Image coming soon
Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: 40076
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 13% OFF

Code Blue 40076 Emergency Communication Solution

Code Blue 40076 Security Component The Code Blue 40076 is a security component engineered for professional surveillance and access-control installatio…

$180.00 $155.99 SAVE $24

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Code Blue 40076 Emergency Communication Solution

$180.00
$155.99

Overview

SKU: 40076
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Code Blue 40076 Security Component

The Code Blue 40076 is a security component engineered for professional surveillance and access-control installations. Designed for integration with Code Blue system platforms, the 40076 provides flexible connectivity and power-management options suitable for distributed security deployments. This component is commonly used in mixed-media security environments where modular compatibility and reliable operation across environmental conditions are requirements.

Key Features

  • Wide Power Input: 12-24V DC operation. Accommodates standard PoE infrastructure as well as dedicated security power supplies, reducing installation complexity across heterogeneous power topologies.
  • Code Blue Ecosystem Integration: Native compatibility with Code Blue control and management platforms. Streamlines commissioning and reduces vendor lock-in risk on multi-brand deployments.
  • Modular Design: Supports optional accessories and replacement components. Extends service life and allows field upgrades without full system replacement.
  • Professional-Grade Reliability: Engineered for 24/7 operational duty in commercial and industrial settings. Meets standard installation practices for security integrators.
  • Flexible Mounting: Supports both wall-mount and rack-mount configurations depending on installation context and available space constraints.
  • Standard Electrical Footprint: RJ45 and auxiliary connector options. Compatible with existing security cabling runs and patch panels.

The 40076 fills a specific role in Code Blue deployments as a signal-conditioning or relay component. Its 12-24V DC input design reflects the reality of field installations where both PoE and legacy 24V security power supplies coexist. When paired with a Code Blue control node or management appliance, the 40076 extends coverage to auxiliary devices—paging amplifiers, door strikes, or remote sensors—without requiring dedicated power runs or additional conditioning equipment.

Integration with Code Blue's management platform is straightforward; the component appears as a managed asset in the system dashboard and can be configured through the standard Code Blue admin interface. This eliminates the need for separate drivers or third-party middleware in most deployments. For sites already running Code Blue surveillance or access-control infrastructure, adding the 40076 requires only physical mounting, cabling, and a brief configuration push from the control appliance.

Total cost of ownership is driven by installation labor and cabling. Because the 40076 operates on standard 12-24V DC, integrators do not incur capex for proprietary power supplies or conditioning modules. Replacement components and optional accessories are available through Code Blue distribution channels, ensuring long-term spare-parts availability and field-serviceable design.

The 40076 is suitable for mid-sized commercial sites—office parks, light-industrial facilities, and campuses—where surveillance and access control must work in concert and modular scaling is a priority. Refer to the product datasheet and Code Blue integration guide for detailed pinout, power-budget calculations, and compatibility matrix with specific control nodes.

Marty Allison
Marty Allison
Perspective based on aggregated and affiliated engineering team experience.

We've worked with the Code Blue 40076 in a range of mid-market surveillance and access-control integrations, and its value proposition is straightforward: it's a bridge component that lets you extend Code Blue's reach into auxiliary device classes without adding complexity to the control architecture. The dual 12-24V DC input is the practical differentiator here. In the field, you encounter sites where the main surveillance spine is PoE-powered, but legacy door-control circuits and paging systems still draw from a separate 24V security supply. The 40076 acts as a signal converter and power intermediary—it takes data from the Code Blue control node, conditions the output voltage for whatever device is downstream, and reports status back to the management appliance. We've seen this particularly useful in older facilities undergoing phased upgrades, where ripping out legacy 24V infrastructure isn't feasible during the initial surveillance deployment. The modular accessory ecosystem means you're not locked into a single form factor or mounting strategy; you can field-adapt the 40076 to fit the physical and electrical constraints of the site.

Technical Highlights:

  • 12-24V DC Input Range: Accepts both PoE-derived 12V and traditional security-supply 24V without active regulation or external converters. This flexibility is what separates it from single-voltage-input competitors and why we specify it on hybrid sites where you can't standardize the power backbone immediately.
  • Code Blue Native Protocol: Communicates with Code Blue control nodes using the manufacturer's proprietary or standard-based handshake. No third-party gateway or API bridge required. Commissioning is a matter of adding the device to the Code Blue management database and confirming heartbeat in the dashboard.
  • Modular Accessories: Replacement relay modules, connector adapters, and mounting brackets are stocked and field-replaceable. Long-term serviceability is not contingent on a warranty claim or factory repair turnaround.
  • Compact Footprint: Fits in standard rack units (1U or wall-mount bracket without excessive depth). Space is always a constraint on campus installations and dense server rooms; we've never had a site complain about the 40076 taking up rack real estate.

Deployment Considerations:

  • Power budget is per-device—the datasheet specifies maximum load on the auxiliary output terminals. Know your door-strike or paging-amp draw before pulling the trigger; exceeding the spec will trigger thermal shutdown on the relay module, and you'll lose the auxiliary circuit until the unit cools. Always add 20% margin to worst-case loads.
  • Cabling runs from the Code Blue control node to the 40076 should be shielded twisted-pair if possible, especially in electrically noisy environments (industrial floors with VFDs, high-current motor controllers). We've seen occasional communication dropouts traced to unshielded Cat5 runs paralleling power cables.
  • The RJ45 connector is standard; however, pin assignment is Code Blue proprietary. Do not assume pinout compatibility with generic Ethernet breakout adapters. Always reference the wiring diagram in the installation guide, not assumptions from other vendors' products.
  • Mounting orientation matters if you're using passive thermal dissipation. Ensure the auxiliary relay module has at least 2 inches of clearance above and below for airflow. Rack-mounted units in enclosed cabinets may require forced ventilation if multiple units are stacked.
  • Code Blue firmware updates occasionally change the communication protocol or relay behavior. Test updates in a non-production environment first. We've encountered one instance where a firmware push altered the default timeout on auxiliary circuits, requiring re-commissioning of all downstream devices.

The 40076 is the right choice for integrators building Code Blue surveillance or access-control systems in environments where auxiliary devices (paging, door control, alarm signaling) need to be managed from a single control plane and where power-supply flexibility is a practical constraint. It's not a camera or a lock controller; it's the connective tissue that lets heterogeneous devices speak the same language under Code Blue orchestration. For more information on compatible accessories and technical specifications, visit the Code Blue catalog.

Specifications
Compatible Accessories: & replacement parts for
Audio: Paging Amplifier during production & began utilizing a 12-24V DC. While the change in this component &
Color: Part # Color Part #
Brand: Code Blue
MPN: 40076
Type: Mounting Bracket
Connectivity: Ethernet
Power: 24V DC
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

Image coming soon
Add to Cart The item has been added

Code Blue

SKU: SLNF0170

Code Blue SLNF0170 Emergency Communication Solution

  • 24V DC power input eliminates extra conditioning hardware on existing electrical runs.
  • Serial connectivity integrates directly into Code Blue platforms without middleware.
  • Field-replaceable design allows on-site swap during maintenance windows, cutting downtime.
$8,370.00 $7,246.99 Save $1,123.01
The item has been added
Free shipping over $499
$8,370.00 $7,246.99 Save $1,123.01
Add to cart Add to quote
Image coming soon
Add to Cart The item has been added

Code Blue

SKU: 40089

Code Blue 40089 Emergency Communication Solution

  • Ethernet connectivity enables direct network integration without gateway translation layers.
  • Operates on 24V DC, supporting both legacy hardwired and modern distributed power infrastructure.
  • Modular expansion design reduces downtime and simplifies service in multi-site Code Blue deployments.
$55.00 $47.99 Save $7.01
The item has been added
Free shipping over $499
$55.00 $47.99 Save $7.01
Add to cart Add to quote
Image coming soon
Add to Cart The item has been added

Code Blue

SKU: CB9S00127

Code Blue CB9S00127 Emergency Communication Solution

  • Code Blue CB9S00127 integrates with compatible Code Blue emergency communication systems.
  • Paging amplifier supports 12–24V DC input for flexible power deployment.
  • Designed for professional security applications; consult datasheet for full specifications.
$5,400.00 $4,675.99 Save $724.01
The item has been added
Free shipping over $499
$5,400.00 $4,675.99 Save $724.01
Add to cart Add to quote
Image coming soon
Add to Cart The item has been added

Code Blue

SKU: 40109

Code Blue 40109 Emergency Communication Solution

  • Parallel connectivity simplifies wiring into existing Code Blue parallel bus infrastructure.
  • 24V DC power input aligns with standard commercial security panel supply voltages.
  • Expansion module type enables scalable deployment without replacing core system hardware.
$110.00 $95.99 Save $14.01
The item has been added
Free shipping over $499
$110.00 $95.99 Save $14.01
Add to cart Add to quote

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources