Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: MP2-220N
UPC: 835514004745
Condition: New
Write a Review 32% OFF

Vertiv 3U Micropod Bypass for Liebert 208V UPS - MP2-220N

Vertiv MP2-220N 3U MicroPOD Maintenance Bypass for Liebert 208V UPSOverviewThe Vertiv MP2-220N is a 3U MicroPOD maintenance bypass module designed for…

$660.00 $449.99 SAVE $210
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Vertiv 3U Micropod Bypass for Liebert 208V UPS - MP2-220N

$660.00
$449.99

Overview

SKU: MP2-220N
UPC: 835514004745
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv MP2-220N 3U MicroPOD Maintenance Bypass for Liebert 208V UPS

Overview

The Vertiv MP2-220N is a 3U MicroPOD maintenance bypass module designed for Liebert GXT5 208V UPS deployments where servicing the UPS without dropping critical loads is a hard requirement. With a NEMA L6-20P utility input and four downstream 208V outlets — (2) NEMA L6-15R and (2) NEMA L6-20R — the MP2-220N (often searched as MP2 220N) bridges utility power directly to connected equipment during UPS maintenance windows, eliminating forced downtime. If you're running a Liebert GXT5 on a 208V circuit and need to swap batteries, update firmware, or perform physical service without cutting power to rack loads, this is the bypass hardware that makes that possible.

Key Features

  • NEMA L6-20P Utility Input: Designed specifically for 208V, 20A circuits — the standard feed for medium-density rack UPS deployments. Plugs directly into your facility's 208V distribution without rewiring.
  • Dual Output Mix — L6-15R and L6-20R: Four total 208V outlets ((2) NEMA L6-15R, (2) NEMA L6-20R) give you flexibility to stay connected to both 15A and 20A 208V loads simultaneously during bypass. No adapters, no load shedding required.
  • 3U Rack Form Factor: Occupies 3U of rack space in a standard 19-inch cabinet, pairing cleanly with Liebert GXT5 rack-mount UPS units and keeping bypass hardware co-located with the UPS in the same enclosure.
  • Maintenance Bypass Architecture: Routes utility power around the UPS inverter/charger entirely, so field technicians can service or replace the UPS without interrupting downstream equipment — critical in healthcare, telecom, and always-on IT environments where even scheduled downtime carries real cost.
  • Wall and Rack Mounting Support: Compatible with both rack-mount and wall-mount installation configurations, giving installers flexibility in constrained or non-standard equipment rooms.

Integration and Compatibility

The MP2-220N is designed for use within the Vertiv Liebert GXT5 UPS ecosystem. The GXT5 family supports a broad set of accessories including external battery cabinets (GXT5-EBC series), rack mounting kits (2POSTRMKIT, RMKIT18-32, 2UTELECOMRKIT), environmental sensors (SN-T, SN-TH, SN-2D, SN-3C, SN-L20), and remote monitoring via the IS-RELAY contact closure module. For larger 208V three-phase bypass requirements, Vertiv also offers the power and UPS category with higher-capacity MicroPOD variants. The MP2-220N sits specifically in the 208V single-phase segment alongside the TDU-3500RTL620 step-down distribution unit, which handles downstream 120V loads from the same L6-20P source.

If your load mix includes 120V equipment on the same UPS, review the TDU-3500RTL620 as a companion unit — it provides L5-20R and 5-15/20R outlets from the same 208V input. For pure 208V loads, the MP2-220N handles the bypass path without any voltage conversion.

Frequently Asked Questions

Q: What UPS models is the MP2-220N compatible with?

A: The MP2-220N is designed for use with Liebert GXT5 208V UPS units that use a NEMA L6-20P input connection. Verify your GXT5 model's input plug and voltage before ordering — GXT5 variants span 120V and 208V configurations, and bypass modules are voltage and connector specific.

Q: What outlets does the MP2-220N provide during bypass?

A: The MP2-220N provides four 208V outlets: (2) NEMA L6-15R and (2) NEMA L6-20R. These carry utility power directly to connected loads when the bypass is engaged, supporting both 15A and 20A 208V devices.

Q: Can the MP2-220N be wall-mounted instead of rack-mounted?

A: Yes. The MP2-220N supports both rack-mount and wall-mount installation. Optional wall-mount brackets (WMBKT2U for black finish, WMBKT2USS for stainless steel) are available separately for non-rack deployments.

Q: Does the MP2-220N support remote monitoring?

A: Remote monitoring of alarm conditions is supported via the IS-RELAY accessory, which provides contact closure output compatible with building management systems and remote monitoring platforms. The IS-RELAY is a separate purchase.

Q: Is the MP2-220N suitable for three-phase or higher-capacity 208V bypass applications?

A: No. The MP2-220N is a single-phase 208V bypass rated for NEMA L6-20P (20A) input. For higher-capacity or three-phase bypass requirements, consult the broader Vertiv MicroPOD lineup for appropriate alternatives.

Marty Allison
Marty Allison

The MP2-220N is the specific bypass module you reach for when you have a Liebert GXT5 on a 208V L6-20P circuit and can't afford a full shutdown to service the UPS. The outlet mix — (2) L6-15R and (2) L6-20R — matters in practice: most 208V rack deployments run a mix of PDU branches and direct-connected servers, and having both 15A and 20A 208V receptacles on the bypass path means you're not scrambling for adapters during a maintenance window.

Technical Highlights:

  • NEMA L6-20P Input: Hard-matched to 208V/20A single-phase distribution — no step-down or rewiring needed if your panel already feeds L6-20 circuits to your UPS row.
  • Four 208V Bypass Outlets: (2) L6-15R + (2) L6-20R provides enough coverage for the typical GXT5 load complement without stranding 15A-only devices during the bypass window.
  • 3U Rack Integration: The 3U chassis fits flush in a standard 19-inch cabinet alongside the GXT5, keeping bypass hardware co-located — no remote distribution panel required for a clean maintenance path.

Deployment Considerations:

  • Confirm your GXT5 variant uses the L6-20P input connector before ordering — Vertiv's GXT5 family spans both 120V and 208V input configurations, and the wrong bypass module won't mate physically or electrically.
  • Remote monitoring via contact closure requires the separate IS-RELAY accessory — the MP2-220N itself has no built-in network interface or SNMP capability.

This unit fits cleanly in edge data rooms, telecom closets, and healthcare IT equipment spaces running 208V single-phase infrastructure where the GXT5 is the primary UPS and zero-downtime maintenance is a site requirement.

Specifications
Mount Type: Wall; Rack
Is-Relay: Provides contact closure for remote monitoring of alarm conditions in your GXT5 UPS.
2Utelecomrkit: Center mount only 2 post rack mounting kit for 19" wide telecom/relay racks
2Postrmkit: Front flush or center mount 2 post rack mounting kit; 4 piece design
Wmbkt2U: Wall-mount bracket for 2U UPS, black
Wmbkt2Uss: Wall-mount bracket for 2U UPS, stainless steel
Sn-T: Sensor Single Modular Temperature Probe
Sn-Th: Modular Sensor
Sn-2D: Two-Door Switch Monitor Sensor Probe With Two Inputs
Sn-3C: Three Dry Contact Input Monitor Sensor
Pepgxt-1Klf: Power Emergency Service with LIFE™
4Utelecomrkit: Center mount only 2 post rack mounting kit for 19" wide telecom/relay racks
2 X Gxt5-Ebc288Vrt4U: External Battery Cabinet
2 X Gxt5-288Vbatkit: Replacement Battery Kit
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources