Vertiv Aisle Cntainment Accy 2UX1FT Height Adpt - VC-AC-0006
2U height adapter designed to integrate 1-foot wide aisle containment modules into existing data center infrastructure
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv VC-AC-0008 is a 2U x 600mm height adapter designed to close dimensional gaps in aisle containment systems. In hot-aisle and cold-aisle containment deployments, even a small unmated gap between containment panels and adjacent rack infrastructure bleeds conditioned air directly into the return path — undermining the entire thermal separation the enclosure was installed to achieve. The VC-AC-0008 (often searched as VC AC 0008) addresses that problem as a purpose-built accessory, letting you adapt containment height to match the actual rack elevation without resorting to improvised blocking materials that degrade over time.
This is a single-unit accessory. Each package contains one adapter sized at 2U in height and 600mm in width — matching the standard 600mm rack column footprint common in two-post and four-post open-frame and enclosed rack systems. If you are specifying a containment row with mixed-height racks or transitioning between standard 42U and taller 48U or 52U cabinets, the VC-AC-0008 fills the height delta in 2U increments, keeping the containment plane continuous from floor to ceiling or from canopy to rack top rail.
The VC-AC-0008 is specified for use with Vertiv aisle containment systems where 600mm-wide rack columns are deployed. Confirm your rack column width before ordering — 800mm rack environments require a different adapter width. The 2U height dimension is standardized (1U = 1.75 inches / 44.45mm), so a single VC-AC-0008 fills 88.9mm (approximately 3.5 inches) of vertical gap. For deployments using Vertiv's SmartRow or VR-series rack lines, verify the containment canopy attachment points are compatible with the height adapter profile. When planning a data center power and cooling refresh that includes new containment infrastructure, account for the height adapter quantity in your BOM at the cabinet-layout stage — it is easier to order with the primary containment components than to source them separately after installation.
Q: What rack width is the VC-AC-0008 designed for?
A: The VC-AC-0008 is sized for 600mm-wide rack columns. If your deployment uses 800mm racks, you will need a different adapter width — verify your rack column dimension before ordering.
Q: How much vertical height does one VC-AC-0008 unit cover?
A: One unit covers 2U of vertical height. At the standard 1U = 44.45mm, that equals approximately 88.9mm (3.5 inches) of gap fill per adapter. Multiple units can be stacked to address larger gaps.
Q: How many adapters come in one package?
A: One adapter per package. Order the exact quantity your row layout requires.
Q: Can the VC-AC-0008 be used with non-Vertiv aisle containment systems?
A: The VC-AC-0008 is a Vertiv-branded accessory engineered to fit Vertiv aisle containment geometry. Compatibility with third-party containment systems is not confirmed by the manufacturer — measure attachment profiles carefully before specifying outside a Vertiv ecosystem.
Q: Why does closing a 2U gap matter for thermal efficiency?
A: An unsealed 2U x 600mm gap in a containment enclosure creates an open bypass path where hot return air mixes with cold supply air. This reduces the temperature differential available to your CRAC/CRAH units, increasing compressor load and reducing the effective cooling capacity of the row. Sealing that gap restores the containment system's designed thermal separation.

The VC-AC-0008 is a straightforward but operationally important accessory — it fills a 2U x 600mm vertical gap in a Vertiv aisle containment deployment, and that specific dimension matters more than it looks on a BOM. A single unsealed 2U gap at 600mm width is enough open area to measurably reduce the hot/cold air temperature differential in a contained row, which means your cooling infrastructure is working harder than the containment spec said it would.
Technical Highlights:
Deployment Considerations:
This adapter is the right call for data center rows where mixed-height racks create incremental height mismatches at the containment canopy line — specifically in 600mm-column environments where you need a manufacturer-matched solution rather than improvised blocking that degrades the containment seal over time.