Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: VA1U1100
UPC: 4061471343047
Condition: New
Write a Review 31% OFF

Vertiv Rpdu Rack Transfer Swch 10A 15A 120V 208 - VA1U1100

Vertiv VA1U1100 Rack PDU Transfer Switch 10-Outlet 15A 1UOverviewThe Vertiv VA1U1100 is a 1U rack-mount transfer switch designed to deliver basic powe…

$1,731.00 $1,186.99 SAVE $544
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Vertiv Rpdu Rack Transfer Swch 10A 15A 120V 208 - VA1U1100

$1,731.00
$1,186.99

Overview

SKU: VA1U1100
UPC: 4061471343047
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv VA1U1100 Rack PDU Transfer Switch 10-Outlet 15A 1U

Overview

The Vertiv VA1U1100 is a 1U rack-mount transfer switch designed to deliver basic power distribution with built-in source redundancy for server rooms, network closets, and edge deployments where uninterrupted power continuity matters. With a C14 input plug, ten C13 output receptacles, and a 3-meter cord, the VA1U1100 slots cleanly into standard 19-inch rack infrastructure and supports single-phase loads across a broad 100–240V input range — giving it flexibility across North American and international voltage environments.

This is a straightforward unit aimed at environments where you need reliable power switching without the complexity of managed or metered PDUs. If your rack holds network switches, NVRs, or edge servers that cannot tolerate even brief power interruptions during source failover, a transfer switch at this level handles that job without adding software overhead or management interfaces to your workflow.

Key Features

  • 10x C13 Output Receptacles: Ten IEC C13 outlets accommodate standard server PSUs, network switches, and IP camera recorders simultaneously — enough density for a fully populated 1U device without daisy-chaining additional strips.
  • C14 Input Coupler: The C14 input connector mates directly with standard rack PDU output or UPS C13/C14 whips — no adapters needed in most existing rack power architectures.
  • 100–240V / 50–60Hz Input Range: Wide input voltage tolerance means the VA1U1100 operates correctly whether your facility runs 120V branch circuits or 208V two-leg feeds, and it handles both 50Hz and 60Hz power grids — useful in mixed-voltage data hall environments or deployments that span multiple countries.
  • 15A Maximum Current / 230 VA Load Capacity: A 15A rating fits the most common branch circuit breaker sizes in North American commercial facilities, while the 230 VA continuous load ceiling keeps you out of nuisance-trip territory on lightly loaded racks. Size your connected load below that ceiling and the unit runs cool and stable.
  • 3-Meter Input Cord: The 3m (roughly 10 ft) cord reaches from a mid-rack PDU outlet or floor-level UPS to the device without requiring cable extensions — a practical detail that prevents strained connectors on short-cord installs.
  • 1U Horizontal Rack Mount: At 432mm wide × 457mm deep × 44mm tall, the VA1U1100 occupies exactly one rack unit in a standard 19-inch enclosure. Horizontal mounting keeps it accessible for outlet inspection and cord management without consuming vertical space inefficiently.
  • 0°C to 60°C Operating Range: The extended upper temperature limit — 60°C is well above most controlled data room specs — means the unit won't thermal-trip in dense or poorly cooled edge racks where ambient can climb during summer peak loads.
  • Black Enclosure / Single-Phase Architecture: Single-phase design matches the standard branch circuit topology in most commercial and light industrial facilities, avoiding the complexity of three-phase wiring for environments that don't need it.

Integration and Compatibility

The VA1U1100 is a passive hardware device — no firmware, no network interface, no SNMP agent. It integrates into any rack power architecture that uses standard IEC C13/C14 connectors. Pair it upstream with a compatible UPS or rack PDU supplying a C13 output, and downstream with any equipment using C13 power inlets. It is compatible with standard network switches, NVRs, and compute edge nodes that draw within the 15A/230VA envelope.

For deployments requiring power monitoring, outlet-level switching, or SNMP-based management, consider a metered or managed PDU from the broader Vertiv power distribution catalog — the VA1U1100 intentionally trades those features for simplicity and lower cost. Consult the rack PDU category for alternatives with remote switching or environmental monitoring built in.

Weight at 4.54 kg (approximately 10 lbs) is light enough for single-person rack installation using standard cage nuts and rack screws. No special tooling required.

Frequently Asked Questions

Q: What input connector does the VA1U1100 use, and what cord length is included?

A: The VA1U1100 uses a C14 coupler as its input connector and ships with a 3-meter (approximately 10-foot) input cord. This mates directly with C13 output receptacles found on most rack UPS units and upstream PDUs.

Q: How many outlets does the VA1U1100 provide, and what type are they?

A: The unit provides 10 IEC C13 output receptacles — the standard connector used by most 1U and 2U server power supplies, managed switches, and NVRs.

Q: What is the maximum current rating for the VA1U1100?

A: The VA1U1100 is rated for a maximum of 15 amps, with a continuous load capacity of 230 VA. This aligns with standard 15A branch circuits common in commercial facilities.

Q: Does the VA1U1100 work on both 120V and 208V circuits?

A: Yes. The unit supports a nominal input range of 100–240V at 50 or 60 Hz, making it compatible with both 120V single-phase and 208V two-leg circuits found in North American commercial and data center environments.

Q: Does the VA1U1100 include any network management or monitoring capabilities?

A: No. The VA1U1100 is a basic (unmanaged) transfer switch with no network interface, no SNMP agent, and no outlet-level switching. It is a passive power distribution device. If remote monitoring or managed switching is required, evaluate a metered or managed PDU from the Vertiv lineup instead.

Q: What rack space does the VA1U1100 require?

A: The VA1U1100 is a 1U horizontal rack-mount device measuring 432mm (W) × 457mm (D) × 44mm (H). It installs in a standard 19-inch rack enclosure.

Marty Allison
Marty Allison

The VA1U1100 is Vertiv's entry-level transfer switch targeting environments where you need basic source redundancy across 10 C13 loads without adding a managed PDU's cost or complexity. The 100–240V / 50–60Hz input tolerance is the spec I'd highlight first — it means a single SKU covers 120V US branch circuits and 208V two-leg feeds without procurement having to track two part numbers.

Technical Highlights:

  • 15A / 230 VA Capacity: Fits the most common commercial branch circuit breaker size; the 230 VA continuous ceiling keeps lightly loaded racks well below nuisance-trip thresholds on shared circuits.
  • 10x C13 Outputs + C14 Input: Direct C13/C14 compatibility means zero adapters in a standard rack UPS or PDU chain — the connector ecosystem matches what's already in virtually every 19-inch cabinet.
  • 0–60°C Operating Range: The 60°C upper limit provides headroom in dense edge racks and communication closets where ambient temperatures regularly exceed data center norms during peak load periods.

Deployment Considerations:

  • At 4.54 kg and 1U horizontal, this is a single-person rack install — but verify your rack has the full 457mm depth available; shallow-wall enclosures under 500mm deep may require cable management adjustments at the rear.
  • No management interface means no visibility into per-outlet load, no remote reboot, and no alerting — if any of those matter to your NOC, step up to a metered or managed Vertiv PDU before committing to this SKU.

The VA1U1100 is the right specification for a network closet or edge security rack running NVRs and PoE switches off a single UPS output, where the goal is clean power distribution to 10 loads and nothing more — not a managed data center PDU deployment.

Specifications
PDU types: Basic
Type: Single-phase
Rack capacity: 0U
Mounting: Horizontal
Product colour: Black
AC outlets quantity: 10 AC outlet(s)
Power plug: C14 coupler
AC outlet types: C13 coupler
Cable length: 3 m
Nominal input voltage: 100-240 V
AC input frequency: 50/60 Hz
Maximum current: 15 A
Load capacity: 230 VA
Operating temperature (T-T: 0 - 60 °C
Width: 432 mm
Depth: 457 mm
Height: 44 mm
Package weight: 4.54 kg
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources