Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The CyberPower PDU83106 is a 3-phase switched, metered-by-outlet (MBO) PDU designed for high-density rack deployments running 200–240V three-phase power at up to 30A. With 24 IEC C13 and 6 IEC C19 outlets — 30 total — it covers a fully loaded rack of mixed 1U servers, storage nodes, and high-draw GPU appliances without requiring a separate PDU per power zone. If you're building out a dense compute or network video recorder rack where per-outlet switching and real-time load visibility matter, the PDU83106 is engineered for exactly that environment.
The 0U form factor means it mounts vertically in the rear of a standard rack, keeping all 42U of usable rack space available for equipment — a meaningful constraint in co-located or edge data center deployments where rack space is priced by the U.
The PDU83106 speaks SNMPv1 and SNMPv3, HTTP/HTTPS, SSH, Telnet, FTP, NTP, SMTP, DNS, DHCP, TCP/IP, SSL, TLS, LDAP(S), RADIUS, Syslog, CLI, UDP, and Windows AD — essentially the full stack of enterprise management protocols. This makes it compatible with any managed network infrastructure running standard NMS or DCIM tooling. The dual-stack IPv4/IPv6 management interface removes addressing constraints in modern data center environments.
For physical compatibility, verify your facility's three-phase distribution panel includes a 30A IEC 60309 circuit. This PDU does not accept standard NEMA L6-30 or L21-30 inputs — the IEC 60309 input is an industrial connector standard common in European-style data center buildouts and purpose-built colocation facilities. If your existing whips terminate in a different connector, factor in a pigtail adapter or rewire before ordering.
Q: What input connector does the PDU83106 use, and is it compatible with standard North American data center whips?
A: The PDU83106 uses an IEC 60309 industrial input connector rated for 30A at 200–240V three-phase. This is common in European-standard and purpose-built colocation facilities. Many North American data centers use NEMA L21-30 or L6-30 whips — verify your facility's distribution before ordering, as an adapter or custom whip may be needed.
Q: Can I control individual outlets remotely on the PDU83106?
A: Yes. The PDU83106 is a Switched MBO (Metered by Outlet) unit, meaning each of the 30 outlets can be individually powered on, off, or sequenced via the network management interface. This enables remote server reboots and load management without a physical site visit.
Q: Does the PDU83106 support SNMP monitoring integration with third-party NMS platforms?
A: Yes. The PDU83106 supports both SNMPv1 and SNMPv3 (with encryption), making it compatible with standard network management platforms such as SolarWinds, PRTG, and Nagios for outlet-level telemetry and alerting.
Q: How many network ports does the PDU83106 have, and can PDUs be daisy-chained?
A: The PDU83106 includes two RJ-45 Ethernet ports, which support daisy-chaining multiple PDUs together for consolidated management — reducing the number of switch ports required per PDU row.
Q: Can firmware on the PDU83106 be updated in an air-gapped environment?
A: Yes. The PDU83106 includes a USB port specifically for firmware upgrades, allowing updates without requiring network access — suitable for high-security or air-gapped deployments.
Q: What monitoring parameters does the PDU83106 display on its LCD?
A: The front-panel LCD displays real-time current and voltage readings, providing on-site visibility into load levels without requiring a network connection or separate metering equipment.

The PDU83106 is one of the more complete options I've seen at this outlet count and phase configuration — 30 individually switched outlets at 30A/208V three-phase, with dual RJ-45 for daisy-chaining, SNMPv3, LDAP, RADIUS, and a front LCD that gives you load data without opening a browser. For high-density rack builds, that combination of per-outlet control and enterprise protocol depth is what separates a manageable infrastructure from one that requires physical intervention every time a server locks up.
Technical Highlights:
Deployment Considerations:
The PDU83106 is the right spec for a purpose-built colocation row or on-premises data center where three-phase 208V distribution is already in place, the team needs remote outlet control across a dense rack, and enterprise directory integration is a hard requirement from the security team — not a nice-to-have.