Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: PCD-4-8-38DC
UPC: 656747114700
Condition: New
Write a Review 46% OFF

Middle Atlantic 4in. in. WX8in. in. DX38RUDUAL DUCT - PCD-4-8-38DC

Middle Atlantic PCD-4-8-38DC Dual-Channel Vertical Cable Management DuctOverviewThe Middle Atlantic PCD-4-8-38DC is a 38RU dual-channel vertical cable…

$421.00 $226.99 SAVE $194
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Middle Atlantic 4in. in. WX8in. in. DX38RUDUAL DUCT - PCD-4-8-38DC

$421.00
$226.99

Overview

SKU: PCD-4-8-38DC
UPC: 656747114700
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Middle Atlantic PCD-4-8-38DC Dual-Channel Vertical Cable Management Duct

Overview

The Middle Atlantic PCD-4-8-38DC is a 38RU dual-channel vertical cable management duct designed for open-frame rack environments where structured cable routing is the difference between a serviceable installation and a wiring nightmare. At 4" wide, 8.06" deep, and 68" tall, it runs the full height of a standard 38RU open-frame rack — giving you dedicated vertical pathways that keep power and data separated without resorting to improvised solutions like zip-tied bundles hanging off the rear rails.

Built from black plastic and compatible with both 2-post and 4-post open-frame rack configurations, the PCD-4-8-38DC (often searched as PCD 4 8 38DC) slots into the Middle Atlantic open-frame rack ecosystem as a first-party cable management component — meaning it's dimensioned and mounted to integrate cleanly rather than adapted from a generic third-party part. If you're deploying a Middle Atlantic rack system, this is the duct that was engineered alongside it.

Key Features

  • 38RU Full-Height Coverage: At 68" tall, this duct spans the entire usable height of a 38RU open-frame rack. That means one continuous vertical pathway from top to bottom — no splicing, no mid-run transitions, no gaps where cables escape the channel and snag during maintenance.
  • Dual-Channel Configuration: Two independent channels let you physically separate cable types — for example, AC power drops on one side and structured data/low-voltage on the other. In AV or security control rooms where EMI sensitivity is a real concern, that physical separation is a practical first line of defense against noise coupling, without adding any active components.
  • 4" Width Fits High-Density Runs: The 4" channel width accommodates a realistic volume of cables for a fully-populated 38RU rack. Narrower ducts (1.5"–2") restrict how much you can route before you're forcing cables and risking jacket damage on patch-heavy rack cable management deployments.
  • 8.06" Depth — Rear-Rail Clearance for Deep Equipment: At just over 8 inches deep, the duct provides enough standoff for cables to lie naturally behind equipment with deep rear connectors (1U servers, NVRs, PoE switches) without binding. This is particularly relevant on 4-post racks where rear rail-to-rail depth determines whether your cable management actually clears the equipment.
  • 2-Post and 4-Post Compatibility: Mounts on both 2-post relay racks and 4-post open-frame cabinets. That flexibility matters in mixed environments — telecom closets typically run 2-post, while AV and security head-end rooms increasingly use 4-post open-frame for airflow. One SKU covers both without hardware substitutions.
  • Plastic Construction — Lightweight, Non-Conductive: The all-plastic build keeps the duct light (relevant when you're lifting it into a top-mount position on a tall rack) and inherently non-conductive — no grounding concerns, no galvanic corrosion issues in mixed-metal rack environments.
  • Black Finish for Professional Presentation: Black matches standard rack equipment and open-frame rack finishes. In client-visible machine rooms or broadcast environments where rack appearance matters, this is a minor but real consideration compared to mismatched silver or gray accessories.

Integration & Compatibility

The PCD-4-8-38DC is designed for open-frame rack installations — it does not mount inside enclosed rack cabinets where side-panel cable management is the norm. Verify your rack's EIA rail spacing and available side clearance before ordering: the 4" channel width requires adequate side clearance beyond the equipment's front or rear rails. This duct pairs naturally with Middle Atlantic's horizontal cable management panels and patch panels within the same rack system, giving you a complete vertical-plus-horizontal cable management architecture from a single vendor.

For security and AV integrators building out head-end rooms, the PCD-4-8-38DC works alongside PoE network switches and NVR/DVR equipment, providing the vertical routing infrastructure that keeps a dense rack organized long-term. Pair it with horizontal cable managers at every 1–2RU intervals for full containment across the rack face.

Frequently Asked Questions

Q: What rack form factor does the PCD-4-8-38DC fit?

A: The PCD-4-8-38DC is designed for 2-post or 4-post open-frame racks. It is not intended for enclosed rack cabinets where side-panel or internal cable management is used instead.

Q: How tall is the PCD-4-8-38DC, and does it span a full 38RU rack?

A: Yes — the duct measures 68" in height, which covers the full usable height of a standard 38RU open-frame rack, providing uninterrupted vertical cable routing from top to bottom.

Q: What is the dual-channel configuration used for?

A: The two independent channels allow you to physically separate different cable types — for example, running power cables in one channel and data or low-voltage cables in the other. This separation helps manage cable organization and reduces the risk of signal interference in sensitive AV or security installations.

Q: What are the exact dimensions of the PCD-4-8-38DC?

A: The duct measures 4" wide x 8.06" deep x 68" tall (height corresponds to 38RU rack coverage).

Q: What material is the PCD-4-8-38DC made from?

A: It is constructed from black plastic, which keeps the duct lightweight and non-conductive — no grounding complications in mixed-metal rack environments.

Q: Can the PCD-4-8-38DC be used on a 4-post rack as well as a 2-post relay rack?

A: Yes. The PCD-4-8-38DC is compatible with both 2-post and 4-post open-frame rack configurations, making it suitable for telecom closets (typically 2-post) and AV/security head-end rooms using 4-post open-frame racks.

Jerry Tildsen
Jerry Tildsen

The PCD-4-8-38DC is one of those parts that gets overlooked in the BOM until you're standing in front of a fully-populated 38RU open-frame rack with 80 cables dangling. The dual-channel design — two physically separate 4"-wide pathways running the full 68" height — is the practical detail that matters here: it gives you a hard separation between cable types without adding labor or hardware beyond the duct itself.

Technical Highlights:

  • Full 38RU Height (68"): One continuous run from top rail to bottom — no mid-rack transitions or gap sections that force cables out of containment during future adds/moves.
  • Dual Channel: Physical separation of cable types (power vs. data, or fiber vs. copper) in a single 4"-wide footprint. Relevant in security head-end rooms where camera feeds, door controller wiring, and AC power all converge in the same rack.
  • 2-Post and 4-Post Compatibility: The same duct installs on a relay rack in a telecom closet or a 4-post open-frame in a control room — useful when your project spec isn't finalized or the end-user changes rack type between design and install.

Deployment Considerations:

  • Confirm available side clearance on your specific rack before ordering — the 4" channel width plus the 8.06" depth needs clear space outside the EIA rail footprint; tight wall-adjacent rack positions may interfere.
  • This duct is rated for open-frame only — if the project later converts to an enclosed cabinet, the PCD-4-8-38DC does not transfer; you'd need a side-panel or internal vertical manager instead.

Best fit for security and AV integrators building dense 38RU open-frame head-end rooms where camera feeds, access control wiring, and network infrastructure all terminate in the same rack — the dual-channel vertical run keeps that mix organized and serviceable years after commissioning.

Specifications
Mount Type: Rack
Product Type: Vertical Cable Management Duct
Cable Category: Cable Management
Dimensions: 4"W x 8"D x 68"H
Material: Plastic
Mounting: 2-post or 4-post open frame rack
Width: 4"
Depth: 8.06"
Height: 68"
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources