Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit U06N11V SteadySine 6KVA 3U Rack UPS 208/240V

Overview

The Panduit U06N11V is a 6KVA, 3U rack-mount uninterruptible power supply from the SteadySine™ lineup, built for 208/240V single-phase environments where clean, conditioned power is non-negotiable. Sized at 3U rack height (10.3 in / 262 mm tall, 17.3 in / 440 mm wide), it drops into a standard 19-inch rack without consuming excessive vertical real estate — a real consideration when you're stacking compute, storage, and networking in a dense edge cabinet or primary data center row. The U06N11V targets data center, edge, and enterprise multi-tenant data center (MTDC) deployments where an unplanned outage means service interruption, not just inconvenience.

Panduit positions this UPS within their Panduit power and infrastructure catalog alongside structured cabling, cable management, and rack power distribution — which matters if you're building or retrofitting a full rack UPS and power protection infrastructure from a single vendor relationship.

Key Features

  • 6KVA Capacity at 208/240V: Supports single-phase 208V or 240V input, the standard for rackmount IT equipment in North American data centers. At 6KVA, this unit can back up a moderately loaded server rack — think 2–4 1U servers plus networking — giving you enough runtime buffer to initiate a clean shutdown or ride out a brief utility fluctuation without data loss.
  • SteadySine™ Output Waveform: The SteadySine™ branding signals a pure sine wave output on battery — not the modified or stepped waveform cheaper UPS units produce. This matters for active PFC power supplies (standard in modern servers and storage arrays): a non-sine waveform causes those supplies to fault or run hot. If your load includes any server-class hardware built after roughly 2010, you want true sine wave on battery, and the U06N11V delivers it.
  • 3U Form Factor — Dense Without Sacrificing Capacity: At 3U, the U06N11V occupies less vertical space than many comparable 6KVA units. In a 42U cabinet with tight real estate, saving a unit of rack height translates directly to more room for compute or switching. Dimensions of 17.3 in wide × 10.3 in tall fit the standard EIA-310 19-inch rack without side-bracket extensions.
  • Data Center, Edge, and MTDC Application Rating: Panduit explicitly rates the U06N11V for three distinct deployment contexts — primary data center rows, edge locations (branch offices, remote IDF/MDF, factory floors), and enterprise MTDC environments. That range means you can standardize on a single UPS SKU across a distributed infrastructure rather than spec-ing different units per site type.
  • Single-Phase Architecture: Single-phase 208/240V simplifies installation — no three-phase PDU or specialized electrician work required in most commercial buildings. If your facility already runs single-phase 208V circuits to the rack (common in smaller data rooms and edge closets), the U06N11V installs without an electrical infrastructure upgrade.
  • Competitive Displacement Positioning: Panduit lists comparable models from Eaton (9PX6K, 9PX6KTF5), Liebert (GXT5-6KL630RT5UXLN), APC (SRT6KRMXLT), Tripp Lite (SU6KRT3UG), and Cyber Power (UDC9606H-RT ONE) as cross-references. If you're replacing or standardizing away from any of those platforms, the U06N11V is the Panduit equivalent SKU to evaluate side-by-side.

Integration & Compatibility

The U06N11V integrates into data center power infrastructure alongside Panduit's rack PDUs, cable management, and enclosure systems. As a 208/240V single-phase unit, it pairs naturally with standard North American rackmount PDUs wired for those voltages. For environments running a mix of 120V and 208V loads, confirm downstream PDU compatibility before deployment — the U06N11V operates at 208/240V, not 120V. If your existing rack power distribution is already 208V-wired, no additional conversion hardware is needed between the UPS output and your PDUs.

Panduit's cross-reference list (Eaton 9PX6K, APC SRT6KRMXLT, Liebert GXT5, Tripp Lite SU6KRT3UG, CyberPower UDC9606H-RT ONE) gives a clear signal on competitive equivalence — use those model numbers as a benchmark for runtime curves, efficiency ratings, and management card options when doing a side-by-side evaluation.

Frequently Asked Questions

Q: What input voltage does the Panduit U06N11V require?

A: The U06N11V is designed for single-phase 208/240V input, standard in North American data center and commercial building environments. It is not a 120V unit.

Q: Is the U06N11V a true sine wave UPS?

A: Yes. The SteadySine™ designation indicates a pure sine wave output on battery, which is required for active PFC power supplies found in modern servers and storage equipment.

Q: How much rack space does the U06N11V occupy?

A: The U06N11V occupies 3U (10.3 inches / 262 mm tall) and is 17.3 inches (440 mm) wide, fitting standard 19-inch EIA-310 rack enclosures.

Q: What deployment environments is the U06N11V rated for?

A: Panduit rates the U06N11V for data center, edge, and enterprise multi-tenant data center (MTDC) applications — making it suitable for primary data rooms, branch/edge closets, and colocation environments.

Q: Which competitive UPS models does the U06N11V replace or compare to?

A: Panduit cross-references the U06N11V against the Eaton 9PX6K and 9PX6KTF5, Liebert GXT5-6KL630RT5UXLN, APC SRT6KRMXLT, Tripp Lite SU6KRT3UG, and CyberPower UDC9606H-RT ONE. These are the direct competitive equivalents at the 6KVA single-phase tier.

Q: What is the package quantity for the U06N11V?

A: The U06N11V ships as a single unit (package quantity: 1).

Ted Perry
Ted Perry

The U06N11V sits at the 6KVA tier in Panduit's SteadySine™ rack UPS line — a capacity point that covers a realistic single-rack compute load at 208/240V single-phase without stepping up to a larger, more complex three-phase footprint. The 3U chassis keeps the vertical footprint honest, which I appreciate when I'm laying out a 42U edge cabinet where every unit of height is contested between compute, switching, and cable management.

Technical Highlights:

  • SteadySine™ Pure Sine Output: Pure sine wave on battery is not optional with modern server hardware — active PFC supplies will fault or throttle on stepped-approximation waveforms. The SteadySine™ designation confirms this unit delivers clean output, not a compromise waveform.
  • 3U / 10.3-inch Height: At 10.3 in (262 mm) tall and 17.3 in (440 mm) wide, the U06N11V fits any standard 19-inch rack without rail extensions or shelf adapters. Competitors at this KVA tier sometimes push 4U or require external battery modules; 3U self-contained is the better rack story.
  • 208/240V Single-Phase Input: This is a purpose-built unit for the North American 208V data center environment — not a dual-voltage universal unit with a tap switch. That specificity is a feature: fewer failure modes, simpler installation qualification, no voltage-configuration errors in the field.

Deployment Considerations:

  • Confirm your facility's branch circuits are wired for 208V (or 240V single-phase) before the unit ships. This is not a 120V UPS — plugging into a standard NEMA 5-15 or 5-20 circuit will not work. Most purpose-built data rooms and colocation cages are already 208V, but branch offices and edge closets sometimes run 120V only.
  • Panduit's cross-reference list (Eaton 9PX6K, APC SRT6KRMXLT, Liebert GXT5) gives you a runtime/efficiency comparison baseline — but verify those competitors' actual runtime curves at your specific load before treating them as interchangeable. KVA ratings match; battery runtime at 50% load may differ meaningfully by model.

Best fit: a primary data center or enterprise edge rack running 208V single-phase with 2–5 kW of active IT load, where pure sine wave output on battery and a compact 3U chassis are both hard requirements and you want a single-vendor Panduit infrastructure stack from cable tray to UPS.

Specifications
Sub Brand: SteadySine™
Application: Data Center, Edge, Enterprise MTDC
Height In: 10.3
Height Mm: 262
Width In: 17.3
Width Mm: 440
Product Type: UPS
Carton Qty: 0
Package Qty: 1
Upc: 61305682528
Cable Category: power-distribution-environmental-connectivity-hardware
Type: UPS
Q&A
Reviews
Have Questions?

Panduit SZ UPS 6KVA 3U 208/240V Singlea

$5,420.41
$4,914.99

RELATED PRODUCTS

Save $3,610.03
Panduit SZ UPS 10KVA 4U 208/240V Lion Spd-c/rk PK1
Add to Cart The item has been added

Panduit U10N11L

Panduit SZ UPS 10KVA 4U 208/240V Lion Spd-c/rk PK1

10 kVA rack-mount uninterruptible power supply from the SteadySine™ product family, designed for commercial and enterprise environments where clean

    Usually Ships in 2-3 Weeks Free shipping over $499
    $19,254.02 $15,643.99 Save $3,610.03
    The item has been added Add to quote
    $19,254.02 $15,643.99 Save $3,610.03
    Save $3,610.03 Add to cart Add to quote

    System Design, Deployment & Technical Support

    Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

    Fixed scope • Fixed price

    System Design Assistance

    • Get help validating product compatibility
    • Coverage requirements
    • Storage planning and deployment architecture before you buy.
    Request Design Help

    Deployment & Configuration Support

    • Access fixed-scope support for rollout planning
    • User setup guidance
    • Migration and system standardization across single-site or multi-site deployments
    View Support Services

    Guides, Tools & Calculators

    • PoE requirements
    • Storage retention
    • Camera selection and deployment methodology
    Open Technical Resources