Overview
Panduit STD Rack 84IN High 2134MM
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Bundle Summary
Overview
No Bots, Just Experts
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Panduit R2P 45U 2-Post Open Frame Rack
Overview
The Panduit R2P is a 45U, 84-inch (2,134 mm) tall two-post open-frame rack built for telecommunications and data center equipment mounting where access from all sides matters more than enclosed security. At 20.3 inches (516 mm) wide, the R2P accommodates standard 19-inch (48.3 cm) EIA-format gear — switches, patch panels, cable managers, and similar infrastructure — while keeping the footprint narrow enough for dense row deployments or auxiliary wiring closets. The extruded aluminum channel construction keeps the unit weight manageable without sacrificing the 453.6 kg (1,000 lb) static load rating that matters when fully loaded with patch panels and heavy switching gear. If your environment calls for an open two-post foundation rather than a four-post enclosed cabinet, the R2P is the straightforward, UL-listed choice from Panduit's infrastructure line.
Key Features
- 45U Capacity at 84 Inches: 45 rack units of usable space in a 2,134 mm column — enough to run a fully populated patch field, multiple managed switches, and cable management without stacking racks side by side. For wiring closets with limited floor space, this height-to-unit ratio is efficient.
- EIA/ECA-310-E #12-24 Threaded Rails: Industry-standard #12-24 threaded hole pattern means off-the-shelf cage nuts are not required — equipment mounts directly with standard rack screws. Universal hole spacing eliminates the guesswork of matching hole patterns when mixing vendors across the same rack.
- Bottom-to-Top Unit Numbering: Rails are numbered in ascending order from bottom to top, which matches the convention most network engineers and documentation standards expect. This reduces cabling errors during initial installation and simplifies future moves, adds, and changes.
- Extruded Aluminum Construction: Aluminum extrusion versus welded steel sheet means consistent channel geometry and lighter handling during installation. The powder-coat finish in black provides corrosion resistance in conditioned indoor environments.
- 76.2 mm Rail Depth: The 3-inch mounting depth is sufficient for most passive and 1U active equipment. Note this is a two-post open rack — deep chassis servers and high-depth switches require a four-post configuration; this product is suited for patch panels, switches up to moderate depth, and cable management infrastructure.
- UL 2416 Listed, 453.6 kg Load Rating: UL 2416 listing for open racks and cabinets confirms the structural rating has been independently verified. A 1,000 lb capacity means you can fully populate all 45U with dense copper patch panels and 1U switches without approaching the structural limit.
- RoHS Compliant: EIA/ECA-310-E and RoHS compliance keeps the R2P within the material restrictions required for projects with environmental compliance mandates — relevant for government, education, and EU-destined installations.
- Broad Cable Management Compatibility: Panduit publishes a range of compatible horizontal and vertical cable managers for this platform. Specifying accessories from the same product family reduces fitment risk when ordering cable routing hardware.
Integration & Compatibility
The R2P is designed around the EIA/ECA-310-E standard, making it compatible with any 19-inch rack-mount equipment — patch panels, 1U switches, media converters, power strips, and cable managers from any manufacturer conforming to that standard. The #12-24 threaded rail pattern is the dominant convention in North American network infrastructure, so existing rack hardware from virtually any vendor will mount without modification. Panduit's catalog of vertical and horizontal cable management accessories integrates directly with this platform. Because this is an open two-post rack, enclosed-cabinet accessories (blanking panels for front-door airflow, side panels, door locks) are not applicable — plan your physical security and airflow strategy accordingly if the deployment environment requires it.
Frequently Asked Questions
Q: What is the load capacity of the Panduit R2P?
A: The R2P is UL 2416 listed for 453.6 kg (1,000 lb) static load, which is sufficient for fully populated patch panels and switching gear across all 45U.
Q: What hole pattern do the R2P rails use?
A: The R2P uses EIA #12-24 threaded rails with universal EIA/ECA-310-E hole spacing. Standard rack screws mount directly — no cage nuts required.
Q: Is the R2P suitable for deep servers or blade chassis?
A: No. The R2P is a two-post open rack with 76.2 mm (3-inch) rail depth. It is designed for patch panels, 1U switches, and similar shallow-to-moderate-depth equipment. Deep 2U+ servers and blade chassis require a four-post rack or enclosed cabinet.
Q: What standards does the R2P meet?
A: The R2P meets UL 2416 and EIA/ECA-310-E, and is RoHS compliant.
Q: What finish and color does the R2P come in?
A: The R2P is black with a powder-coat finish over extruded aluminum construction.
Q: Does the R2P include cable management accessories?
A: Cable management is not included in the base unit. Panduit offers a range of compatible horizontal and vertical cable managers sold separately for this platform.

The Panduit R2P's UL 2416 listing at a verified 453.6 kg (1,000 lb) static capacity is the detail I look at first on any two-post open rack. It tells you the structure has been independently tested — not just marketed — which matters when you're stacking 45U of copper patch panels in a wiring closet that nobody will re-rack for five years.
Technical Highlights:
- EIA #12-24 Threaded Rails: Direct-thread mounting eliminates cage nut procurement and installation steps — on a 45U build that can save 30–45 minutes of rack prep time before the first panel goes in.
- 2,134 mm / 45U Column Height: The 84-inch height gives you a full 45U of usable space. In a standard 9-foot wiring closet this leaves working clearance at the top; in a low-ceiling IDF you may want to confirm ceiling height before ordering.
- Extruded Aluminum with Powder Coat: Aluminum extrusion holds dimensional tolerances better than welded sheet steel at this price point, which means the rail-to-rail spacing stays consistent top to bottom — important when you're mounting high-density patch panels that are sensitive to even small positional variations.
Deployment Considerations:
- The 76.2 mm (3-inch) rail depth is a hard constraint — any equipment with a mounting depth beyond 3 inches requires a four-post solution. Verify chassis mounting depth before specifying this rack for active switching equipment.
- Open two-post racks provide no physical access control; if your closet or room does not have its own door lock, plan a separate physical security layer — the R2P itself offers no locking panels or doors.
The R2P is the right call for structured cabling termination rooms and IDF wiring closets where the load is predominantly patch panels, 1U switches, and horizontal cable managers — environments where open access from all sides speeds moves and adds, and where enclosed cabinet cost is not justified by the security or airflow requirements.
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Bundle Summary
Looking for more Panduit products? Shop the full Panduit catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology