Altronix ALTX/AMAG 8DR/115V/PTC - T2AGK7F8SD
N 8-output power distribution module designed to efficiently distribute power from a central location to multiple surveillance or access control
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Altronix T2AGK78SD is a purpose-built 24VAC power distribution unit delivering 10A across 8 independently protected outputs — sized for multi-door AMAG access control installations where clean, code-compliant power matters as much as the hardware it feeds. At 240VA total capacity, this unit carries the load of a mid-size door controller deployment without relying on field-improvised power splits or daisy-chained supplies that introduce ground loops and void system warranties.
Engineered for the Altronix ALTX/AMAG platform, the T2AGK78SD sits in the category of access control power supplies where predictable voltage and per-output protection are the design criteria — not afterthoughts. If you've commissioning a multi-reader installation and need to budget your power distribution, start here.
The T2AGK78SD is designed for ALTX/AMAG multi-door access control systems operating on 24VAC. If your installation uses a different voltage (12VDC or 24VDC panels, for example), this is not the correct supply — verify your controller's input voltage requirement before ordering. For larger deployments requiring more than 8 outputs or higher total current, review the broader Altronix power distribution line for higher-capacity variants. When planning your power budget, account for mag-lock inrush (typically 2–3× steady-state current at energize) against the 10A total — eight fully loaded mag-lock outputs may approach the supply's ceiling under simultaneous door-release events.
A well-planned installation pairs this unit with a quality UPS or battery backup — Altronix offers integrated battery management options worth considering for any installation where door access must survive a mains outage. See the access control accessories category for compatible battery and enclosure options.
Q: What is the output voltage of the T2AGK78SD?
A: The T2AGK78SD outputs 24VAC across all 8 outputs. Total output capacity is 10A / 240VA.
Q: What type of overcurrent protection does the T2AGK78SD use?
A: PTC (Positive Temperature Coefficient) resettable protection is used on each output. PTC devices trip on overcurrent and reset automatically once the fault clears — no fuse replacement is needed.
Q: How many doors can the T2AGK78SD support?
A: The unit provides 8 independent outputs. In a one-output-per-door architecture, it supports up to 8 doors. Actual door count depends on the power draw of each lock and reader; verify your per-door load against the 10A total before finalizing your design.
Q: What is the input voltage requirement for the T2AGK78SD?
A: The T2AGK78SD requires 115VAC input — standard North American mains. No special transformer or circuit is required beyond a standard 15A or 20A branch circuit.
Q: Is the T2AGK78SD compatible with systems other than AMAG?
A: The T2AGK78SD is factory-configured for the Altronix ALTX/AMAG platform. It delivers 24VAC, which is compatible with other 24VAC access control hardware in principle, but the unit is optimized and warranted for use within the ALTX/AMAG ecosystem. Consult your system documentation before using it with other controllers.
Q: Can I expand beyond 8 outputs if my installation grows?
A: The T2AGK78SD is fixed at 8 outputs and 10A. For larger installations, Altronix offers higher-output power distribution units in the same ALTX series — select the variant that matches your door count and total current budget.

The T2AGK78SD's PTC resettable protection per output is the spec I look at first on any Altronix access control supply — it means a wiring fault at one door doesn't take down adjacent circuits and doesn't require a technician on-site to reset. For an 8-door AMAG deployment, that operational resilience justifies the unit over a cheaper generic supply almost immediately.
Technical Highlights:
Deployment Considerations:
The T2AGK78SD is the right unit for an AMAG-based 8-door deployment where you need clean per-circuit isolation and self-recovering fault protection — a corporate campus secondary entrance cluster or a mid-size commercial building's interior door suite are the deployments where this unit earns its place.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Altronix products? Shop the full Altronix catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price