APC by Schneider Electric UNIFLAIR MERV 11 BAG FILTER - ACPL75178
MERV 11 bag filter designed for integration into UNIFLAIR air handling units
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The ACPL75183 is a MERV 11 bag filter component designed for use with APC by Schneider Electric Uniflair precision cooling systems. If you're maintaining a Uniflair unit in a data center or equipment room and need a replacement plenum-chamber filter rated to MERV 11, this is the part to order — not a generic filter that approximates the fit, but the purpose-built component sized to Frame Size 8 and finished in white to match the Uniflair housing.
Maintaining correct filtration in a precision cooling unit is not optional infrastructure work. A clogged or undersized filter starves the unit of airflow, forces compressors and fans to work harder, and shortens equipment life. Using the correct OEM-matched replacement like the ACPL75183 ensures the filter seats properly in the plenum frame and maintains rated airflow resistance characteristics rather than creating bypass gaps that defeat the filtration purpose entirely.
The ACPL75183 is a replacement filter component for APC by Schneider Electric Uniflair precision cooling units that use a Frame Size 8 plenum configuration. It is not a universal data center filter and is not designed for use in third-party cooling systems or standard HVAC applications. Before ordering, verify the plenum frame size specification in your Uniflair unit's documentation. If you are managing a larger fleet of Uniflair units across a data center, consult the Uniflair maintenance schedule to determine the recommended filter replacement interval for your environment's particulate load — higher-dust environments will require more frequent changes regardless of the MERV rating.
For facilities teams managing data center infrastructure maintenance programs, keeping a spare ACPL75183 on hand avoids the risk of running a cooling unit with a saturated filter while waiting for a replacement to ship. Cooling unit downtime in a live data center environment carries costs that far exceed the filter component price.
Q: What MERV rating is the ACPL75183?
A: The ACPL75183 carries a MERV 11 rating, which targets particles in the 1–10 micron range and is appropriate for data center and equipment room precision cooling applications.
Q: What frame size does the ACPL75183 fit?
A: The ACPL75183 is built for Frame Size 8 plenum chambers. Verify your Uniflair unit's plenum frame size before ordering — this filter is not universal across all Uniflair models.
Q: Is the ACPL75183 a bag filter or a flat panel filter?
A: It is a bag filter. Bag construction provides greater media surface area than flat-panel alternatives of the same face size, resulting in lower pressure drop and longer service intervals.
Q: Can the ACPL75183 be used in standard building HVAC systems?
A: No. The ACPL75183 is an OEM replacement component designed specifically for compatible APC by Schneider Electric Uniflair precision cooling units. It is not intended for standard HVAC ductwork or third-party cooling systems.
Q: Why use the OEM filter instead of a generic MERV 11 replacement?
A: The OEM-matched Frame Size 8 geometry ensures the filter media seats fully in the plenum opening without edge gaps. Aftermarket filters that don't conform to the exact frame size can allow bypass airflow that carries particulates directly to the cooling coils, defeating the filtration purpose and potentially compromising your Uniflair maintenance agreement.

The ACPL75183 is one of those parts that doesn't get attention until the cooling unit starts alarming — and that's exactly the wrong time to discover you don't have a spare on the shelf. As a MERV 11 bag filter sized to Frame Size 8, it's a precise match for the Uniflair plenum chamber it was designed for, and there's no good substitute if your unit requires it.
Technical Highlights:
Deployment Considerations:
The ACPL75183 belongs in the maintenance stock of any facility running Frame Size 8 Uniflair cooling units in a production data center — order it before you need it, not during an active thermal event.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more APC by Schneider Electric products? Shop the full APC by Schneider Electric catalog →