough for a controlled shutdown or generator transfer in most facility scenarios. Drop to half load (4.5kW) and that extends to 51 minutes — practical coverage for brief utility outages without generator support. If your load profile is mixed or partially redundant, the half-load figure is often the more operationally relevant number to plan against.
The AS4B0NCYGNNXLKB sits within a broader Vertiv APS family spanning 5kVA through 20kVA, all sharing the same hardwire input/output topology and optional POD ecosystem. This consistency matters when standardizing across multiple sites or expanding an existing deployment — the operational model, wiring approach, and accessory ecosystem carry over. Models in the same family with lower runtime (the AS4B0NCVGNNXLKB at 5-minute full-load) are available when battery cost is the primary constraint and generator coverage is confirmed. Models with higher base capacity (AS4C and AS4D series) cover 15kVA and 20kVA starting points for larger rooms or higher-density deployments.
For installations with mixed critical and non-critical loads, pairing this UPS with a downstream power distribution unit allows selective protection — keeping the UPS load budget focused on what actually requires battery backup. Integrators building out structured rack environments should review the broader Vertiv power and cooling catalog for compatible PDUs, monitoring cards, and environmental sensors that integrate with this platform. Those planning multi-rack or data center edge buildouts will benefit from reviewing a UPS selection guide to match runtime curves against generator transfer SLAs before committing to a battery configuration. Critical power infrastructure planning at the facility level — particularly where N+1 is a design requirement — should account for the full scalability path this unit supports.
Q: What is the full-load runtime of the AS4B0NCYGNNXLKB at 10kVA?
A: At full load (10kVA / 9.0kW), the AS4B0NCYGNNXLKB delivers 21 minutes of runtime. At half load (approximately 4.5kW), runtime extends to 51 minutes.
Q: Can the AS4B0NCYGNNXLKB scale beyond 10kVA without replacing the unit?
A: Yes. The AS4B0NCYGNNXLKB is scalable to 20kVA / 18.0kW within the same product family, supporting N+1 redundancy configurations as load requirements grow.
Q: What type of input connection does the AS4B0NCYGNNXLKB require?
A: The AS4B0NCYGNNXLKB uses hardwire (L-L-G) input. This is a permanently wired installation requiring a licensed electrician — it is not a plug-in appliance.
Q: What output options are available on the AS4B0NCYGNNXLKB?
A: Output is hardwire, with optional POD (Power Output Distribution) modules available for installations that require downstream receptacle-based distribution in addition to hardwired loads.
Q: How does the AS4B0NCYGNNXLKB differ from the AS4B0NCVGNNXLKB?
A: Both models share the same 10kVA / 9.0kW capacity and 20kVA scalability ceiling. The key difference is battery configuration: the AS4B0NCYGNNXLKB provides 21-minute full-load / 51-minute half-load runtime, while the AS4B0NCVGNNXLKB provides only 5-minute full-load / 15-minute half-load runtime — appropriate when generator transfer times are very short and battery cost is a constraint.
Q: Is the AS4B0NCYGNNXLKB appropriate for a single-phase or three-phase installation?
A: The hardwire L-L-G input configuration indicates a single-phase hardwire installation (line-line-ground). Confirm wiring compatibility with your facility electrician before procurement.

The spec that drives most purchasing decisions on the AS4B0NCYGNNXLKB is the 21-minute full-load runtime at 10kVA / 9.0kW — that is the number that tells you whether this unit buys enough time for your generator to transfer and stabilize before protected loads go dark. In most commercial and light-industrial facilities with diesel backup, that window is more than sufficient. What distinguishes this SKU from its sibling AS4B0NCVGNNXLKB is exactly that battery configuration: four extra minutes versus sixteen minutes of additional ride-through at full load is not a minor difference when your SLA depends on it.
Technical Highlights:
Deployment Considerations:
The AS4B0NCYGNNXLKB is the right specification for a permanent edge data room or distributed IDF closet where loads are expected to grow over a 3–5 year window, generator transfer is confirmed but not instantaneous, and the installation is being built to last — not to be replaced at the next capacity review.