Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The APDU9981NA3 is a vertically mounted, zero-U switched rack PDU delivering 11.5kW of three-phase power across 24 mixed-type outlets in high-density data center and server room deployments. Where a basic metered PDU only tells you what's happening, this switched unit lets you remotely cycle individual outlets — critical for rebooting locked servers, cycling PoE switches, or gracefully shedding non-essential loads without dispatching anyone to the rack. If your operations team manages infrastructure across multiple sites or works outside normal business hours, per-outlet switching is the spec that justifies the price delta over a metered or monitored unit.
Designed for rack cabinets running three-phase 415V input at 50–60 Hz, the APDU9981NA3 handles environments where single-phase power distribution simply can't support the load density — think blade server chassis, GPU compute racks, or high-density storage arrays running alongside UPS and power distribution infrastructure. The 0U vertical form factor keeps the PDU mounted in the rear vertical channel of the rack, preserving every usable U of rack space for active equipment.
The APDU9981NA3 integrates with APC rack PDU management infrastructure including APC's Network Management Card ecosystem, enabling SNMP, Modbus, and RESTful API access for power monitoring and outlet control via datacenter infrastructure management (DCIM) platforms. Per-outlet switching enables integration with automated runbook systems, server management platforms (e.g., iDRAC, iLO, IPMI-triggered scripts), and NOC ticketing workflows where outlet reboot is a remediation action.
The mixed C13/C15/C19/C21 outlet configuration is compatible with standard IEC-compliant server, storage, and networking equipment from all major vendors. The 415V three-phase input is designed for international electrical infrastructure — coordinate with your facilities team to confirm your rack PDU panel or busway tap delivers 415V three-phase before provisioning this unit. For North American 208V three-phase environments, verify compatibility with the specific input voltage spec before deployment. Pair with compatible server racks and enclosures that support vertical rear-channel PDU mounting.
For projects requiring per-outlet power monitoring in addition to switching — useful when you need kilowatt-hour billing per tenant in co-location or per-rack chargeback in enterprise IT — confirm whether this model includes per-outlet metering or whether a higher-tier PDU model in the APC by Schneider Electric power distribution line is required. If your deployment also needs environmental monitoring (temperature, humidity, contact closure), APC's sensor port ecosystem connects to the management card separately.
Q: What input voltage does the APDU9981NA3 require?
A: The APDU9981NA3 requires a three-phase 415V input at 50–60 Hz. This is an international/industrial voltage standard common in European data centers and co-location facilities. Confirm your facility's PDU panel or busway tap delivers 415V three-phase before ordering — this unit is not designed for standard North American 208V single-phase circuits.
Q: What types of outlets does the APDU9981NA3 provide?
A: The APDU9981NA3 provides 24 AC outlets across four IEC coupler types: C13 (standard servers/networking), C15 (higher-temperature applications), C19 (high-current devices), and C21 (high-current, higher-temperature). The specific outlet count per type should be confirmed against the product documentation, but the mix supports a wide range of rack equipment without adapter proliferation.
Q: Does the APDU9981NA3 support remote outlet switching?
A: Yes. As a switched PDU, the APDU9981NA3 supports per-outlet remote on/off and reboot — the core capability that distinguishes it from metered or monitored PDU tiers. This enables remote power cycling of locked devices without physical rack access, and integrates with APC's Network Management Card for SNMP/API-based control.
Q: What is the maximum power load for the APDU9981NA3?
A: The APDU9981NA3 supports a maximum load of 11,500W (11.5kW) / 11,000 VA, with a maximum current of 16A. This capacity is suited for high-density compute racks, blade server chassis, and mixed server/storage environments where single-phase PDUs would be insufficient.
Q: What certifications does the APDU9981NA3 carry?
A: The APDU9981NA3 is certified to UL 62368-1, CUL, FCC 15A, and PSE standards, and carries RoHS compliance for sustainability requirements. UL 62368-1 is the current North American IT/AV safety standard; PSE covers Japanese market deployment; RoHS compliance supports EU and green-procurement frameworks.
Q: Does the APDU9981NA3 take up rack unit space?
A: No. The APDU9981NA3 is a 0U device that mounts vertically in the rear channel of a standard rack enclosure. It consumes zero rack units, preserving full U capacity for active compute, storage, and networking equipment.

The APDU9981NA3 is the unit I specify when a rack is already at capacity and the team needs per-outlet remote control on three-phase infrastructure. The 0U vertical form factor is non-negotiable in fully loaded 42U cabinets, and the 11.5kW / 16A capacity on 415V three-phase gives you enough headroom for dense mixed workloads without running the PDU near its thermal ceiling during peak draw.
Technical Highlights:
Deployment Considerations:
The APDU9981NA3 is the right call for international co-location deployments, European data centers, and industrial compute racks running 415V three-phase infrastructure where per-outlet switching and 0U vertical mounting are both required — not for standard North American office server rooms.