APC Netshelter Soundproof 32U Server Rack Enclosure 120V Maple - AR4032A

APC by Schneider Electric AR4032A Soundproof 32U Server Rack EnclosureOverviewThe APC by Schneider Electric AR4032A is a 32U soundproof server rack en…

$9,255.00 $5,955.99 SAVE $3299
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC Netshelter Soundproof 32U Server Rack Enclosure 120V Maple - AR4032A

$9,255.00
$5,955.99

Overview

SKU: AR4032A
UPC: 731304621768
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric AR4032A Soundproof 32U Server Rack Enclosure

Overview

The APC by Schneider Electric AR4032A is a 32U soundproof server rack enclosure designed for deployments where noise reduction is a hard requirement — open office areas, retail back rooms, branch IT closets, or any environment where a standard open-frame or vented rack would create unacceptable acoustic disruption. The AR4032A pairs a 19-inch standard rail configuration with an 11.98 ft (3.65 m) power cable and a 10-outlet NEMA 5-15R PDU, delivering a self-contained infrastructure unit ready to receive standard 1U through chassis-mounted equipment. The maple finish sets it apart from the black enclosures that dominate the market — a deliberate choice for environments where the enclosure is visible to staff or clients.

Key Features

  • 32U Capacity, 19-inch Rail Width: Accommodates standard EIA-310 equipment across the full 32U height. Enough room for a mid-size switching stack, patch panels, a few 1U servers, and PDU management — without requiring a full 42U footprint or a dedicated server room.
  • Soundproof Enclosure Design: The acoustic treatment is the defining reason to specify the AR4032A over a standard vented rack. If your integration puts network gear in a classroom, retail floor, or open workspace, the sound-dampening structure keeps fan noise from becoming a facility complaint.
  • 1,500 kg (3,306.9 lb) Static Load Rating: The floor-mounted frame handles dense equipment loadouts without structural compromise. That figure covers even fully populated UPS-plus-switching configurations — you're not going to stress this enclosure with typical IT or security head-end gear.
  • Integrated 10-Outlet NEMA 5-15R PDU with NEMA 5-15P Input: The onboard PDU runs on 100–120V at 50/60 Hz input. Ten NEMA 5-15R outlets handle standard North American equipment without adapters — practical for mixed security and IT loads like NVRs, switches, and access control servers sharing a single enclosure.
  • 11.98 ft (3.65 m) Power Cable: Long enough to reach a wall outlet or floor-mounted PDU without an extension cord. In retrofit installs where the nearest circuit may be across a raised floor tile, this reach matters.
  • Maple Color Finish: Specified for environments where appearance is part of the brief — executive offices, reception areas, or anywhere a black server rack would read as out of place. Functionally identical to the standard enclosure, purely a visual differentiator.
  • 476.2 lb (216 kg) Enclosure Weight: Factor this into your delivery and positioning plan. Two-person lift or pallet jack required for any stair or threshold crossing. Confirm floor load ratings before positioning on upper floors or mezzanines.

Integration and Compatibility

The AR4032A accepts any standard 19-inch rackmount equipment. The integrated PDU covers typical security infrastructure loads — NVRs, managed PoE switches, access control servers, intercom gateways — as long as individual devices draw within standard NEMA 5-15 amperage limits. The 32U height fits a complete small-to-midsize physical security head-end without needing a larger enclosure. For network switches and network video recorders, verify total PDU amperage draw before populating all 10 outlets. Pair with an APC UPS on a dedicated circuit if uptime requirements demand battery backup — the enclosure weight budget supports a tower or rack UPS mounted at the base. Review the rack and enclosure category for mounting accessories, cable managers, and blanking panels compatible with this form factor. If acoustic isolation is not required, see a standard server rack enclosure in the same U-count range for lower cost and weight.

Frequently Asked Questions

Q: What is the rack unit capacity of the AR4032A?

A: The AR4032A provides 32U of usable rack space on a standard 19-inch rail configuration.

Q: How many power outlets does the built-in PDU provide?

A: The integrated PDU includes 10 NEMA 5-15R outlets with a NEMA 5-15P input plug and an 11.98 ft power cable.

Q: What is the maximum static load capacity?

A: The AR4032A is rated for 1,500 kg (3,306.9 lb) static load — sufficient for fully populated equipment configurations including UPS units.

Q: Why does the AR4032A weigh so much compared to a standard rack?

A: The 476.2 lb (216 kg) weight reflects the acoustic dampening materials built into the enclosure walls and doors. This mass is what reduces fan and drive noise — it is not excess material.

Q: Is the AR4032A suitable for open office or client-facing areas?

A: Yes. The soundproof construction and maple finish are specifically suited for deployments where the enclosure is visible or where noise levels are a concern — retail back offices, reception areas, or open workspace IT closets.

Q: What input voltage does the AR4032A require?

A: The integrated PDU accepts 100–120V at 50/60 Hz via a standard NEMA 5-15P plug — compatible with standard North American circuits.

Eden Phillips
Eden Phillips

The AR4032A addresses a gap that standard rack specs don't cover: what do you do when the head-end has to live outside the server room? The 476.2 lb enclosure weight is the acoustic story — that mass is damping material, not structural over-engineering, and it's what makes this unit viable in open-plan offices or retail environments where a vented rack's fan noise would be a daily complaint.

Technical Highlights:

  • 1,500 kg Static Load Rating: At 3,306.9 lb rated capacity, you can fully populate all 32U with dense switching, UPS, and NVR hardware without approaching the structural limit — this enclosure won't flex or rack-shift under real IT/security loads.
  • 10-Outlet Integrated PDU: The NEMA 5-15R strip covers a complete small security head-end — NVR, managed PoE switch, access controller, and intercom gateway — from a single NEMA 5-15P input. The 11.98 ft cord reaches most in-room circuits without an extension.
  • Maple Finish: Not cosmetic fluff — it's the spec that gets this enclosure approved by facilities and interior design teams in client-visible spaces. If the color doesn't match the brief, the standard black variant serves the same acoustic function.

Deployment Considerations:

  • At 476.2 lb empty, delivery and positioning require two people minimum and a pallet jack for any threshold crossing. Confirm floor load ratings before placing on upper floors or mezzanines — this is not a standard rack weight class.
  • The NEMA 5-15 PDU is rated for 120V North American circuits only. International deployments or 208V rack PDU requirements need a different enclosure or an external PDU — the built-in strip is not field-configurable for higher voltages.

The AR4032A is the right call for a physical security head-end or branch IT closet in a space where acoustic performance and appearance are written into the site requirements — not a general-purpose rack substitution.

Specifications
Product Or Component Type: Rack enclosure
Main Input Voltage: 100...120 V
Input Connection Type: NEMA 5-15P
Output Connection Type: 10 NEMA 5-15R
Number Of Rack Unit: 32U
Cable Length: 11.98 ft (3.65 m)
Dimensions: 65.9 in (1675 mm)
Weight: 476.2 lb(US) (216 kg)
Color: Maple
Rack Width: 19"
Permanent Permissible Load: 3306.9 lb(US) (1500 kg) static
Input Frequency: 50/60 Hz
Pdu Type: UNSPSC Code
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources