Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv GL48WMCMM-W-SH-AF-CM 25U Wall-Mount Network Enclosure with Fan

Overview

The Vertiv GL48WMCMM-W-SH-AF-CM is a 25U wall-mount enclosure from the WMCM series, built for network equipment, patch panels, and active electronics in environments where floor space is at a premium. At 48 inches in overall height and fabricated from cold-rolled steel, this cabinet is designed to hold the weight and thermal demands of real working infrastructure — not just cable management. The integrated fan unit addresses the core problem with wall-mount enclosures: heat accumulation in a sealed space. If you've had switches or small UPS units throttle or fail in a sealed wall cabinet, the GL48WMCMM-W-SH-AF-CM addresses that directly.

The mesh door design works in tandem with the fan to promote airflow through the enclosure rather than trapping warm air behind a solid panel. This matters most in closets, server rooms without dedicated CRAC units, and IDF locations where ambient temperature control is inconsistent.

Key Features

  • 25U Capacity: 25 rack units in a wall-mount footprint — enough for a full IDF stack (patch panel, PoE switch, firewall, small UPS) without requiring a floor-standing rack. Eliminates the need for a full-depth equipment room in branch offices or remote sites.
  • Integrated Fan Unit: Active cooling built into the enclosure means you don't have to retrofit a fan tray or rely on passive convection. Sustained airflow keeps switching equipment and PoE injectors within operating temperature range during continuous operation.
  • Mesh Door Style: The mesh front door allows ambient air circulation even when the door is closed and latched — important for code-compliant installations where the cabinet must remain closed during operation. Reduces the temperature differential between inside and outside the enclosure.
  • Swing Handle Lock: The #12-24 threaded swing-handle locking mechanism provides tool-accessible security without requiring a key for authorized technicians, while still deterring casual tampering. Appropriate for IDF closets and telecommunications rooms with controlled access.
  • Cold-Rolled Steel Construction: Cold-rolled steel provides the structural rigidity needed to safely wall-mount loaded equipment — switches, patch panels, and cable management add up quickly. The material resists flex and deformation under sustained load, which matters when the cabinet is anchored to drywall-over-stud or concrete block.
  • #12-24 Mounting Holes: Standard #12-24 cage nut pattern is compatible with the overwhelming majority of rack-mount network equipment, eliminating the need for adapter rails or non-standard hardware. Your existing rack screws and cage nuts will work.
  • Wall-Mount Configuration: Purpose-built for wall installation rather than adapted from a floor-standing design — mounting points and weight distribution are engineered for vertical surface anchoring, reducing installation complexity and required floor clearance.
  • WMCM Series: Part of Vertiv's established WMCM wall-mount cabinet line, meaning replacement parts, accessory rails, and blanking panels from the series are interchangeable — relevant for multi-site deployments where standardization reduces spares inventory.

Integration & Compatibility

The GL48WMCMM-W-SH-AF-CM uses a standard #12-24 rack hole pattern, which is compatible with virtually all 19-inch rack-mount equipment including network switches, patch panels, fiber enclosures, small UPS units, and KVM devices. The 25U interior depth accommodates standard 1U through 4U equipment form factors commonly deployed in IDF and MDF configurations.

For network switches and PoE infrastructure deployments, the active fan unit is particularly relevant — high-density PoE switches dissipate significant heat under full port load, and passive wall enclosures are a known failure point in these installations. The integrated fan mitigates that risk without requiring a separate accessory purchase.

Wall-mount enclosures in this size class are commonly paired with horizontal cable management panels between each rack unit of equipment to maintain bend-radius compliance and reduce strain on RJ-45 ports. The standard hole spacing accommodates 1U cable managers without modification.

If your installation requires a floor-standing alternative — for deeper equipment, higher density, or seismic-rated installations — consider other enclosures in the Vertiv enclosure catalog. The WMCM wall-mount series is optimized for branch-office and IDF-closet scale, not high-density data center rows.

For facilities planning coverage area network infrastructure, this enclosure is well-suited to anchor a network infrastructure stack at a remote building or floor-level distribution point where a full equipment room is not available.

Frequently Asked Questions

Q: What rack unit capacity does the GL48WMCMM-W-SH-AF-CM provide?

A: The GL48WMCMM-W-SH-AF-CM provides 25U (rack units) of usable mounting space within a 48-inch overall height wall-mount enclosure.

Q: Does this enclosure include active cooling?

A: Yes. The GL48WMCMM-W-SH-AF-CM includes an integrated fan unit (AF designation in the model number), which provides active airflow through the enclosure to manage heat from installed network equipment.

Q: What type of rack mounting holes does the GL48WMCMM-W-SH-AF-CM use?

A: The enclosure uses standard #12-24 threaded mounting holes, compatible with the vast majority of 19-inch rack-mount network equipment and standard cage nut hardware.

Q: What is the door style and how does it affect airflow?

A: The GL48WMCMM-W-SH-AF-CM ships with a mesh door, which allows passive air circulation through the door panel even when closed and latched. Combined with the integrated fan, this helps maintain lower operating temperatures for installed equipment.

Q: What is the enclosure body made of?

A: The cabinet is fabricated from cold-rolled steel, which provides the structural rigidity required for a loaded wall-mount installation. Cold-rolled steel resists flex under the sustained weight of network switches, patch panels, and cable management.

Q: What locking mechanism does the GL48WMCMM-W-SH-AF-CM use?

A: The enclosure uses a swing-handle lock, providing secure tool-accessible closure appropriate for IDF closets and telecommunications rooms with controlled physical access.

James Everett
James Everett

The GL48WMCMM-W-SH-AF-CM is a 25U wall-mount I'd spec into branch-office IDF closets without hesitation — specifically because of the factory-integrated fan. Most wall-mount enclosures in this class ship passive, and integrators bolt on an aftermarket fan tray as an afterthought. Having the active fan built in from Vertiv means the airflow geometry is designed for the cabinet, not patched onto it. At 48 inches overall height in cold-rolled steel, this cabinet carries a real working load.

Technical Highlights:

  • 25U / 48-Inch Form Factor: Full IDF stack in a wall footprint — patch panel tier, PoE switch, firewall, and a 2U UPS fit comfortably without crowding the top or bottom of the rack space.
  • Integrated Fan (AF): Active cooling built into the enclosure design eliminates the need to specify, source, and install a separate fan tray — one less accessory to track and one less potential failure point in the cooling path.
  • #12-24 Threaded Holes: Standard cage-nut pattern means any rack-mount equipment on your BOM installs without adapter hardware. No surprises during commissioning.

Deployment Considerations:

  • Wall anchoring for a loaded 25U cabinet requires careful assessment of the wall substrate — concrete block or steel stud framing is strongly preferred over drywall-only applications. Verify the wall's load capacity before installation, especially with a full equipment stack plus cabling.
  • The mesh door provides airflow but does not offer the acoustic attenuation of a solid door — in open-office or classroom installations adjacent to occupied spaces, verify that fan noise meets the site's ambient noise requirements before committing to this model.

This enclosure is the right call for a multi-site retail or branch-office rollout where you need a standardized, thermally managed IDF cabinet at each location and floor space for a full rack simply isn't available. The WMCM series standardization also means your facilities team carries one spares profile across all sites.

Specifications
Store: Hours
Eccn: EAR99
Series: WMCM
Material: Cold Rolled Steel
Mounting Type: Wall
Type: Fan
Color: White
Door Style: Mesh
Lock Type: Swing Handle
Mounting Holes: #12-24
Rack Units: 25
Color Family: White
Dimensions: 48 in.
freight: 565.40
Q&A
Reviews
Have Questions?

Vertiv WM Premium 25UX24X32 FAN Gray - GL48WMCMM-W-SH-AF-CM

$2,830.00
$2,239.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources