Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology C1L36TA-YCME2799 208V 30A 0U Rack PDU
The Server Technology C1L36TA-YCME2799 is a 0U vertical rack power distribution unit built for data center and server room cabinets that need high outlet density without eating into usable rack space. Rated for 208V input at 30A, this unit is designed to feed a mixed load of servers, switches, and storage devices from a single locking NEMA L21-30P inlet, giving integrators a straightforward way to power a fully loaded rack without daisy-chaining multiple PDUs.
Overview
Because the C1L36TA-YCME2799 mounts in 0U orientation, it runs vertically along the rear rail of the cabinet instead of consuming horizontal rack units that would otherwise go to compute or network gear. That matters in dense colocation and enterprise server rooms where every U counts. With 36 total outlets split across two connector types, this PDU is sized for cabinets with a mix of standard IEC C14-corded equipment and higher-current locking-cord devices — a common combination in server racks that include both commodity 1U/2U servers and heavier network or storage chassis.
Key Features
- 208V / 30A input rating: matches standard three-phase-derived or split-phase 208V data center power plans, letting the PDU carry a full rack of mixed IT load without tripping a branch circuit sized for typical enterprise power density.
- 18x C13 outlets: covers the standard IEC C14 power cord found on most rack servers, switches, and small UPS units — no adapters needed for the majority of a typical rack build-out.
- 18x locking-style (CX) outlets: a second bank of 18 outlets gives you a dedicated set of connections for devices where a friction-fit C13 plug isn't reliable enough, useful in racks that see vibration, frequent service access, or a high-density blade environment where accidental unplugs are a real risk.
- 36 total outlets on one PDU: reduces the number of PDUs needed per cabinet, which simplifies cable management and cuts down on the number of upstream breaker positions you need to plan for in the power design.
- NEMA L21-30P input plug: a twist-lock connector rated for the full 30A load, reducing the chance of an inlet cord working loose under cabinet vibration or during hot-aisle maintenance work compared to a straight-blade plug.
- 0U form factor: mounts vertically in the rear of the cabinet, preserving every horizontal rack unit for servers and network equipment — a meaningful consideration in cabinets already tight on U-space.
Integration & Compatibility
Because the C1L36TA-YCME2799 terminates in a NEMA L21-30P locking plug, confirm your upstream power whip or floor PDU is provisioned with a matching L21-30 receptacle rated for 208V/30A before ordering — this is a facility-side planning step, not something the PDU itself adapts to. When you're specifying rack power alongside network video recorders or other always-on infrastructure, review a PoE and power planning guide to make sure your total connected load stays within the 30A branch rating. For racks running surveillance recording platforms, pairing this PDU with properly sized PoE network switches and NVR hardware on separate outlet banks helps isolate loads for easier troubleshooting. It's worth browsing the broader Server Technology power distribution line if this specific outlet mix or 0U footprint doesn't match your cabinet, since the family includes other outlet counts and input ratings. If your deployment calls for redundant power paths, review an rack power distribution overview before finalizing a single-PDU design, since a 0U unit like this one is typically deployed in an A/B pair for critical infrastructure.
Frequently Asked Questions
Q: What input voltage and amperage does the C1L36TA-YCME2799 support?
A: It's rated for 208V input at 30A, delivered through a NEMA L21-30P locking plug.
Q: How many outlets does the C1L36TA-YCME2799 have?
A: 36 total outlets — 18x C13 and 18x locking-style (CX) outlets.
Q: Does the C1L36TA-YCME2799 mount in a standard rack unit space?
A: No — it's a 0U unit designed to mount vertically along the rear rail of the cabinet, so it doesn't consume horizontal rack units.
Q: What kind of plug does the C1L36TA-YCME2799 require on the input side?
A: A NEMA L21-30P locking receptacle rated for 208V/30A must be available upstream to connect this PDU.
Q: Can the C1L36TA-YCME2799 power equipment with both standard and locking power cords?
A: Yes — its 18 C13 outlets accept standard IEC C14 cords, while its 18 CX outlets are intended for locking-style cord connections.

When I'm speccing rack power for a dense cabinet, the outlet mix on the C1L36TA-YCME2799 is what catches my eye first — 18 C13 plus 18 CX on a single 208V/30A feed is enough density to cover a mixed rack of standard servers and locking-cord gear without stacking two separate PDUs.
Technical Highlights:
- 208V/30A input via NEMA L21-30P: gives you headroom for a fully populated cabinet on one circuit, and the twist-lock plug is far less likely to back out during rear-of-rack cable work than a straight-blade connector.
- 36 total outlets (18x C13 / 18x CX): lets you dedicate the locking bank to gear you can't afford to have bump loose — think switches or storage controllers in a rack that gets touched often — while the C13 bank handles everyday IEC-corded servers.
- 0U vertical form factor: the whole unit rides the rear rail, so none of your 42U (or however many U your cabinet has) goes to power distribution instead of compute.
Deployment Considerations:
- Confirm the cabinet's upstream whip is terminated with a matching L21-30 receptacle before this shows up on-site — a 30A locking PDU is useless without a compatible receptacle already in place.
- With 36 outlets on one 30A branch, plan your load distribution across both outlet banks carefully; it's easy to overload one side of a dense rack build if you're not tracking amperage per outlet group as you populate the cabinet.
This is the right call for a single-cabinet data center or colo deployment where you're consolidating a mixed fleet of C13-corded servers and locking-cord network gear onto one 0U PDU instead of running two half-populated units — the C1L36TA-YCME2799 earns its keep in exactly that scenario.
Compare with similar
Server Technology 208V 30A 18XC13 18XCX NEMA - C1L36TA-YCME2799
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology