Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FAP6WGVLDLCZ 6-Position Keyed Duplex LC OM4 Fiber Adapter Panel

Overview

The Panduit FAP6WGVLDLCZ is a 6-position keyed fiber adapter panel insert finished in G-Violet — the industry-standard color designation for OM4 multimode fiber. Designed for installation into Panduit's modular patch panel frames, the FAP6WGVLDLCZ provides six duplex LC adapter positions in a compact, keyed form factor that physically prevents cross-connection with non-keyed or differently-keyed assemblies. If your backbone infrastructure is OM4 and you're building out high-density MDA or IDA zones, the G-Violet color coding gives technicians an immediate, unambiguous visual reference at the patch field — no label dependency required.

Key Features

  • 6-Position Keyed Configuration: Six duplex LC adapter positions in a single panel module. The keyed design mechanically restricts which fiber connectors can mate, reducing the risk of incorrect cross-connects in mixed-fiber environments where OM3 and OM4 pathways share the same patch field.
  • G-Violet Color Coding: G-Violet is the TIA/EIA-recognized color for OM4 multimode fiber. At a glance, technicians can identify the fiber type without referencing documentation — a real operational advantage in high-density cabling environments and during after-hours troubleshooting or adds/moves/changes.
  • Modular Panel Insert Design: The FAP6WGVLDLCZ is built as an insert for Panduit's fiber adapter panel frames, allowing mixed port-type configurations within a single rack unit. You can combine LC, SC, or other adapter modules in the same frame to match your actual infrastructure without committing to a single-type panel.
  • Duplex LC Adapter Interface: LC duplex connectors are the dominant interface in modern 10GbE, 40GbE, and OM4-based backbone runs. This panel directly terminates those runs without adapters or pigtail conversions, keeping insertion loss predictable and minimizing connection points in the link budget.

Integration and Compatibility

The FAP6WGVLDLCZ is designed for use within Panduit's fiber adapter panel (FAP) frame ecosystem. Verify frame compatibility with your specific Panduit FAP chassis model before ordering — the keyed insert format requires a matching frame that accepts modular inserts. This adapter panel is suited for OM4 multimode fiber terminations; the G-Violet designation is specific to OM4 and should not be used to terminate OM3, OS1, or OS2 fiber without re-labeling, as color coding is a primary identification method for technicians working the panel. For structured cabling deployments running OM4 backbone links, pairing this panel with Panduit's matching fiber optic cables and assemblies maintains manufacturer ecosystem consistency. Review the Panduit catalog for compatible frame options, bulk fiber, and patch cord assemblies. Integrators managing mixed-generation infrastructure may also want to reference a fiber optic cable selection guide to confirm OM4 reach and bandwidth specifications before finalizing panel placement.

Frequently Asked Questions

Q: What fiber type is the FAP6WGVLDLCZ designed for?

A: The G-Violet color designation identifies this panel as intended for OM4 multimode fiber. OM4 supports higher bandwidth and longer reach than OM3 at 10GbE and above, and the G-Violet color is the TIA-recognized identifier for OM4 in structured cabling installations.

Q: What connector type does the FAP6WGVLDLCZ use?

A: The FAP6WGVLDLCZ uses duplex LC adapters. LC duplex is the standard interface for modern 10GbE and higher-speed multimode applications and is widely used in MDA/IDA patch fields.

Q: How many ports does the FAP6WGVLDLCZ provide?

A: It provides 6 keyed adapter positions, each supporting a duplex LC connection — 12 fiber strands total in a single modular insert.

Q: What does the keyed design on the FAP6WGVLDLCZ prevent?

A: The keyed adapter format creates a mechanical restriction that prevents non-keyed or differently-keyed connectors from mating with the panel. This reduces incorrect cross-connections in environments where multiple fiber types or pathways share the same patch field.

Q: Is the FAP6WGVLDLCZ compatible with all Panduit FAP frames?

A: The FAP6WGVLDLCZ is a modular insert for Panduit's FAP frame system. Compatibility depends on the specific frame model. Confirm your chassis accepts modular 6-position inserts before ordering.

Marty Allison
Marty Allison

The FAP6WGVLDLCZ is one of those parts that does exactly one job and does it without drama — six keyed duplex LC positions in G-Violet, ready to drop into a Panduit FAP frame for OM4 termination. If you're wiring a new MDA or expanding an existing IDA in a facility running OM4 backbone, this is the panel insert that keeps your color discipline intact without compromise.

Technical Highlights:

  • 6-Position Keyed Format: Six duplex LC adapter positions with physical keying — mechanical enforcement of fiber-type segregation where OM3, OM4, and singlemode share the same patch field.
  • G-Violet OM4 Designation: G-Violet is not a cosmetic choice — it's a TIA-codified identifier. Every technician working the panel can read fiber type without pulling documentation, which matters at 2 AM during an incident response.
  • Modular Insert Architecture: Drops into Panduit FAP frames alongside other adapter types, giving you mixed-fiber patch fields in a single RU without forcing a single-connector-type commitment across the whole panel.

Deployment Considerations:

  • Confirm your FAP frame explicitly accepts 6-position modular inserts — Panduit's frame lineup spans multiple form factors and not all accept the same insert configurations.
  • Do not use G-Violet keyed panels to terminate OM3 or singlemode fiber, even temporarily. Color coding is the primary identification mechanism for technicians and misuse creates the exact cross-connect risk the keyed design is meant to prevent.

Best fit for enterprise data center MDA/IDA buildouts and campus backbone projects where OM4 is the standard and long-term color discipline across the patch field is a requirement, not an afterthought.

Specifications
Product Name: Panduit FAP6WGVLDLCZ
Keyed Type: 6 Position
Color: G-Violet
Q&A
Reviews

Panduit 6 POSITION KEYED (G-VIOLET) DUP - FAP6WGVLDLCZ

$226.80
$136.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources