CyberPower NEMA 5-15R (2 Front / 10 Rear) 19" 1U RM or 0U VM
Professional-grade 1U rackmount surge protector with 3600 joules protection and 12 outlets
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The CyberPower PDU15B6F12R is an 18-outlet basic power distribution unit designed for surveillance, access control, and network infrastructure deployments where you need to distribute power across a dense rack or wall-mounted server cluster without filtering or surge conditioning. This 1U rackmount unit (also installable as 0U vertical or under-counter wall mount) provides six front outlets and twelve rear outlets, all NEMA 5-15R receptacles rated for 100–125V at 15A input, derated to 12A continuous output. The 15-foot power cord and metal housing make it suitable for permanent installation in server rooms, network closets, and surveillance head-end environments where rack density and outlet count matter more than conditioning.
The PDU15B6F12R integrates with any equipment using standard NEMA 5-15 plugs: IP cameras with external power supplies, 24V or 12V power injectors for PoE switches, NVR systems, access control panels, and network switches. Mount it in a 19-inch rack alongside your switch, NVR, and UPS, or install it on a wall in a surveillance closet to feed power to multiple outdoor cameras via the rear outlets. For surveillance deployments with redundancy, pair two units in parallel off separate UPS batteries — each PDU can then feed a different set of cameras, so a single-unit failure doesn't black out all video. Because this is a passive PDU (no filtering), position surge protection or UPS conditioning upstream; do not rely on the PDU15B6F12R alone to shield sensitive NVR storage or analytics hardware from power anomalies.
The PDU15B6F12R arrives with a 15-foot NEMA 5-15P power cord, internal cord retention tray for cable management, and external site ground pin. Mounting hardware for both 1U rackmount and wall-mount installation is included.
Q: Can I wall-mount the PDU15B6F12R outside of a rack?
A: Yes. In addition to 1U rackmount, the PDU15B6F12R supports 0U vertical mounting, under-counter installation, and wall mounting. This makes it suitable for surveillance closets, equipment shelves, and networked camera power distribution points that aren't in a traditional server rack.
Q: What's the maximum power draw on the PDU15B6F12R?
A: The unit is derated to 12A continuous output at 100–125V, meaning approximately 1,440 watts max (12A × 120V). If you load it beyond 12A sustained, the 15A main breaker will trip. Plan your outlet load carefully: a typical NVR draws 2–4A, an access control panel 1–2A, and a PoE injector 3–8A depending on camera count.
Q: Does the PDU15B6F12R include surge protection?
A: No. This is a basic, unfiltered PDU with no surge suppression or line conditioning. It passes power directly through. If your facility's power grid is unstable or lightning-prone, install a UPS or surge protector upstream of the PDU to protect your NVR and camera infrastructure.
Q: What's the warranty on the PDU15B6F12R?
A: Limited Lifetime Warranty covering defects in materials and workmanship under normal use.
Q: Can I daisy-chain multiple PDU15B6F12R units?
A: Yes, but not recommended for surveillance deployments. Multiple PDUs on a single branch circuit can exceed the 15A input rating and trip the breaker. Instead, feed each PDU from a separate 15A circuit. This also improves fault isolation: if one PDU or its connected equipment fails, the other PDU outlets remain powered.
Q: Is the PDU15B6F12R NDAA compliant?
A: There is no NDAA Section 889 restriction on basic passive power distribution units. The PDU15B6F12R is a commodity component with no controlled software or wireless capability, so it carries no federal procurement restriction.

I spec the PDU15B6F12R into surveillance head-end deployments where you've got a mixed power load — NVRs, network switches, PoE injectors, and access control gear all sharing a single 19-inch rack. The 18-outlet split (6 front, 12 rear) is the key spec here: front outlets handle your high-touch devices (NVRs, injectors you service regularly), and rear outlets handle your permanent mounts (switch power, access panel backup supply). The 15-foot cord length saves you from wrestling with extension reels, and that external site ground pin eliminates ground-loop hum on serial control lines to your access control panels — I've seen that alone solve intermittent faults in older installations.
Technical Highlights:
Deployment Considerations:
This PDU is the right call for fixed surveillance infrastructure where you control the upstream power quality and want simplicity over conditioning. Pair it with a UPS on each PDU for redundancy, and you've got a rock-solid backbone for distributed NVR and access control systems in multi-site deployments.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more CyberPower products? Shop the full CyberPower catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price