Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit OCFX5WH-X Outside Corner Fitting for Pan-Way LDPH5/LDS5 Surface Raceway

The Panduit OCFX5WH-X is a 600V-rated outside corner fitting for the Pan-Way™ LDPH5 and LDS5 surface raceway system, sold in a 10-pack. If you're routing power and data cables along perimeter walls and need a clean, code-compliant transition at outside corners, this fitting is the purpose-built solution — sized at 2.86" × 0.64" to mate precisely with LDPH5 duct profiles without shimming or field-fabrication. It ships white to match the standard Pan-Way color family.

Key Features

  • 600V Power Rating: Rated for applications up to 600V, meaning this corner fitting handles both low-voltage data runs and higher-voltage power circuits in the same raceway pass — no need to separate your power and data pathways into different duct brands at corner transitions.
  • UL5A Listed and UL94V-0 Flame Rating: UL5A listing confirms the fitting meets the surface metal raceway standard for electrical safety, while UL94V-0 means the PVC self-extinguishes — a requirement in commercial occupancies where AHJ inspectors check flame spread on raceway accessories, not just the duct itself.
  • TIA/EIA and UL Compliance: Meets TIA/EIA structured cabling standards, so specifying this fitting in a TIA-compliant data installation doesn't break your standards chain. FT4 (UL 2556 flame test) certification adds a second fire-performance verification layer.
  • Precision-Fit Dimensions (2.86" W × 0.64" H / 72.6mm × 16.3mm): These dimensions are matched to the LDPH5 profile — not generic. An off-brand corner piece at this size will gap or require tape; this one drops in and aligns flush, which matters for finished commercial spaces where gaps draw inspection comments.
  • PVC Construction: PVC strikes the right balance for indoor commercial surface raceway: it's light, paintable, and chemically inert against the cleaning products used in healthcare, retail, and office environments. It's not rated for outdoor UV exposure or wet locations — keep it to interior runs.
  • 10-Pack Quantity: Sold as a 10-pack (OCFX5WH-X), which matches the typical project buy for a perimeter wall run with multiple outside corners. Ordering by the pack avoids the per-fitting freight cost that makes single-piece orders inefficient for integrators pricing a job.
  • Pan-Way™ Sub-Brand: Pan-Way is Panduit's surface raceway product family — fittings, bases, covers, and accessories are engineered to share tolerances across the line, so an OCFX5WH-X corner sourced later won't introduce the fitment drift you sometimes see when mixing raceway generations from different manufacturers.

Integration & Compatibility

The OCFX5WH-X is designed for use with Panduit Pan-Way LDPH5 single-channel surface raceway and LDS5 duct base/cover systems. It is not interchangeable with other duct widths in the Pan-Way family — verify your installed duct profile before ordering. The 72.6mm (2.86") width matches the LDPH5 form factor specifically.

For complete cable management raceway runs, pair this outside corner with the matching inside corner, flat elbow, and end cap fittings in the LDPH5/LDS5 family to keep the entire installation within a single tolerance-matched system. For PoE camera drops and IP camera cable routing along perimeter walls, the Pan-Way system's multi-channel variant (LD2P10 profile) supports simultaneous power and data routing — confirm which base profile your project specifies before mixing fittings.

The white finish (Blanco) matches standard Pan-Way duct color. If the installation uses painted raceway, standard latex or spray paint adheres to PVC — the UL94V-0 rating is maintained after painting per Panduit's surface raceway application guidance.

Review your surface raceway systems selection for duct base, cover, and fitting compatibility before specifying this fitting on a bid sheet — the LDPH5 and LDPH10 profiles are different widths and their fittings are not cross-compatible.

What's in the Box

  • 10× Panduit OCFX5WH-X outside corner fittings (white PVC)

Frequently Asked Questions

Q: What raceway profiles is the OCFX5WH-X compatible with?

A: The OCFX5WH-X is designed for use with Panduit Pan-Way LDPH5 and LDS5 surface raceway profiles. It is not interchangeable with other duct widths such as LDPH10 — verify your installed duct profile before ordering.

Q: What voltage is the OCFX5WH-X rated for?

A: The OCFX5WH-X outside corner fitting is rated for applications up to 600V, making it suitable for both power and low-voltage data cable routing in the same raceway run.

Q: Is the OCFX5WH-X UL listed?

A: Yes. The OCFX5WH-X carries a UL5A listing and meets UL94V-0 flame requirements. It also complies with TIA/EIA structured cabling standards and FT4 flame testing.

Q: How many fittings come in the OCFX5WH-X package?

A: The OCFX5WH-X is sold as a 10-pack of outside corner fittings.

Q: Can the OCFX5WH-X be used outdoors?

A: No. The OCFX5WH-X is a PVC fitting intended for interior commercial surface raceway installations. It is not rated for outdoor UV exposure or wet locations.

Q: What are the exact dimensions of the OCFX5WH-X?

A: The OCFX5WH-X measures 2.86 inches (72.6mm) wide by 0.64 inches (16.3mm) tall — matched to the LDPH5 duct profile dimensions.

James Everett
James Everett

The OCFX5WH-X is one of those fittings that looks trivial on a BOM until you're on-site and the raceway run hits an outside corner and you've spec'd the wrong width. The 2.86" (72.6mm) profile width is specific to LDPH5 — order the LDPH10 corner by mistake and it won't seat. That said, when you have the right part, the 600V rating means you're not splitting your run into separate duct systems at the corner for power vs. data, which simplifies both the install and the inspection documentation.

Technical Highlights:

  • 600V Rating: Handles full-power circuits alongside structured cabling in a single raceway pass — eliminating the need for separate conduit at corner transitions where power and data share the same wall run.
  • UL94V-0 Flame Rating: Self-extinguishing PVC construction meets the flame standard that AHJs enforce on raceway accessories in commercial occupancies — not just the duct body, but every fitting in the run.
  • Exact LDPH5/LDS5 Fit (72.6mm × 16.3mm): Tolerance-matched to the Pan-Way LDPH5 profile; no shimming, no field trimming. In finished commercial spaces, a gap at the corner fitting draws an inspection note — this eliminates that risk.

Deployment Considerations:

  • The OCFX5WH-X is compatible with LDPH5 and LDS5 only — confirm your installed duct width before placing an order. LDPH10 fittings are a different size and will not mate with LDPH5 base profiles.
  • PVC is interior-only. Don't route this fitting through exterior walls or in wet locations — the material is not UV-stabilized for outdoor exposure and carries no wet-location listing.

This fitting is the right spec for commercial security and AV integrators running Pan-Way LDPH5 raceway along perimeter walls in office, retail, or healthcare environments — where clean corner transitions and code-compliance documentation are both non-negotiable on the punch list.

Specifications
Sub Brand: Pan-Way™
Color: Blanco
Material: PVC
Height In: 0.64
Height Mm: 16.3
Width In: 2.86
Width Mm: 72.6
Product Type: Accesorios de control de radio de curvatura
Carton Qty: 0
Package Qty: 10
Standards: Ul94V-0, Ft4; cumple con las normas TIA/EIA; listado UL5A; cumple con UL.
Upc: 07498355655
Cable Category: wire-routing-management-protection
Q&A
Reviews
Have Questions?

Panduit 10PK Outside Corner Fitting LDPH5 LDS5

$57.60
$37.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources