Vertiv 2XPRC060-103L20TL5 BASIC - 12577
Rack-mountable power distribution unit (PDU) designed to provide reliable power to IT equipment within a data center or network closet
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv 2XPRA060-103L20TL5 (part number 13213) is a 2U horizontal metered rack power distribution unit rated at 30A, 120V, delivering up to 2.8kW to six NEMA L5-20R receptacles in a standard 19-inch rackmount chassis. If you've ever had a technician accidentally overload a circuit while hot-swapping servers into a densely packed rack, this is the unit that prevents that — a front-facing local LED display gives you real-time RMS current data without logging into anything. Built and tested in the USA, it carries TAA compliance and Buy American Act COTS status, which matters for federal IT and government-adjacent deployments where sourcing origin is a procurement gate, not an afterthought.
This unit is part of the Vertiv PowerIT rPDU line, a family of rack power distribution units covering basic, metered, monitored, and switched configurations. For teams deploying rack PDUs across mixed-voltage data center environments, the 13213 fills the straightforward 30A single-phase metered slot without added network overhead.
The 13213 is a metered-standard unit with no network interface — there is no IP address to assign, no firmware to update, and no SNMP or Modbus integration. If your deployment requires per-outlet switching, remote monitoring, or environmental sensing, you'll need to step up within the Vertiv PowerIT monitored or switched rPDU families. This unit is the right choice when your monitoring strategy is handled upstream (at the UPS or branch circuit metering panel) and you need local visibility for hands-on technicians without adding management overhead to the PDU layer.
The L5-20R receptacles accept NEMA L5-20P plugs, which are standard on most 120V server and networking gear. Confirm your equipment's actual plug type before ordering — L5-20R will not accept L6-20P (250V locking) or standard NEMA 5-15P/5-20P straight-blade plugs without an adapter. For planning data center power infrastructure, pair this PDU with a UPS capable of sourcing a 30A L5-30R output to the PDU input.
Operating temperature range of 10-45°C (50-113°F) covers typical conditioned data center and comms room environments. It is not rated for uncontrolled ambient above 45°C — plan accordingly for edge or industrial deployments without active cooling.
Q: Is the Vertiv 13213 TAA compliant?
A: Yes. The 2XPRA060-103L20TL5 is manufactured in the USA and is documented as TAA Compliant and Buy American Act COTS Compliant, making it eligible for federal and SLED procurement under those requirements.
Q: What is the warranty on the 13213?
A: Vertiv covers the 2XPRA060-103L20TL5 with a 5-year limited warranty.
Q: Does the 13213 have network monitoring or SNMP capability?
A: No. The 13213 is a metered-standard rPDU with local LED current monitoring only. It has no network interface, no IP address, and no remote monitoring capability. If you need SNMP, Modbus, or per-outlet switching, you would need a monitored or switched variant from the Vertiv PowerIT rPDU family.
Q: What plug does the 13213 require at the input, and what receptacles does it provide?
A: The input uses a NEMA L5-30P twistlock plug (included on the 10-foot cord), requiring an L5-30R outlet on your upstream panel or UPS. The six output receptacles are NEMA L5-20R, rated at 120V / 20A each.
Q: How are the six outlets distributed across the circuit breakers?
A: The 13213 has two independent 20A single-pole magnetic breakers, each protecting three of the six rear receptacles. A fault or manual trip on one breaker drops three outlets, leaving the other three active.
Q: What are the chassis dimensions and weight of the 13213?
A: The chassis measures 3.39 inches (H) x 17 inches (W) x 6 inches (D) and ships at 15 lbs (6.8 kg). It mounts in a standard 2U 19-inch horizontal rackmount bay and supports 19-inch recessed mounting.

The Vertiv 13213 earns its place in deployments where local current visibility matters more than remote telemetry — specifically because its digital RMS meter holds +/-2% accuracy, which is accurate enough to use as a real capacity-planning tool, not just a ballpark indicator. I reach for this unit when the rack environment has a hands-on ops team that doesn't want to manage another networked device just to know whether they're at 60% or 85% of their 30A circuit.
Technical Highlights:
Deployment Considerations:
This is the right unit for a federal or SLED colocation deployment where the PDU layer needs to be simple, compliant, and maintainable by a rotating ops team — no credentials to rotate, no firmware to patch, no network segment to protect. The local display does its job every time someone opens the cabinet door.