Vertiv
SKU: CPQ-1081853-12
Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv FSC1U003 is a facility side cable designed to connect building power infrastructure to Vertiv rack PDUs in high-density data center and critical power environments. Rated for 60/63A service at 230V single-phase or 400V WYE three-phase, the FSC1U003 bridges the facility breaker panel to the rPDU inlet — the segment most often left to last-minute field improvisation. Having a factory-terminated, rated cable in place before the rack is commissioned removes a common source of installation delay and code ambiguity. The 3P+N+E connector carries a 5-wire configuration (three phase, neutral, earth), which is the standard requirement for balanced three-phase loads across European and international data center facilities. The IP44-rated plug provides splash and solid-object ingress protection sufficient for raised-floor environments and cable trays where incidental moisture contact is plausible. Operating frequency covers 50Hz and 60Hz infrastructure, and the cable is rated to 60°C ambient — above what most hot-aisle containment deployments actually sustain, so thermal derating is not a practical concern in standard rack deployments. Output is via a universal connector format matched to Vertiv rPDU inlets.
The FSC1U003 is engineered for use with Vertiv rPDU products requiring a 60/63A facility-side feed at 230/400V WYE. Compatible deployments include Vertiv Geist and Liebert rPDU families that accept a 3P+N+E inlet at this amperage class. Verify your specific rack PDU inlet configuration and ampacity rating before ordering — 32A and 16A Vertiv rPDU models use different facility cable variants and are not served by this SKU. Intended for 50/60Hz grid infrastructure; confirm local utility frequency and panel breaker rating at 63A before installation.
The 3P+N+E wiring requires a dedicated 60/63A three-phase circuit at the facility breaker panel. The IP44 plug rating assumes a mated, fully engaged connection — partial engagement or damaged housings degrade ingress protection. Confirm cable routing clearances and bend radius compliance with your data center's cable management standards before final dress. Operating temperature ceiling of 60°C applies to the cable assembly; ensure ambient along the cable run does not exceed this, particularly in sealed floor plenum or tightly bundled trays.