Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: VP5N30A0
Condition: New
Write a Review 31% OFF

Vertiv Rpdu Switched Unit Level Monitoring EC 30A 120/208V WYE 8.6KW Vertical (18 - VP5N30A0

Vertiv VP5N30A0 Switched 0U Vertical Rack PDU with Unit-Level MonitoringOverviewThe Vertiv VP5N30A0 is a Geist-platform switched rack PDU designed for…

$2,273.00 $1,558.99 SAVE $714
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Vertiv Rpdu Switched Unit Level Monitoring EC 30A 120/208V WYE 8.6KW Vertical (18 - VP5N30A0

$2,273.00
$1,558.99

Overview

SKU: VP5N30A0
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv VP5N30A0 Switched 0U Vertical Rack PDU with Unit-Level Monitoring

Overview

The Vertiv VP5N30A0 is a Geist-platform switched rack PDU designed for data center and enterprise server rooms where remote outlet-level control and real-time power monitoring are non-negotiable. Rated at 30A input with an 8.6kVA capacity, this 0U vertical unit delivers 120/208V WYE power to a high-density mix of 18 locking IEC C13 and 6 locking IEC C19 outlets — covering everything from 1U servers to dense storage arrays and UPS bypass loads. The vertical 0U form factor mounts in the rear rail channel of standard open-frame and enclosed racks, preserving every U of front rack space for active equipment.

Built on Vertiv's Geist monitoring platform, the VP5N30A0 goes beyond basic switched PDUs by combining outlet-level switching, input power monitoring, environmental sensor support, and a hot-swappable intelligence module into a single unit. If your data center operations team needs granular remote power control without dispatching a technician to the floor, this is the architecture to deploy.

Key Features

  • Outlet-Level Switching with Bi-Stable Latching Relays: Each outlet can be individually toggled, cycled, or sequenced remotely — latching relays hold their state through a monitoring device failure, so a network outage won't bounce your servers. Critical for IT teams managing distributed or unmanned remote edge sites.
  • 30A / 8.6kVA Input Capacity: Sized for a half-loaded 42U rack of mid-range servers or a fully loaded 24U dense-storage configuration. The NEMA L21-30P input plug mates directly to standard 208V 3-phase PDU circuits found in most purpose-built data centers — no adapters, no re-wiring.
  • 18x Locking IEC C13 + 6x Locking IEC C19 Outlets: The locking mechanism prevents accidental disconnects under vibration or cable movement — a real concern in high-density racks where cable management is tight. C19 positions handle high-draw devices like 2U rack servers, blade chassis power supplies, and network core switches drawing up to 16A per outlet.
  • Dual Ethernet Ports: Two independent network interfaces let you daisy-chain PDU monitoring across a rack row without running separate network drops to each unit, or assign primary and secondary management paths for redundancy. Either way, you're not adding switch port consumption to every PDU in the room.
  • Hot-Swappable Monitoring Device: The intelligence module can be replaced without cutting power to connected equipment — useful when a firmware issue or hardware fault hits the monitoring card and you need to swap it during business hours without a maintenance window.
  • Environmental Sensor Port: Attach temperature and humidity probes directly to the PDU and surface those readings through the same management interface as power data. Consolidates rack-level environmental monitoring without deploying separate sensor hardware or management infrastructure.
  • Input Power Monitoring: Real-time kW draw at the PDU level lets capacity planners track actual versus allocated load across the row. Helps avoid the common scenario of discovering you've over-subscribed a circuit only after a breaker trips.
  • TAA-Compliant: Sourced in compliance with the Trade Agreements Act — cleared for federal government procurement, SLED contracts, and any program requiring domestic or designated-country manufacturing.
  • Five-Year Limited Warranty: Vertiv backs this unit with a five-year limited warranty, which is notably longer than the two-to-three year terms common on competing switched PDUs at this price tier.

Integration and Compatibility

The VP5N30A0 mounts in the rear vertical channel of standard 19-inch and 23-inch open-frame racks and enclosed cabinets using the 0U bracket system. The NEMA L21-30P plug connects to 208V WYE 30A circuits, which are standard in most purpose-built data centers and colocation environments. Dual Ethernet ports support daisy-chaining across a PDU row, reducing the per-PDU management network overhead. The environmental sensor port supports Vertiv Geist-compatible temperature and humidity probes, enabling rack-level environmental data through the native management interface. Standards compliance includes RoHS, UL and c-UL Listed 60950, and FCC Part 15 Class A — covering both safety and emissions requirements for North American data center deployments. The Geist sub-brand platform integrates with common DCIM tools via standard protocols, making it compatible with most enterprise power management workflows without requiring proprietary software licenses.

Frequently Asked Questions

Q: Is the VP5N30A0 TAA-compliant for government procurement?

A: Yes. The VP5N30A0 is TAA-compliant, making it eligible for federal, state, and local government contracts that require Trade Agreements Act sourcing.

Q: What input plug does the VP5N30A0 use?

A: The VP5N30A0 uses a NEMA L21-30P input plug, rated at 30A for 120/208V WYE circuits — standard in purpose-built data centers and colocation facilities.

Q: Can I replace the monitoring module without powering down connected equipment?

A: Yes. The VP5N30A0 features a hot-swappable monitoring device, so the intelligence card can be swapped without interrupting power to any connected outlet.

Q: What is the warranty on the VP5N30A0?

A: Vertiv provides a five-year limited warranty on the VP5N30A0 — longer than the two-to-three year terms typical at this PDU tier.

Q: How many outlets does the VP5N30A0 provide, and what types?

A: The VP5N30A0 provides 24 total outlets: 18 locking IEC C13 outlets and 6 locking IEC C19 outlets. All feature locking mechanisms to prevent accidental disconnection.

Q: Does the VP5N30A0 support environmental monitoring?

A: Yes. It includes a dedicated environmental sensor port for attaching compatible temperature and humidity probes, surfacing those readings through the same management interface as power data.

Karl Wilson
Karl Wilson

The VP5N30A0 is the unit I reach for when a customer needs outlet-level switching on a 208V WYE feed without giving up any rack U-space — that 0U vertical form factor is genuinely useful in fully-loaded 42U deployments where you can't afford to burn even 1U on a horizontal PDU. The bi-stable latching relay design is the spec I always call out first: if the monitoring card loses network or crashes, the relays stay in their last commanded state rather than defaulting open and dropping your servers. That's not a given on every switched PDU at this price point.

Technical Highlights:

  • Bi-Stable Latching Relays: Outlets retain their last commanded state (on or off) through a monitoring device failure — prevents unintended server reboots during network incidents or PDU firmware faults.
  • Hot-Swappable Monitoring Module: Intelligence card replacement happens live, without cutting the 30A feed — critical for 24/7 environments where a monitoring card failure can't wait for a scheduled maintenance window.
  • Dual Ethernet with Daisy-Chain Support: Run a single network drop to the first PDU in a row and chain subsequent units — reduces switch port consumption and cabling overhead in multi-PDU row deployments.

Deployment Considerations:

  • The NEMA L21-30P input requires a 208V WYE 30A circuit — confirm your PDU whip or in-row power panel has that circuit type before ordering. This is not a NEMA 5-30 or L6-30 application.
  • The C19 outlets support high-draw devices but there are only 6 of them — if your rack is dense with dual-corded blade chassis or high-power storage controllers, map your C19 demand before assuming 6 positions are sufficient. You may need a second PDU or a model with a different outlet mix.

For a colocation or enterprise data center row running a mix of 1U rack servers on C13 and blade or storage on C19 — with remote operations staff who need granular per-outlet control without an on-site technician — the VP5N30A0 is a well-matched fit. It's also a clean choice for federal and SLED deployments where TAA compliance is a contract requirement, not an afterthought.

Specifications
Mount Type: Rack
Sub Brand: Geist
Product Type: Rack PDU
Cable Category: Power Distribution
Input Voltage: 120/208V WYE
Output Voltage: 208V
Mounting: 0U Vertical Rack
Warranty: Five-year limited warranty
Standards: RoHS, UL & c-UL Listed 60950, FCC Part 15 Class A, TAA-Compliant
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources