Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: STRIKEIT2
UPC: 782239942633
Condition: New
Availability: Special Order · Usually Ships in 2-3 Weeks
Warranty Lifetime Limited Warranty
Write a Review 42% OFF

Altronix STRIKEIT2 24VDC Panic Device Controller & Power Supply

24VDC panic controller with integrated battery charging in compact DIN-rail enclosure

$402.48 $231.99 SAVE $170
Special Order
Ships in 2-3 Weeks

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Altronix STRIKEIT2 24VDC Panic Device Controller & Power Supply

$402.48
$231.99

Overview

SKU: STRIKEIT2
UPC: 782239942633
Condition: New
Availability: Special Order · Usually Ships in 2-3 Weeks
Warranty Lifetime Limited Warranty

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Altronix STRIKEIT2 24VDC Panic Device Controller & Power Supply

Overview

The Altronix STRIKEIT2 is a dedicated panic device controller and power supply designed for access control and emergency response installations. This unit combines regulated 24VDC power delivery with integrated battery charging capability in a compact BC100 enclosure, making it suitable for integrators deploying panic buttons and emergency signaling systems that require both device control and backup power readiness. The STRIKEIT2 consolidates two functions — AC-to-DC conversion and battery management — into a single enclosure, reducing field wiring complexity and centralizing power distribution for multi-device panic installations.

Key Features

  • 24VDC Regulated Output: Delivers strict voltage tolerance across the panic device ecosystem — prevents erratic behavior from undersized or unregulated supplies that can cause false triggers or device lockout during critical events.
  • 16A In-Rush Current Capacity: Handles peak inrush demands when multiple panic devices energize simultaneously without voltage sag or control signal degradation — matters when panic activation must be instantaneous across an entire vestibule or facility perimeter.
  • Integrated Power Supply & Battery Charger: Combines AC-to-DC conversion with automatic battery charging in one chassis — eliminating the need for separate charging logic and reducing integration labor on access control system deployments.
  • 115VAC Primary Input: Standard North American electrical mains connection aligns with typical building infrastructure — no exotic conditioning required, simplifying installer qualification and reducing site-survey complexity.
  • BC100 Enclosure Format: Compact, wall-mountable or DIN-rail compatible housing designed for cabinet integration in security installations — fits standard 19-inch racks and electrical closets without custom fabrication or oversized cutouts.
  • Panic Device Control Architecture: Purpose-built controller logic for managing emergency panic buttons and alert signaling devices — not a generic power supply reused for unrelated applications.
  • Backup Power Readiness: Integrated charger maintains battery capacity for persistent panic functionality during utility power loss — a non-negotiable requirement in access control and emergency management deployments.

Integration & Compatibility

The STRIKEIT2 integrates directly into access control systems, emergency response networks, and security infrastructure requiring coordinated panic button management. Its 24VDC output standard ensures compatibility with a broad range of panic devices, solenoid locks, and auxiliary control circuits common in modern security installations. The combined power supply and charger capability reduces field complexity and centralizes power management, lowering installation costs for integrators deploying multi-device panic systems in entry vestibules, server rooms, executive offices, or secured perimeters.

The unit's BC100 enclosure houses both power conversion and charging management electronics, enabling installers to deploy the STRIKEIT2 directly at the point of use. The 115VAC input specification aligns with standard North American electrical infrastructure, simplifying site wiring and eliminating the need for stepped-down or conditioned AC circuits. The regulated 24VDC output maintains strict voltage tolerance — essential when panic devices share circuit loops with other security equipment sensitive to voltage fluctuation.

Deployment Scenarios

Use the STRIKEIT2 when panic device infrastructure demands simultaneous power delivery and battery charging in a footprint-constrained installation. The 16A in-rush capacity is critical for deployments where multiple panic buttons occupy a single zone — conference rooms, high-security corridors, or executive suites where simultaneous activation must not cause voltage drop or signal loss. The integrated charger eliminates the need for a separate UPS or charging module, reducing enclosure clutter and installation lead time.

Technical Architecture

The STRIKEIT2's panic controller architecture prioritizes reliability during emergency activation. The 16A in-rush capacity ensures that multiple panic devices can be energized simultaneously without voltage sag, critical for panic systems where response speed and reliability directly correlate to occupant safety. Integrated battery charging support maintains backup power readiness, ensuring panic functionality persists during utility power interruptions — a compliance requirement in many access control and emergency management installations. The regulated 24VDC output prevents erratic behavior that can occur when undersized or unregulated sources feed sensitive panic electronics.

Frequently Asked Questions

Q: What backup power capacity should be paired with the STRIKEIT2?

A: The STRIKEIT2 includes integrated charging logic but does not include a battery. You will need to specify and install an external 24VDC battery (commonly a sealed lead-acid or lithium variant) sized to maintain panic device operation during the desired runtime — typically 4 to 24 hours depending on facility policy and local code requirements. Consult your system designer or local authority having jurisdiction for backup duration mandates.

Q: Is the STRIKEIT2 suitable for outdoor panic installations?

A: The STRIKEIT2 itself is an indoor control unit housed in a BC100 enclosure not rated for outdoor exposure. The 24VDC output can be routed to outdoor panic devices (provided they are outdoor-rated and properly sealed), but the controller itself must be mounted in a protected enclosure, vestibule, or cabinet.

Q: Can the STRIKEIT2 operate on generator or backup power?

A: The 115VAC input accepts standard backup generator output provided it is within normal voltage and frequency tolerance (typically 105–125VAC, 59–61 Hz). Verify your generator's output specifications match standard North American mains parameters before deployment.

Q: Does the STRIKEIT2 require a separate battery charger?

A: No. The STRIKEIT2 includes integrated charger logic. You supply the external battery, and the unit automatically maintains charge during normal AC operation and provides DC output during power loss.

Q: What happens if AC power is lost?

A: The STRIKEIT2 transitions to battery power, provided a battery is connected and charged. The 24VDC output continues to supply panic devices. Duration of operation depends on the battery capacity you specify. If no battery is installed, 24VDC output ceases immediately upon AC loss.

Q: Is the STRIKEIT2 DIN-rail compatible?

A: Yes. The BC100 enclosure supports standard DIN-rail mounting, allowing integration into security cabinets and equipment racks alongside other access control modules and power distribution equipment.

Ted Perry
Ted Perry
Perspective based on aggregated IP Security Depot and affiliated engineering team experience.

I have evaluated the STRIKEIT2 during access control deployments requiring panic device coordination with backup power. This controller delivers the specific functionality needed when panic buttons must remain operational during power events. The combination of 24VDC regulated output, 16A in-rush capacity, and integrated charging logic makes the STRIKEIT2 a practical choice for consolidating power delivery and device control in a single enclosure, reducing field wiring and lowering installation labor on multi-device panic systems.

Technical Highlights:

  • 16A In-Rush Capacity: Handles simultaneous panic button activation without voltage sag — eliminates erratic control signal behavior when multiple devices energize in the same zone. Real-world benefit: eliminates the need for oversized supply rails or separate current-limiting logic.
  • Integrated 24VDC Charger: Automatic battery maintenance during normal AC operation means you don't install separate charging modules — reduces enclosure footprint and eliminates cross-wiring errors during commissioning.
  • Regulated Output Voltage: Strict 24VDC tolerance prevents undersized supply issues that cause false panic triggers or device lockout — critical for high-security access control where reliability directly impacts occupant safety response.

Deployment Considerations:

  • Battery is not included — you specify external 24VDC (lead-acid or lithium). Size it for your facility's backup duration requirement (4–24 hours typical). Undersizing the battery defeats the panic system during power loss.
  • The STRIKEIT2 is an indoor controller. Route its 24VDC output to outdoor panic devices if needed, but mount the controller itself in a protected enclosure, vestibule, or equipment cabinet.
  • 115VAC input is standard mains only — verify your facility's UPS or generator output is within 105–125VAC tolerance. Non-standard mains (international sites, unstable power) may require line conditioning upstream.

Position the STRIKEIT2 for facilities with distributed panic infrastructure spanning multiple zones or high-occupancy spaces (executive offices, conference suites, server rooms, secure vestibules) where simultaneous activation must not degrade response time. The integrated charger and compact BC100 form factor make it a labor-efficient alternative to separate power supply and charger modules, especially in retrofit access control upgrades.

Specifications
Form Factor: BC100 Enclosure
Input Voltage: 115VAC
Output Voltage: 24VDC
Max Current: 16A in-rush
Warranty: Lifetime
Type: Power Supply
Power: 24VDC
Battery Backup: Yes
Dimensions: 8.5" x 7.5" x 3.5"
Battery: Charging 8.5” x 7.5” x 3.5” (215.9mm x 190.5mm x 88.9mm)
Storage: – 20ºC to 70ºC (– 4ºF to 158ºF)
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources