APC by Schneider Electric UNIFLAIR RETURN SUPL PLENUM - ACPL75159
Uniflair return supply plenum designed for specific environmental control system deployments
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The APC by Schneider Electric ACPL75160 is a Uniflair plenum chamber frame — a structural component used in in-row and end-of-row cooling architectures to channel and contain return or supply airflow between equipment racks and cooling units. At 1720mm wide and 305mm tall, this Frame Size 5 unit spans a full row segment, making it the right fit for data center operators building or extending a contained hot-aisle or cold-aisle plenum run. If your facility uses Uniflair in-row cooling and you're adding rack capacity or replacing a damaged frame section, the ACPL75160 is the structural piece that keeps the plenum sealed and airflow directed where it needs to go.
Browse the full APC by Schneider Electric catalog for compatible Uniflair cooling units, accessories, and UPS infrastructure.
The ACPL75160 is engineered for use within the APC Uniflair in-row cooling product family. Plenum frames in this line are paired with specific Uniflair cooling unit models based on row configuration, airflow direction (supply or return), and rack count per segment. This unit is designated for return/supply plenum duty — the product name specifies both orientations, indicating it functions as either a return or supply plenum frame depending on installation orientation and airflow design.
Before deploying, cross-reference the ACPL75160 frame size against your data center cooling design documentation or the Uniflair installation guide for your specific cooling units. Mismatched frame sizes result in gaps in the plenum seal, which undermines containment and forces the cooling units to work harder to maintain target supply temperatures. If you're configuring a new row from scratch, consult your Uniflair cooling unit documentation to confirm which frame SKUs are specified for your row length and unit count.
For complete rack infrastructure planning — including compatible power distribution units, cable management, and containment accessories — the APC ecosystem is designed to interoperate within a single row configuration without requiring third-party adapters.
Q: What cooling system is the ACPL75160 designed to work with?
A: The ACPL75160 is a Uniflair plenum chamber frame, designed for use with APC by Schneider Electric Uniflair in-row and end-of-row cooling systems. It is not a standalone cooling unit — it is a structural frame component that forms part of the airflow containment plenum in a Uniflair cooling row configuration.
Q: What does 'Frame Size 5' mean — how do I know if this is the right size?
A: APC's Uniflair plenum system uses frame size designations to match plenum frames to specific cooling unit models and row segment lengths. Frame Size 5 corresponds to specific Uniflair unit configurations. You should verify the required frame size in your Uniflair cooling unit's installation documentation or contact APC technical support with your cooling unit model number before ordering.
Q: Can the ACPL75160 be used for both supply and return plenum applications?
A: Based on the product designation ('Return/Supply Plenum'), the ACPL75160 frame is applicable to both return and supply plenum configurations depending on installation orientation and airflow design. Confirm the correct orientation for your row layout with your Uniflair system documentation.
Q: How heavy is the ACPL75160 and what are the installation requirements?
A: The ACPL75160 weighs 31.6kg (approximately 69.7 lbs). This is a substantial structural frame requiring two-person installation. Any overhead mounting structure or suspended ceiling grid must be verified to support this load prior to installation. The packaged unit ships at dimensions of 1753mm x 914mm x 330mm.
Q: What are the exact dimensions of the ACPL75160?
A: The ACPL75160 measures 1720mm wide, 305mm tall, with a maximum depth of 86.4cm (864mm). The shipping package measures 1753mm x 914mm x 330mm.

The ACPL75160 is one of those components that looks passive on a spec sheet but is load-bearing for cooling row performance. That 1720mm span width is the key number — it's sized to bridge a full row segment in the Uniflair architecture, so the plenum seal is continuous across the top of your rack run without a patchwork of shorter frames introducing gap leakage. I've seen facilities try to substitute generic plenum filler in these rows and then chase mysterious hot spots for weeks; the frame size matching in the Uniflair system exists for a reason.
Technical Highlights:
Deployment Considerations:
The ACPL75160 is the right call for facilities running Uniflair in-row cooling that are adding rack density to an existing row or replacing a damaged plenum frame section — anywhere that maintaining a tight return/supply air seal directly determines whether the cooling units can hold target supply temperatures under full rack load.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more APC by Schneider Electric products? Shop the full APC by Schneider Electric catalog →