Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: AP4450A
UPC: 731304432517
Condition: New
Write a Review 33% OFF

APC Netshelter Rack Automatic Transfer Switch 1U 15A 100/120V 5-15 in 10 5- - AP4450A

APC by Schneider Electric AP4450A NetShelter Rack Automatic Transfer SwitchOverviewThe APC by Schneider Electric AP4450A is a 1U rackmount Automatic T…

$2,115.00 $1,406.99 SAVE $708
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC Netshelter Rack Automatic Transfer Switch 1U 15A 100/120V 5-15 in 10 5- - AP4450A

$2,115.00
$1,406.99

Overview

SKU: AP4450A
UPC: 731304432517
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric AP4450A NetShelter Rack Automatic Transfer Switch

Overview

The APC by Schneider Electric AP4450A is a 1U rackmount Automatic Transfer Switch (ATS) designed to provide continuous power to connected equipment by switching between two independent power sources — automatically and without interruption — when one source fails or drops out of acceptable voltage range. With 10 NEMA 5-15R outlets and a 15A input rating at 100/120V, this unit targets server racks, network closets, and edge-compute environments where a single-corded PDU is the weakest point in power availability. If you're running dual-corded servers and have a second power feed available, the AP4450A makes those two feeds work together as a live-active redundancy pair rather than a passive backup arrangement.

The AP4450A occupies a single rack unit (1U) in a standard 19-inch rack, measuring 432 mm wide × 236 mm deep × 44 mm tall. The front-panel LCD gives at-a-glance status on both input sources — voltage, current draw, and active feed — without requiring network access or a management session. That local visibility matters during an incident when you need to confirm which feed is carrying load before you start tracing cables.

Key Features

  • Automatic Source Switching: When the active input drops below or exceeds the operating window (90–110V), the AP4450A transfers load to the alternate source without manual intervention. For equipment running 24/7 — NAS arrays, core switches, hypervisors — that automatic failover is the difference between a logged event and an unplanned outage.
  • 15A / 100–120V Input Rating: A single 15A draw across 10 outlets gives you up to 1,440W of usable capacity at 120V (derate to 80% per NEC = 1,152W continuous). Size your connected load accordingly — this is not a high-density power platform, but it covers a full shelf of 1U edge appliances or a mix of network gear and storage.
  • 10 x NEMA 5-15R Outlets: All ten receptacles are standard North American 5-15R — compatible with the vast majority of 1U rack equipment, IP cameras, NVRs, and networking devices shipped with a standard NEMA 5-15P plug. No adapter or whip required for typical deployments.
  • 50–60 Hz Input Frequency Acceptance: The ATS accepts both 50 Hz and 60 Hz power feeds, which matters if you're deploying in mixed-frequency environments or importing the unit into a 50 Hz facility. Both feeds must be within spec for the transfer logic to function correctly.
  • LCD Front Panel Display: Real-time readout of both input source parameters and active load status without requiring SNMP, a management card, or a network session. Useful during commissioning and fault diagnosis — you can confirm both feeds are live and balanced before you connect load.
  • Wide Operating Temperature Range (-5°C to 45°C): Covers most controlled data center and IDF environments. The upper limit of 45°C accommodates warmer-aisle conditions or lightly cooled edge racks without thermal derating. Storage range extends to -25°C / 65°C for shipping and warehousing in cold or hot climates.
  • Operating Humidity 5–95%: Non-condensing tolerance across the full range means the unit handles the humidity swings common in industrial edge environments, shipping containers, and manufacturing-floor wiring closets — places where a tighter humidity spec would require additional climate control.
  • 1U Rackmount Form Factor (432 × 236 × 44 mm): Standard 19-inch rack width with a shallow 236 mm depth — fits in short-depth wall-mount enclosures and two-post relay racks that can't accommodate a full-depth unit. The 44 mm height is exactly 1U, leaving no wasted rack space.
  • Black Anodized Finish: Consistent with standard rack equipment aesthetics — no custom bracket or color-match work needed in a professional rack installation.

Integration & Compatibility

The AP4450A draws from two independent NEMA 5-15P input sources — typically two separate branch circuits or a utility feed and a UPS output. Both source circuits should be on separate breakers and, ideally, separate panels or UPS units to achieve genuine redundancy. Connecting both inputs to the same breaker panel defeats the purpose: a panel-level fault takes both feeds simultaneously.

This unit is part of the broader APC by Schneider Electric rack power lineup, which includes matched PDUs, UPS units, and rack enclosures. It integrates well into existing APC NetShelter rack infrastructure. For full rack power distribution planning — including how to size UPS capacity against ATS input ratings — review the APC rackmount power guide. Pairing this ATS with a compatible UPS on each input source is the standard architecture for Tier II+ power availability in network rack enclosures.

If your load requires higher current (20A or 30A circuits) or 208V/240V input for denser server platforms, evaluate higher-rated ATS models within the APC NetShelter ATS family before spec-ing this unit. The AP4450A is scoped specifically for 15A/120V North American distribution.

Frequently Asked Questions

Q: What is the maximum continuous load the AP4450A can support?

A: The AP4450A is rated for 15A input at 100–120V. Following the NEC 80% continuous load rule, maximum continuous load is 12A — approximately 1,440W at 120V derated to 1,152W for 24/7 operation. Do not run the unit at the full 15A rating continuously.

Q: Does the AP4450A require both inputs to be on the same voltage and frequency?

A: Both inputs must be within the operating voltage window of 90–110V and within the 50–60 Hz frequency range. The two feeds should be electrically compatible — mismatched frequencies or voltage tiers outside this range will affect transfer logic and may result in load drops rather than clean transfers.

Q: What type of outlets does the AP4450A provide?

A: The AP4450A provides 10 NEMA 5-15R receptacles — standard North American 15A/125V outlets compatible with equipment shipped with a NEMA 5-15P plug. No adapters are required for typical rack-mounted devices.

Q: Can the AP4450A be installed in a wall-mount or short-depth rack?

A: Yes. At 236 mm deep, the AP4450A fits in short-depth two-post racks and wall-mount enclosures. Verify your enclosure's usable depth before ordering — some wall-mount cabinets have internal obstruction points shallower than the listed depth.

Q: Does the AP4450A include network management capabilities?

A: The evidence available does not confirm built-in network management or SNMP capabilities for the AP4450A. The unit features an LCD front panel for local status monitoring. Consult the manufacturer's full specification sheet to confirm whether a management card slot or network interface is supported.

Q: What is the operating temperature range for the AP4450A?

A: The AP4450A operates from -5°C to 45°C (23°F to 113°F) and stores from -25°C to 65°C (-13°F to 149°F). This range covers most controlled IDF, MDF, and edge-rack environments, including warmer hot-aisle conditions up to 45°C.

Jerry Tildsen
Jerry Tildsen

The AP4450A addresses a gap that catches a lot of smaller deployments off guard: you've installed a dual-corded server or storage appliance expecting redundant power, but everything is still plugged into a single PDU on a single branch circuit. This unit puts a real transfer switch between your two feeds and your load — when the primary input goes out of the 90–110V operating window, transfer happens automatically, with no operator required. For a 10-outlet, 1U form factor at 15A/120V, it's sized for exactly the kind of edge rack or IDF closet where budget constraints have historically pushed people toward single-feed PDUs and a prayer.

Technical Highlights:

  • 90–110V Operating Window: Tighter than some ATS units — if your facility has chronic voltage sag that regularly dips below 90V on either feed, the unit will transfer more frequently than expected. Confirm your supply voltage headroom before deploying in older buildings or industrial environments with heavy motor loads on the same panel.
  • 10 x NEMA 5-15R at 15A: Ten outlets across a single 15A feed works out to an average of 1.5A per device at full load — fine for network switches, NVRs, and edge compute nodes, but you'll hit the 12A continuous limit quickly if you mix in anything with a significant inrush load. Keep a running load calculation during rack design.
  • 1U / 432 × 236 × 44 mm: The 236 mm depth is the spec to check first. Many wall-mount enclosures list 300 mm usable depth but have cable management panels that reduce clearance. Measure the actual usable depth at the rail, not the cabinet spec sheet depth.

Deployment Considerations:

  • Both input feeds need to originate from genuinely independent sources — separate UPS units or separate utility feeds on separate panels — for the ATS to provide real redundancy. Two circuits from the same breaker panel on the same UPS output is not a redundant architecture; it's two paths to the same single point of failure.
  • The LCD front panel is local-only based on available specs. If your standard operating procedure requires remote power monitoring or SNMP alerting on source transfer events, verify whether the AP4450A supports a management card before ordering — this is not confirmed in the available evidence and may require a different model in the APC ATS family.

The AP4450A is the right fit for a network or security equipment rack that already has two independent 15A/120V feeds available and needs a clean, automatic transfer mechanism between them — specifically IDF closets, edge-compute nodes, and small surveillance NVR racks where downtime cost justifies the redundancy investment but the load profile doesn't demand 20A or 208V distribution.

Specifications
Input operation voltage (min: 90 V
Input operation voltage (max: 110 V
AC input frequency: 50 - 60 Hz
Input current: 15 A
Form factor: Rackmount
Rack capacity: 1U
Product colour: Black
Display: LCD
AC outlets quantity: 10 AC outlet(s)
AC outlet types: NEMA 5-15R
Operating temperature (T-T: -5 - 45 °C
Storage temperature (T-T: -25 - 65 °C
Operating relative humidity (H-H: 5 - 95%
Total carbon footprint (kg of CO2e: 505.72
Width: 432 mm
Depth: 236 mm
Height: 44 mm
Weight: 4.4 kg
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources