Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

CyberPower PDU15B6F12R 18-Outlet Basic Power Distribution Unit

Overview

The CyberPower PDU15B6F12R is an 18-outlet basic power distribution unit designed for surveillance, access control, and network infrastructure deployments where you need to distribute power across a dense rack or wall-mounted server cluster without filtering or surge conditioning. This 1U rackmount unit (also installable as 0U vertical or under-counter wall mount) provides six front outlets and twelve rear outlets, all NEMA 5-15R receptacles rated for 100–125V at 15A input, derated to 12A continuous output. The 15-foot power cord and metal housing make it suitable for permanent installation in server rooms, network closets, and surveillance head-end environments where rack density and outlet count matter more than conditioning.

Key Features

  • 18 Outlets (6 Front / 12 Rear): Covers 18 devices per PDU — ideal for powering multiple NVRs, IP cameras with power injectors, network switches, or access control panels in a single rack without daisy-chaining. Front access avoids cable tangle on the back panel.
  • 1U Rackmount Form Factor: Mounts into a standard 19-inch equipment rack, consuming just 1.75 inches of vertical space. If rack space is unavailable, the PDU15B6F12R also supports 0U vertical mounting on a wall or under-counter installation, giving you flexibility in non-traditional server closets.
  • 15A Circuit Breaker with 12A Derated Output: The 15A main breaker protects against overload, while the derated 12A continuous output rating ensures thermal headroom during 24/7 operation — critical for surveillance environments where equipment runs nonstop. This prevents nuisance breaker trips on marginally loaded circuits.
  • Unfiltered Pass-Through Design: This is a basic PDU, not a filtered or surge-suppressed unit. Power flows directly from the inlet to the outlets without conditioning. For surveillance cameras, NVRs, and network equipment, this means lower cost and simpler serviceability, but no protection against incoming line noise or power spikes — keep surge protection at the facility level if your grid is unstable.
  • 15-Foot AC Cord with Retention Tray: Long cord reaches from distant breaker panels or UPS units without extension reels. The included cord retention tray keeps the cable organized and prevents accidental disconnection — important in busy server closets where people work near power cables.
  • Metal Housing and External Site Ground Pin: Rugged all-metal construction withstands rack-mount vibration and handling. The external site ground pin provides a dedicated earth reference for sensitive equipment (NVRs, access control panels) that requires clean ground reference — eliminates ground loops that can introduce video hum or intermittent faults on serial connections.
  • 100–125V Input / Output with 50/60 Hz: Works with standard North American single-phase power. The stable input and passthrough output (no step-up/step-down) preserve your facility's power quality without introducing transformer noise.
  • Operating Range 32–95°F, 0–95% Humidity (Non-Condensing): Rated for indoor server rooms and climate-controlled surveillance closets. The wide humidity tolerance handles seasonal swings in unsealed equipment rooms, but condensation is a no-go — ensure your space has adequate ventilation.
  • UL62368, UL60950-1, and RoHS Compliance: Meets North American electrical safety and EU restriction-of-hazardous-substances standards. Important for insurance and code compliance in commercial installations.
  • Limited Lifetime Warranty: Covers defects in materials and workmanship for the life of the product under normal use — a significant assurance for permanently installed infrastructure.

Integration & Compatibility

The PDU15B6F12R integrates with any equipment using standard NEMA 5-15 plugs: IP cameras with external power supplies, 24V or 12V power injectors for PoE switches, NVR systems, access control panels, and network switches. Mount it in a 19-inch rack alongside your switch, NVR, and UPS, or install it on a wall in a surveillance closet to feed power to multiple outdoor cameras via the rear outlets. For surveillance deployments with redundancy, pair two units in parallel off separate UPS batteries — each PDU can then feed a different set of cameras, so a single-unit failure doesn't black out all video. Because this is a passive PDU (no filtering), position surge protection or UPS conditioning upstream; do not rely on the PDU15B6F12R alone to shield sensitive NVR storage or analytics hardware from power anomalies.

What's in the Box

The PDU15B6F12R arrives with a 15-foot NEMA 5-15P power cord, internal cord retention tray for cable management, and external site ground pin. Mounting hardware for both 1U rackmount and wall-mount installation is included.

Frequently Asked Questions

Q: Can I wall-mount the PDU15B6F12R outside of a rack?

A: Yes. In addition to 1U rackmount, the PDU15B6F12R supports 0U vertical mounting, under-counter installation, and wall mounting. This makes it suitable for surveillance closets, equipment shelves, and networked camera power distribution points that aren't in a traditional server rack.

Q: What's the maximum power draw on the PDU15B6F12R?

A: The unit is derated to 12A continuous output at 100–125V, meaning approximately 1,440 watts max (12A × 120V). If you load it beyond 12A sustained, the 15A main breaker will trip. Plan your outlet load carefully: a typical NVR draws 2–4A, an access control panel 1–2A, and a PoE injector 3–8A depending on camera count.

Q: Does the PDU15B6F12R include surge protection?

A: No. This is a basic, unfiltered PDU with no surge suppression or line conditioning. It passes power directly through. If your facility's power grid is unstable or lightning-prone, install a UPS or surge protector upstream of the PDU to protect your NVR and camera infrastructure.

Q: What's the warranty on the PDU15B6F12R?

A: Limited Lifetime Warranty covering defects in materials and workmanship under normal use.

Q: Can I daisy-chain multiple PDU15B6F12R units?

A: Yes, but not recommended for surveillance deployments. Multiple PDUs on a single branch circuit can exceed the 15A input rating and trip the breaker. Instead, feed each PDU from a separate 15A circuit. This also improves fault isolation: if one PDU or its connected equipment fails, the other PDU outlets remain powered.

Q: Is the PDU15B6F12R NDAA compliant?

A: There is no NDAA Section 889 restriction on basic passive power distribution units. The PDU15B6F12R is a commodity component with no controlled software or wireless capability, so it carries no federal procurement restriction.

Jerry Tildsen
Jerry Tildsen

I spec the PDU15B6F12R into surveillance head-end deployments where you've got a mixed power load — NVRs, network switches, PoE injectors, and access control gear all sharing a single 19-inch rack. The 18-outlet split (6 front, 12 rear) is the key spec here: front outlets handle your high-touch devices (NVRs, injectors you service regularly), and rear outlets handle your permanent mounts (switch power, access panel backup supply). The 15-foot cord length saves you from wrestling with extension reels, and that external site ground pin eliminates ground-loop hum on serial control lines to your access control panels — I've seen that alone solve intermittent faults in older installations.

Technical Highlights:

  • 12A Derated Output on 15A Breaker: Gives you 1,440W of continuous capacity without nuisance trips. That's enough for a typical 16-channel NVR (3–4A) plus a 24-port PoE switch (5–8A) plus two access control panels (1–2A each) without hitting the limiter. The deration is intentional — it keeps thermal margins safe during 24/7 surveillance operation.
  • Unfiltered Pass-Through: No conditioning means no transformer hum, no capacitor noise on the output — this is actually what you want feeding an NVR on a clean facility circuit. If your grid is noisy, put a UPS upstream; don't expect the PDU to fix it.
  • External Ground Pin: A real difference-maker on serial connections (access control, camera firmware updates over RS-485). Proper site ground eliminates the majority of intermittent protocol faults I've seen in surveillance closets. The PDU15B6F12R includes this by default.

Deployment Considerations:

  • The PDU15B6F12R is passive — size your upstream circuit protection and UPS carefully. If you overload it beyond 12A sustained, the breaker trips and you lose all outlets at once. Redundancy requires two PDUs on two separate branch circuits.
  • Metal housing and cord retention are field-proven, but the tray is tight — if you're retrofitting into a crowded rack with existing cables, you'll need 20 minutes to untangle and re-route. Plan for that in your site visit.

This PDU is the right call for fixed surveillance infrastructure where you control the upstream power quality and want simplicity over conditioning. Pair it with a UPS on each PDU for redundancy, and you've got a rock-solid backbone for distributed NVR and access control systems in multi-site deployments.

Specifications
Mount Type: Wall; Rack
Product Type: Power Distribution Unit
Cable Category: Basic PDU
Form Factor: 1U Rackmount
Color: Black
Dimensions: 17.5 x 1.75 x 2.25 inches (W x H x D)
Weight: 3.7 lb
Input Voltage: 100 – 125 VAC
Output Voltage: 100 – 125 VAC
Mounting: 1U Rackmount, 0U Vertical, Under-Counter, Wall Mount
Material: Metal
Operating Temp: 32 – 95 °F (0 – 35 °C)
Standards: UL62368, UL60950-1, RoHS
Warranty: Limited Lifetime
Cord Length: 15 ft
Q&A
Reviews
Have Questions?

CyberPower 5-15R (6 Front/12 Rear) 19" 1U RM or 0U VM

$233.00
$134.99

RELATED PRODUCTS

Save $0.01
CyberPower PDU15M2F12R ,, 5-15R (2 Front/ 12 Rear) 19" 1U RM or 0U VM 5-15P
Add to Cart The item has been added

CyberPower PDU15M2F12R

CyberPower PDU15M2F12R ,, 5-15R (2 Front/ 12 Rear) 19" 1U RM or 0U VM 5-15P

14-outlet metered Power Distribution Unit designed for network-grade power distribution in rackmount, undercounter, or wall-mount configurations

    In stock · Ships same business day Free shipping over $499
    $253.00 $252.99 Save $0.01
    The item has been added Add to quote
    $253.00 $252.99 Save $0.01
    Save $0.01 Add to cart Add to quote

    System Design, Deployment & Technical Support

    Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

    Fixed scope • Fixed price

    System Design Assistance

    • Get help validating product compatibility
    • Coverage requirements
    • Storage planning and deployment architecture before you buy.
    Request Design Help

    Deployment & Configuration Support

    • Access fixed-scope support for rollout planning
    • User setup guidance
    • Migration and system standardization across single-site or multi-site deployments
    View Support Services

    Guides, Tools & Calculators

    • PoE requirements
    • Storage retention
    • Camera selection and deployment methodology
    Open Technical Resources