Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: VRA2013
UPC: 767041035551
Condition: New
Write a Review 31% OFF

Vertiv 2U 19 Black Plastic Tool Less Airflow Blanking Panel (qty. 10) - VRA2013

Vertiv VRA2013 2U 19-Inch Tool-Less Airflow Blanking Panel, 10-PackOverviewThe Vertiv VRA2013 is a 2U, 19-inch black plastic blanking panel sold in pa…

$264.00 $181.99 SAVE $82
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Vertiv 2U 19 Black Plastic Tool Less Airflow Blanking Panel (qty. 10) - VRA2013

$264.00
$181.99

Overview

SKU: VRA2013
UPC: 767041035551
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv VRA2013 2U 19-Inch Tool-Less Airflow Blanking Panel, 10-Pack

Overview

The Vertiv VRA2013 is a 2U, 19-inch black plastic blanking panel sold in packs of 10 — the correct answer when you have empty rack slots bleeding conditioned air into the hot aisle before it ever reaches the equipment that needs it. Unsealed rack units are among the most common and most overlooked causes of thermal runaway in dense equipment rooms and edge deployments. These panels snap in without tools, which matters on a rack refresh or post-install audit where you are filling a dozen slots across multiple enclosures and do not want to chase a screwdriver through a live cabinet.

Designed specifically for Vertiv open-frame rack enclosures, the VRA2013 pairs directly with the VR-series lineup and eliminates the guesswork on fitment. If you are populating a new rack or backfilling empty U-space after decommissioning gear, these panels belong in the order alongside the rack itself.

Key Features

  • Tool-Less Snap-In Installation: No fasteners, no screwdriver — the panel clips directly into standard 19-inch rack rails. On a multi-rack deployment where you need to seat 20 or 30 blanks across an afternoon, this is not a minor convenience; it is a real labor reduction.
  • 2U Height per Panel: Each panel covers two rack units of open space. Filling a 4U gap takes two panels instead of four — fewer parts to track, faster install compared to a 1U-only solution. The VRA2013 and its 1U sibling (VRA2000) can be mixed to match any open-slot configuration.
  • Black Plastic Construction: Lightweight and electrically non-conductive — appropriate for blanking panels that do not carry any load. The plastic construction keeps per-panel weight down, which matters for the overall rack weight budget in raised-floor environments with strict floor-load ratings.
  • 19-Inch (48.3 cm) Standard Form Factor: Fits any EIA-standard 19-inch rack, not just Vertiv enclosures. This means if you are managing a mixed-vendor rack environment, these panels are not proprietary dead-ends — they install wherever a standard 19-inch rail set exists.
  • Airflow Bypass Elimination: Open rack slots allow cold supply air to short-circuit directly to the return plenum or hot aisle without contacting any equipment. Even a single unsealed 2U gap can measurably raise inlet temperatures on adjacent servers. Sealing those gaps forces conditioned air through the equipment, not around it — the fundamental principle behind hot-aisle/cold-aisle containment.
  • 10-Panel Pack Quantity: A single VRA2013 order covers 20U of open rack space. For a 42U rack at typical fill ratios (60–70% populated), that is enough to seal the remainder of a standard cabinet in one SKU. If you are sealing a full rack farm, the VRA2014 (200-count bulk pack) is the same panel at higher volume.
  • Verified Rack Compatibility: Confirmed fitment across the Vertiv VR-series open rack enclosures including VR3100, VR3300, VR3150, VR3350, VR3105, VR3305, VR3107, VR3307, VR3157, and VR3357. If your enclosure is on that list, there is no ambiguity on whether these panels will seat correctly.

Integration & Compatibility

The VRA2013 is part of Vertiv's broader rack accessory ecosystem for the VR-series open-frame enclosures. Vertiv's blanking panel lineup covers 1U (VRA2000/VRA2001/VRA2003) and 2U (VRA2013/VRA2014) plastic tool-less options, plus a sheet metal kit (VRA2002) that covers 1U, 2U, 4U, and 8U in a single SKU if you need mixed heights from one order. For more comprehensive airflow management — cable entry brush strips, top fan kits, or vertical exhaust ducts — Vertiv offers the VRA2005 through VRA2012 accessories in the same family.

Standard 19-inch EIA rail spacing means these panels are not limited to Vertiv enclosures. Any rack with standard 19-inch mounting rails and standard U-pitch will accept them. That said, clip retention is optimized for Vertiv rail profiles, so fitment on third-party enclosures should be verified before ordering at scale.

What's in the Box

  • 10x Vertiv VRA2013 2U 19-inch black plastic tool-less airflow blanking panels

Frequently Asked Questions

Q: How many rack units does a single VRA2013 cover?

A: Each panel covers 2U. The pack of 10 covers a total of 20U of open rack space.

Q: Does the VRA2013 require tools or screws to install?

A: No. The panel is tool-less — it clips directly into standard 19-inch rack rails without fasteners or a screwdriver.

Q: Which Vertiv enclosures is the VRA2013 confirmed to fit?

A: Confirmed compatible with the Vertiv VR3100, VR3300, VR3150, VR3350, VR3105, VR3305, VR3107, VR3307, VR3157, and VR3357 open-frame rack enclosures.

Q: Is there a higher-volume version of the same panel?

A: Yes. The VRA2014 is the same 2U blanking panel in a 200-count pack — the right SKU for large deployments or stocking a rack room.

Q: Can I mix the VRA2013 with 1U blanking panels to fill odd-sized gaps?

A: Yes. The VRA2013 (2U) works alongside the VRA2000 (1U, qty 10) or VRA2003 (1U, qty 2) to cover any combination of open rack units without leaving partial gaps unsealed.

Q: Does the VRA2013 fit non-Vertiv 19-inch racks?

A: The 19-inch (48.3 cm) form factor is EIA-standard, so the panel will physically span standard rails. Clip retention is designed for Vertiv VR-series rail profiles — verify fitment on third-party enclosures before ordering in bulk.

Jerry Tildsen
Jerry Tildsen

The VRA2013 is one of those line items that disappears into a rack BOM without much thought — and that is exactly how it should work. A 2U tool-less plastic blank is not a complicated product, but the failure mode when you skip it is real: open rack slots in a hot-aisle/cold-aisle layout can raise server inlet temperatures by several degrees Celsius, enough to trigger throttling on tightly-cooled edge nodes or push a UPS room past its CRAC setpoint on a hot day.

Technical Highlights:

  • 2U Coverage per Panel: At 10 panels per pack, the VRA2013 seals 20U in a single order — enough to close out the open space in a partially populated 42U cabinet at one shot without mixing SKUs.
  • Tool-Less Clip-In Design: No fasteners means no dropped screws inside a live rack and no need to pull adjacent gear to get a blanking panel seated. In a colocation or edge-closet environment where live rack work happens regularly, that is a genuine operational advantage.
  • Verified VR-Series Fitment: Confirmed across 10 specific Vertiv VR-series enclosure SKUs (VR3100 through VR3357). If your rack is on that list, order with confidence — no fitment ambiguity, no returns.

Deployment Considerations:

  • For large rack-room buildouts — 10 or more cabinets — the VRA2014 (200-count bulk pack of the identical panel) will be significantly more cost-efficient than ordering multiple VRA2013 packs. Plan your U-space inventory before the rack delivery arrives, not after.
  • Clip retention is engineered for Vertiv VR-series rail profiles. On third-party 19-inch enclosures the panel will span the rails dimensionally, but clip engagement may be looser than intended — verify on a single unit before ordering at scale in a mixed-vendor environment.

The VRA2013 belongs in every Vertiv VR-series rack order going into a thermally managed data center, server room, or edge network closet where hot-aisle containment is in play. It is not an afterthought — it is the last step that makes the airflow management system actually function as designed.

Specifications
Type: Blank panel
Product colour: Black
Housing material: Plastic
Rack capacity: 2U
Compatibility: Vertiv VR3100 VR3300 VR3150 VR3350 VR3105 VR3305 VR3107 VR3307 VR3157 VR3357
Size (imperial: 48.3 cm (19")
Quantity per pack: 10 pc(s)
Package width: 513 mm
Package depth: 213 mm
Package height: 208 mm
Package weight: 3 kg
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

Ubiquiti UACC-RACK-PANEL-BLANK-2U Rack mount 2U blank panel - image 2
Add to Cart The item has been added

Ubiquiti

SKU: UACC-RACK-PANEL-BLANK-2U

Ubiquiti UACC-RACK-PANEL-BLANK-2U Rack mount 2U blank panel

2U blank panel for 19-inch racks, airflow and cable management

  • Fills 2U of unused rack space, blocking air bypass paths that degrade cooling.
  • Fits any standard 19-inch rack without power or cabling — purely mechanical install.
  • SPCC cold-rolled steel with gray finish blends into mixed-equipment network cabinets.
$53.99
The item has been added
Free shipping over $499
$53.99
Add to cart Add to quote

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources