Image coming soon
Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FRZUP77Y002F051 OM4 24-Fiber PanMPO Plenum Trunk Cable Assembly

Overview

The Panduit FRZUP77Y002F051 is a factory-terminated 24-fiber OM4 multimode trunk assembly built for enterprise data rooms and structured cabling closets where density, polarity discipline, and optical margin matter. At 51 ft, it spans rack-to-rack distances that patch cords can't cover and that field-spliced cable shouldn't. PanMPO female connectors on both ends with 24-inch breakouts make this a workhorse in high-density fiber distribution pathways — eliminating field-termination variability at the connection points that matter most.

This assembly targets installations standardizing on Panduit fiber infrastructure, where connector consistency, polarity management, and jacket compliance need to be locked in before the cable ever leaves the box. It is not a commodity patch cord — it is a precision-manufactured interconnect for teams that cannot afford troubleshooting optical margin issues after installation.

Key Features

  • OM4 50/125 µm Multimode Construction: OM4 supports 40GbE up to 150 m and 100GbE up to 100 m — at 51 ft you are well within budget for both, giving room to absorb connector losses and still close the link comfortably in backbone and aggregation roles.
  • 24-Fiber Breakout Design: Twenty-four fibers in a single pull means fewer cable runs, fewer penetrations, and a cleaner pathway through conduit and cable managers. The 24-inch breakout length gives technicians enough slack to fan out to individual adapters without forcing awkward bend radii at the cassette face.
  • PanMPO Female Connectors on Both Ends: Female MPO connectors mate directly with male-pinned cassettes and panels — the standard configuration in most modular fiber cassette and enclosure systems. No gender adapters, no added insertion loss, no guessing at field end.
  • Polarity B Configuration: Polarity B pairs fiber 1 at one end to fiber 1 at the other — the straight-through method used widely in engineered structured cabling plants. If your plant is designed around Polarity B, this cable drops in without rejiggering the channel map.
  • Plenum (CMP) Jacket Rating: The aqua plenum jacket is code-compliant for air-handling spaces — dropped ceilings, raised floors, and any pathway where air circulates freely for HVAC. Running riser-rated cable in plenum spaces is a code violation; this assembly eliminates that risk for runs through those zones.
  • Optimized Insertion Loss Design: Factory-terminated assemblies from Panduit's PanNet line are built to tighter insertion loss tolerances than field-polished connectors. In a multi-hop fiber channel, every connector adds loss — a well-characterized, optimized-loss assembly keeps your end-to-end budget predictable and leaves margin for aging and environmental effects.
  • 51 ft Fixed Length: Matched to rack-to-rack spans that exceed standard patch cord reach but don't justify a full trunk reel. Pre-cut length means no coiled excess to manage in cable trays and no guessing on pull tension over a longer run.
  • Aqua Jacket Color: Aqua is the industry-standard color code for OM3 and OM4 multimode fiber. In a mixed-fiber environment (single-mode and multimode), jacket color is your first line of defense against mis-patching — aqua versus yellow versus orange is visible across a crowded patch panel without pulling connectors.

Integration & Compatibility

The FRZUP77Y002F051 integrates into any MPO-based structured cabling system using Polarity B. It is designed for use with Panduit's modular fiber cassette enclosures and PanNet distribution panels, but the standard PanMPO female connector is physically and optically compatible with third-party MPO-accepting cassettes and breakout modules. Verify polarity convention (A, B, or C) against your installed plant before ordering — a polarity mismatch in an MPO channel requires an additional polarity-correcting module or a different assembly, not a re-pull. OM4 fiber is backward-compatible with OM3 transceivers and links, though at reduced distance. It is not compatible with single-mode (OS1/OS2) transceivers. For teams sourcing fiber trunk assemblies across a full data room buildout, Panduit's PanNet line offers matching assemblies in varying fiber counts and lengths to complete the plant without mixing vendor termination styles.

Frequently Asked Questions

Q: What polarity method does the FRZUP77Y002F051 use?

A: This assembly uses Polarity B, which maps fiber 1 at one end to fiber 1 at the other end (straight-through). Confirm your MPO plant's polarity convention before deployment — mixing polarity methods without a correcting module will break the channel.

Q: Is the FRZUP77Y002F051 suitable for 100GbE links?

A: Yes. OM4 50/125 µm multimode fiber supports 100GbE (100GBASE-SR10) up to 100 m. At 51 ft this assembly is well within that distance budget, with ample margin for connector and splice losses in a typical backbone channel.

Q: Can I use this cable in a plenum ceiling space?

A: Yes. The FRZUP77Y002F051 carries a plenum (CMP) jacket rating, which is required by code in air-handling spaces such as dropped ceilings and raised floors used for HVAC return air. Riser-rated cable cannot be substituted in those spaces.

Q: What connector gender is on each end?

A: Both ends terminate with PanMPO female connectors. These mate with male-pinned MPO adapters, cassettes, and panels — the standard configuration for most modular fiber distribution systems. No gender adapters are required in a standard installation.

Q: Is this assembly compatible with third-party MPO cassettes and panels?

A: The PanMPO female connector follows standard MPO/MTP mechanical and optical specifications and will physically mate with compliant third-party hardware. Optical performance guarantees apply to Panduit-to-Panduit connections; verify insertion loss budgets independently if mixing with other vendors' cassettes.

Q: What does 'optimized insertion loss' mean in practice?

A: It means the connectors are polished and characterized at the factory to tighter loss tolerances than typical field-terminated connectors. In a multi-hop fiber channel where losses stack across each mated pair, a lower and more consistent per-connector loss gives you more usable optical budget — reducing the risk of intermittent link errors as the plant ages.

James Everett
James Everett

The detail I keep coming back to on the FRZUP77Y002F051 is the 24-inch breakout — it sounds minor until you're actually at a cassette face trying to dress 24 fibers without kinking them below minimum bend radius. That extra slack is engineered in, not an afterthought, and it's what separates a factory assembly like this from anything you'd build in the field on a deadline.

Technical Highlights:

  • OM4 50/125 µm Core: Full OM4 headroom puts 40GbE and 100GbE comfortably in range at 51 ft — you're using maybe 15% of the rated distance budget, which means this channel will survive multiple future transceiver generations without a re-pull.
  • 24-Fiber Count at 51 ft: Twenty-four fibers in a single factory-terminated pull versus 12 individual patch cords across the same route — half the cable management load, half the panel entries, and a single provenance document if you ever need to troubleshoot.
  • Polarity B, Female-Female: Straight-through polarity with female PanMPO ends means this drops into a standard male-pinned modular cassette system with zero polarity adapters and a fully predictable channel map — the kind of thing that matters when you're commissioning 48 ports in an afternoon.

Deployment Considerations:

  • Verify your existing plant polarity before ordering. If your cassettes are wired for Polarity A or C, this assembly creates a mis-mapped channel — you'll need a polarity-correcting module, not a re-pull, but it's a step you don't want to discover on installation day.
  • The plenum jacket earns its keep in air-handling spaces, but plenum-rated cable is stiffer than riser at cold temperatures — route it early in the installation sequence before the ceiling fills up, and leave room for the 24-inch breakout to fan naturally without forcing the connectors against an enclosure wall.

This assembly is the right specification for enterprise MDF-to-IDF backbone links in commercial buildings with plenum ceiling pathways — specifically where the plant is designed on Polarity B and the teams commissioning it need a zero-field-termination, provenance-documented run from patch panel to patch panel.

Specifications
Fiber Type: OM4 Multimode
Core Cladding: 50/125 µm
Fiber Count: 24-Fiber
Cable Length: 51 ft
Connector Type: PanMPO Female
Jacket Type: Plenum
Jacket Color: Aqua
Insertion Loss: Optimized
Q&A
Reviews
Have Questions?

Panduit 51FT OM4 24-FB ICT POL B OPT IL - FRZUP77Y002F051

$1,634.82
$963.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources