Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv ITA2-10KRT208C 10kVA 3-Phase Rack UPS with SNMP

Overview

The Vertiv Liebert ITA2-10KRT208C is a 3-phase, 10kVA rack-mount uninterruptible power supply designed for mid-to-large commercial and data center environments requiring reliable 208V power protection. Where single-phase UPS units hit their ceiling, the ITA2-10KRT208C steps in to protect server racks, network infrastructure, and surveillance recording arrays that draw sustained three-phase loads. If your facility already runs 208V three-phase distribution — common in purpose-built data closets, colocation cages, and enterprise security operations centers — this unit plugs directly into that infrastructure without requiring transformer intervention. For broader power protection options, including single-phase and modular UPS solutions, the full Vertiv power portfolio covers a wide range of deployment scales.

Key Features

  • 8/10kVA Dual-Mode Power Rating: The ITA2-10KRT208C supports both 8kVA and 10kVA operating points, giving facilities flexibility to right-size load capacity without replacing the unit as demands grow incrementally. This matters in phased build-outs where rack densities increase over time.
  • 208/220V Input and Output Compatibility: Accepts 208V or 220V three-phase input and delivers the same on output — no auto-transformer required when integrating into standard North American three-phase panel infrastructure. Consistent output voltage protects sensitive switching and storage equipment from upstream fluctuation.
  • 93% Operating Efficiency: At 93% efficiency, this unit wastes significantly less energy as heat compared to legacy double-conversion UPS designs that often run at 85-88%. In a continuously powered environment, that difference translates directly to lower cooling load and reduced electricity cost over a three-to-five-year deployment cycle.
  • 4W+G Wiring Configuration: The four-wire-plus-ground wiring scheme is compatible with standard commercial three-phase panel terminations. Electricians familiar with 208V three-phase infrastructure will find the termination straightforward — no special adapters or custom wiring harnesses needed.
  • SNMP Network Management: Built-in SNMP support means your facilities or IT team can monitor UPS status, battery health, and load levels remotely through standard network management platforms. For network-integrated power monitoring, SNMP eliminates the need for a dedicated management card add-on.
  • Compact 130mm Profile: At 130mm depth (in the relevant dimension), the ITA2-10KRT208C fits in standard equipment racks without consuming excessive front-to-back real estate — relevant in dense rack configurations where NVR arrays, switches, and servers compete for the same U-space.

Integration and Compatibility

The ITA2-10KRT208C is suited for rack environments running 208V three-phase distribution, including enterprise network video recorder deployments, server closets, and security operations infrastructure. SNMP compatibility allows integration with most DCIM and network management platforms. Consult your facilities team to confirm panel ampacity and circuit protection sizing before installation — three-phase UPS installs require licensed electrical work in most jurisdictions.

Frequently Asked Questions

Q: What is the power rating of the ITA2-10KRT208C?

A: The ITA2-10KRT208C supports 8kVA and 10kVA operating modes, giving you flexibility as load requirements change.

Q: What input voltage does the ITA2-10KRT208C accept?

A: It accepts 208V or 220V three-phase input, compatible with standard North American commercial three-phase panel infrastructure.

Q: Does the ITA2-10KRT208C include SNMP for remote monitoring?

A: Yes. The ITA2-10KRT208C includes SNMP capability for remote monitoring of UPS status, battery condition, and load levels via standard network management platforms.

Q: What wiring configuration does the ITA2-10KRT208C use?

A: The unit uses a 4W+G (four-wire plus ground) configuration, standard for commercial three-phase installations.

Q: How efficient is the ITA2-10KRT208C?

A: The unit operates at 93% efficiency, reducing heat output and energy cost compared to lower-efficiency double-conversion designs.

Marty Allison
Marty Allison

The ITA2-10KRT208C sits in a specific and often underserved niche: facilities that have already committed to 208V three-phase distribution and need a rack-mount UPS that matches that infrastructure without conversion hardware. The 93% efficiency rating is the number I'd lead with — at 10kVA continuous, you're losing roughly 700W to heat at 93% versus over 1,200W at 88%, and that delta hits your HVAC sizing and energy bill every hour the unit runs.

Technical Highlights:

  • 8/10kVA Dual Rating: Operating at either 8kVA or 10kVA means you can deploy now at a lower load threshold and step up without a unit swap — useful in phased rack build-outs common in growing security NOCs.
  • 93% Efficiency: Compared to legacy double-conversion UPS designs running at 85-88%, the efficiency gain at sustained 10kVA load translates to measurable HVAC and utility savings over a three-to-five-year refresh cycle.
  • SNMP Integration: Native SNMP means the unit drops into existing network management platforms without proprietary software — facilities and IT teams can monitor battery state, load percentage, and fault conditions from the same dashboard as the rest of the rack gear.

Deployment Considerations:

  • Three-phase UPS installation requires licensed electrical work in most jurisdictions — confirm panel ampacity, circuit breaker sizing, and local code requirements before scheduling the install.
  • The 4W+G wiring scheme is standard, but verify your upstream distribution panel provides the correct phase configuration; mismatched phase sequencing on three-phase equipment can cause operational issues that are non-obvious during initial power-on.

This unit is a strong fit for enterprise security operations centers and colocation-adjacent deployments where 208V three-phase distribution is already in place and the facility team needs a manageable, network-visible UPS that doesn't require a separate management card investment to get remote visibility.

Specifications
Power Rating: 8/10kVA
Input Voltage Range: 208/220
Output Voltage Range: 208/220
Efficiency: 93%
Wiring: 4W+G
Dimensions: 130mm
Q&A
Reviews
Have Questions?

Vertiv Liebert ITA2 10K 3-PH Ups/snmp - ITA2-10KRT208C

$16,007.00
$10,976.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources