Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv ZCL03U 3.5kW Low Ambient Outdoor Condenser Unit

Overview

The Vertiv ZCL03U is a 3.5kW outdoor condenser unit engineered for SmartCabinet deployments in harsh, low-ambient environments where standard indoor cooling simply won't survive. Rated for outdoor installation and built to handle industrial conditions, the ZCL03U pairs with Vertiv SmartCabinet enclosures to deliver active thermal management to edge infrastructure that must run reliably outside a data center envelope — think remote IDF closets in manufacturing, roadside telecom cabinets, utility yards, and outdoor surveillance command nodes. At 149.91 lbs and 45.8 inches wide, this is a serious piece of thermal infrastructure, not a plug-and-play accessory.

For integrators working on outdoor cooling units and edge thermal management, or engineers sourcing from the broader Vertiv infrastructure catalog, this condenser is the field-side component that makes sealed outdoor cabinet deployments viable in climates with wide temperature swings.

Key Features

  • 3.5kW Cooling Capacity: Sized to handle the heat load of a densely populated SmartCabinet — enough headroom for active edge compute, PoE switching stacks, or compact NVR/server configurations running 24/7. Under-specifying cooling capacity in outdoor cabinets is one of the most common causes of premature hardware failure; 3.5kW gives you real margin.
  • Low Ambient Design: Conventional condensers stall or cycle erratically when outdoor ambient temperatures drop near or below freezing. The ZCL03U's low-ambient engineering addresses this directly, maintaining stable operation in cold-weather climates without requiring aftermarket workarounds or heater kits.
  • Outdoor-Rated Construction: Built for harsh and industrial environments — this unit is meant to be mounted outside, exposed to weather, dust, and temperature extremes. That design mandate shapes the enclosure sealing, component selection, and airflow path in ways that indoor-rated units simply don't account for.
  • Zero-U Form Factor: The ZCL03U integrates with the SmartCabinet system without consuming rack unit space inside the enclosure. For edge deployments where every U counts — especially in 12U or smaller outdoor cabinets — keeping the condenser external to the usable rack space is a meaningful operational advantage.
  • UL Listed: UL certification matters on jobs that require it — particularly utility, municipal, and government infrastructure where the authority having jurisdiction (AHJ) will inspect. Specifying a UL-listed condenser removes a common submittal obstacle.
  • Dimensional Footprint (45.8" W × 11.1" D × 20.7" H): Know this before you plan the cabinet pad or wall mount. At nearly four feet wide, site layout needs to account for clearance on both sides for airflow. The 11.1-inch depth keeps the profile manageable against a wall or fence line.
  • 149.91 lb Operational Weight: Structural planning is non-negotiable. Whether this is wall-mounted, pad-mounted, or integrated into a cabinet frame, your mounting surface needs to be engineered for the load — plus dynamic wind and seismic factors depending on jurisdiction.

Integration & Compatibility

The ZCL03U is designed as a field-side condenser for Vertiv SmartCabinet systems. It does not function as a standalone air conditioning unit — it works in conjunction with the SmartCabinet's internal evaporator and control system. Confirm SmartCabinet model compatibility before ordering; Vertiv publishes system pairing documentation that maps condenser SKUs to specific cabinet configurations.

Installations in outdoor edge infrastructure deployments — remote switching nodes, outdoor surveillance aggregation points, utility SCADA enclosures — are the primary use case. If your project involves an indoor cabinet or a climate-controlled room, this condenser is not the right product; that scenario calls for a precision air unit or in-row cooler.

Electrical integration requires coordination with the site's power design. Verify input voltage, phase, and amperage requirements against the specific SmartCabinet system documentation before commissioning. The 3-year limited manufacturer warranty applies to the ZCL03U as a system component.

Frequently Asked Questions

Q: What is the cooling capacity of the ZCL03U?

A: The ZCL03U delivers 3.5kW of cooling capacity, designed for outdoor SmartCabinet deployments handling dense edge compute and networking loads running continuously.

Q: Is the ZCL03U designed for standalone use or does it require a SmartCabinet?

A: The ZCL03U is a condenser unit engineered to work as part of Vertiv's SmartCabinet system. It is not a standalone air conditioning unit — it pairs with the SmartCabinet's internal evaporator and controls. Confirm cabinet compatibility with Vertiv's pairing documentation before ordering.

Q: What is the warranty on the ZCL03U?

A: The ZCL03U carries a 3-year limited manufacturer warranty.

Q: Can the ZCL03U operate in cold climates?

A: Yes. The ZCL03U is specifically engineered as a low-ambient design, which means it is built to maintain stable operation when outdoor temperatures drop near or below freezing — a known failure mode for standard condensers not rated for low-ambient conditions.

Q: Is the ZCL03U UL listed?

A: Yes, the ZCL03U is UL listed, which satisfies AHJ inspection requirements on utility, municipal, and government infrastructure projects that mandate UL certification for outdoor electrical equipment.

Q: What are the physical dimensions and weight of the ZCL03U?

A: The unit measures 45.8 inches wide × 11.1 inches deep × 20.7 inches tall and weighs 149.91 lbs operationally (210 lbs shipping weight). Structural mounting must be engineered to support this load, accounting for wind and seismic factors per local code.

Ted Perry
Ted Perry

The ZCL03U is one of those units that only makes sense once you've tried to keep edge gear alive in an uncontrolled outdoor enclosure through a midwest winter or a Gulf Coast summer. The low-ambient condenser design is the engineering detail that separates a cabinet that makes it through February from one that goes into thermal protection mode at 3am during a hard freeze. At 3.5kW, this unit has the capacity to handle a real load — not just a switch and a media converter, but an NVR stack, PoE aggregation, and processing compute running continuously in a sealed SmartCabinet.

Technical Highlights:

  • 3.5kW Capacity: Sufficient for high-density edge cabinet loads — equivalent to managing the heat output of roughly 12–15 PoE+ ports fully loaded plus a compact server, with margin to spare before the system goes into thermal alarm.
  • Low-Ambient Engineering: Standard split condensers lose efficiency and cycling stability below about 15°C ambient. The ZCL03U's low-ambient design maintains operation well below that threshold — critical for deployments in northern climates or high-altitude sites where winter ambient frequently drops below freezing.
  • UL Listing: On public sector and utility jobs, a UL-listed condenser is often a hard submittal requirement. Having it on the ZCL03U removes a scope-of-work negotiation that would otherwise require a variance or a substitution approval from the AHJ.

Deployment Considerations:

  • At 149.91 lbs operational and 210 lbs shipping, rigging and structural mounting require planning before the unit ships. Do not assume a standard wall mount bracket will handle this load — get a structural assessment if you're mounting to an existing wall rather than a concrete pad.
  • The ZCL03U is 45.8 inches wide. In tight site layouts — fence lines, narrow equipment yards, building parapets — confirm you have adequate lateral clearance for condenser airflow before finalizing the cabinet placement. Restricted airflow will suppress capacity and accelerate wear on the compressor.

This condenser is the right call for outdoor SmartCabinet deployments at hardened perimeter security nodes, remote utility SCADA enclosures, or transportation infrastructure sites where the cabinet must survive full weather exposure year-round with no HVAC in the surrounding structure. If your site is indoors or climate-controlled, the ZCL03U is overkill — redirect that budget to precision in-row cooling instead.

Specifications
Brand: Vertiv
Model: ZCL03U
Product Type: Airflow System Condenser
Cooling Capacity: 3.5 kW
Design: Low Ambient, Outdoor Installation
Rack Compatibility: Zero-U Form Factor
Height: 20.7 in
Width: 45.8 in
Depth: 11.1 in
Weight: 149.91 lbs
Environment: Harsh/Industrial, Outdoor Rated
Warranty: 3-Year Limited
Shipping Weight: 210 lbs.
freight: 565.40
Q&A
Reviews

Vertiv 3.5KW LA OUTDR COOLNG UNIT UL - ZCL03U

$6,725.00
$4,782.99

RELATED PRODUCTS

Save $2,354.01
Vertiv GXT5-5KL630RT3UXLN UPS UL
Add to Cart The item has been added

Vertiv GXT5-5KL630RT3UXLN

Vertiv GXT5-5KL630RT3UXLN UPS UL

4,900 VA / 4,600 W online double-conversion UPS built for rack or tower deployment in demanding environments where power quality is non-negotiable

    In stock · Ships same business day Free shipping over $499
    $8,036.00 $5,681.99 Save $2,354.01
    The item has been added Add to quote
    $8,036.00 $5,681.99 Save $2,354.01
    Save $2,354.01 Add to cart Add to quote

    System Design, Deployment & Technical Support

    Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

    Fixed scope • Fixed price

    System Design Assistance

    • Get help validating product compatibility
    • Coverage requirements
    • Storage planning and deployment architecture before you buy.
    Request Design Help

    Deployment & Configuration Support

    • Access fixed-scope support for rollout planning
    • User setup guidance
    • Migration and system standardization across single-site or multi-site deployments
    View Support Services

    Guides, Tools & Calculators

    • PoE requirements
    • Storage retention
    • Camera selection and deployment methodology
    Open Technical Resources