APC Smart-ups Modular Ultra 15KW Scalable to 15KW N+1 Redundant Tower 208/240V - SRYL15K15XLT24

APC by Schneider Electric SRYL15K15XLT24 15KW N+1 Redundant Modular Tower UPSOverviewThe APC Smart-UPS Modular Ultra SRYL15K15XLT24 is a 15KW tower UP…

$59,215.00 $40,026.99 SAVE $19188
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC Smart-ups Modular Ultra 15KW Scalable to 15KW N+1 Redundant Tower 208/240V - SRYL15K15XLT24

$59,215.00
$40,026.99

Overview

SKU: SRYL15K15XLT24
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric SRYL15K15XLT24 15KW N+1 Redundant Modular Tower UPS

Overview

The APC Smart-UPS Modular Ultra SRYL15K15XLT24 is a 15KW tower UPS built for three-phase-adjacent data center edge deployments and large server rooms where a single point of failure is unacceptable. The modular architecture scales to 15KW and supports N+1 redundancy — meaning you can lose one power module and continue operating without interruption, which is the baseline expectation in any always-on compute or network environment. It runs on 208 V AC input and delivers 120 V AC output with a true sine wave waveform, making it compatible with the full range of enterprise-grade servers, storage arrays, and networking equipment that demand clean, regulated power.

The Li-Ion battery chemistry is a meaningful departure from traditional VRLA designs. Lithium-Ion batteries handle more charge/discharge cycles before capacity degradation, operate effectively across a wider temperature range, and typically offer a longer service life — all of which reduce total cost of ownership in facilities where battery replacement is a recurring maintenance line item. For a power protection system at this scale, that lifecycle difference compounds quickly across a multi-year deployment.

Key Features

  • 15KW Modular Capacity with N+1 Redundancy: The modular design lets you deploy redundant power modules in a single tower footprint. N+1 means one module can fail or be hot-swapped without dropping load — eliminating the single-point-of-failure risk that disqualifies basic UPS units from critical infrastructure roles. Review the full APC by Schneider Electric catalog for the broader Smart-UPS Modular Ultra family.
  • True Sine Wave Output: Unlike stepped-approximation waveforms from some online-interactive units, the sine wave output is required for active PFC power supplies common in rack servers, VMware hosts, and high-density storage. Deploy this where generic UPS units have caused server PSU trips or warranty voids.
  • 208/240V Input Flexibility: Accepts 208 V AC input — standard in North American three-phase commercial electrical environments — making it a natural fit for raised-floor data centers, network operations centers, and dense IDF/MDF rooms already wired at that voltage. Consult your UPS and power infrastructure planning guide before specifying input wiring runs.
  • Li-Ion Battery Technology: Lithium-Ion chemistry delivers a longer cycle life and faster recharge versus VRLA alternatives. In a facility where runtime tests and annual battery maintenance are scheduled events, the reduced replacement frequency directly lowers operational overhead. Pair with an appropriate server room power accessory kit for a complete installation.
  • Tower Form Factor at Scale: At 47.2 in (1,198 mm) tall and 470.5 lb, this is a floor-standing unit. Plan floor load ratings and access clearances before installation — this is not a retrofit for constrained spaces, but it consolidates significant power protection capacity into a single deployable unit.
  • 120 V AC Output: Downstream equipment connects at 120V, covering the standard North American server and networking load profile without step-down transformers at the rack level.

Integration & Compatibility

The SRYL15K15XLT24 is positioned for environments running enterprise network management platforms. APC's EcoStruxure IT and Network Management Cards (sold separately) enable SNMP-based monitoring, automated shutdown scripting, and integration with VMware, Microsoft SCVMM, and similar hypervisor management layers. Verify NMC slot compatibility and network management card SKU against your management platform before purchasing. For large-scale deployments, coordinate with a data center power planning resource to confirm load calculations and input circuit sizing at 208V.

Frequently Asked Questions

Q: What is the input voltage requirement for the SRYL15K15XLT24?

A: The SRYL15K15XLT24 requires 208 V AC input, which is standard in North American commercial three-phase electrical environments.

Q: What type of battery does the SRYL15K15XLT24 use?

A: It uses Li-Ion (Lithium-Ion) battery technology, which offers longer cycle life and lower maintenance frequency compared to traditional VRLA batteries at this power class.

Q: Does the SRYL15K15XLT24 output a true sine wave?

A: Yes. The output waveform is a true sine wave, which is required for active PFC power supplies found in most modern enterprise servers and storage equipment.

Q: What does N+1 redundancy mean for this UPS?

A: N+1 redundancy means one additional power module beyond the minimum required load capacity is installed. If one module fails, the remaining modules continue to carry the full load without interruption or manual intervention.

Q: How much does the SRYL15K15XLT24 weigh, and what are its dimensions?

A: The unit weighs 470.5 lb (213.4 kg) and stands 47.2 in (1,198 mm) tall. Floor load capacity and installation clearances must be verified before deployment.

Q: Can the SRYL15K15XLT24 scale beyond 15KW?

A: Per the product designation, this unit is scalable to 15KW within its modular architecture. For capacity requirements beyond 15KW, parallel or additional UPS units would be required.

Jerry Tildsen
Jerry Tildsen

At 470.5 lb and 47.2 inches tall, the SRYL15K15XLT24 is not a casual purchase — it's a committed infrastructure decision. When I evaluate a unit at this scale, the two questions that matter are load architecture and battery maintenance cost over the deployment lifetime. The Li-Ion chemistry here answers the second question directly: you're looking at significantly fewer battery replacement cycles compared to VRLA at equivalent power ratings, which at 15KW makes a real difference in total facility operating cost over a 5–10 year horizon.

Technical Highlights:

  • N+1 Modular Redundancy: The modular design allows one power module to fail or be pulled for service while the unit continues delivering full 15KW load — this is the architecture requirement for any Tier III equivalent power zone, not a nice-to-have.
  • True Sine Wave at 120V Output: Every modern server PSU with active PFC requires a sine wave input. A stepped approximation from a line-interactive unit can cause PSU trips under load transitions — the SRYL15K15XLT24 eliminates that failure mode entirely.
  • Li-Ion Battery Chemistry: Longer cycle life, better thermal performance, and faster recharge versus VRLA. In a facility running regular runtime tests and scheduled maintenance, the reduced battery swap frequency is a measurable operational cost reduction over a multi-year deployment.

Deployment Considerations:

  • At 470.5 lb, floor load ratings must be confirmed before siting. Raised-floor environments need structural assessment at the tile or pedestal level — do not assume standard raised-floor panels handle this without engineering sign-off.
  • The 208V input requires a dedicated 208V circuit — verify panel capacity and breaker sizing before the unit arrives on site. A last-minute circuit upgrade is an avoidable delay on a data center commissioning schedule.

The SRYL15K15XLT24 is the right specification for a network operations center or edge data hall where N+1 power redundancy is a contractual or SLA requirement and where the facility team wants to reduce battery maintenance events over the life of the deployment.

Specifications
Main Input Voltage: 208 V AC
Main Output Voltage: 120 V AC
Battery Type: Li-Ion (Lithium Ion)
Color: Black and silver
Dimensions: 47.2 in (1198 mm)
Weight: 470.5 lb (US) (213.4 kg)
Wave Type: Sine wave
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources