Vertiv GXT3-4-5K208L UPS - PBRGXT34X5K208L
5kVA power module designed for integration into Vertiv's PROREF PL GXT3-4-5K208L MULTI system
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv PBRGXT34X6K208V is a reference configuration identifier in the Vertiv power protection lineup, associated with the Liebert GXT3 series at a 6kVA capacity on a 208V input/output architecture. The GXT3 platform is a double-conversion online UPS designed for rack-mounted IT environments where continuous, regulated power is non-negotiable — think dense server rooms, network closets, and edge data center deployments where even a momentary sag or transient can cause unplanned downtime.
Double-conversion topology means incoming AC is continuously rectified to DC and inverted back to clean AC before reaching your load. Unlike line-interactive or standby designs, the output is always conditioned — input frequency and voltage variations are isolated from connected equipment without any transfer time. For rack UPS and power protection deployments supporting storage arrays, communications gear, or access control infrastructure, that isolation matters.
The PBRGXT34X6K208V references a GXT3-series configuration that fits standard 208V single-phase commercial branch circuits. Verify the specific outlet configuration and rack unit height against your cabinet layout before ordering — GXT3 6kVA units typically occupy 2U–5U depending on the exact build. For detailed input/output receptacle configurations, runtime curves, and network management card compatibility, consult the Vertiv Liebert product documentation or contact pre-sales engineering for a load audit before committing to this reference configuration.
Q: What does the PBRGXT34X6K208V reference configuration include?
A: The PBRGXT34X6K208V is a Vertiv reference configuration identifier for a GXT3-series 6kVA 208V rack UPS. Exact included components — battery modules, network management cards, outlet configurations — should be confirmed against the current Vertiv bill of materials for this reference number before purchase.
Q: What input voltage does the PBRGXT34X6K208V require?
A: This configuration is associated with a 208V input architecture, standard in commercial data center and server room branch circuits. It is not designed for standard 120V North American residential circuits.
Q: Can the GXT3 6kVA UPS be expanded with external battery cabinets?
A: The Vertiv GXT3 platform supports external battery cabinet expansion on compatible configurations. Verify compatibility with the specific PBRGXT34X6K208V build before ordering extended battery modules.
Q: Is the PBRGXT34X6K208V suitable for protecting security and surveillance infrastructure?
A: A 6kVA 208V rack UPS at this capacity is appropriately sized for mid-density security infrastructure — NVR stacks, PoE switch banks, and access control servers — where clean, conditioned power and runtime during outages are required for continuous recording and door access operations.

The PBRGXT34X6K208V sits in Vertiv's GXT3 reference configuration catalog at the 6kVA / 208V tier — a capacity point I see consistently in mid-density security infrastructure rooms where the load math works out to 4–5kW of actual draw across NVR servers, managed PoE switches, and access control head-end gear. Double-conversion online topology is the right call here: you're not gambling on a transfer time when a utility sag hits your recording infrastructure at 2 AM.
Technical Highlights:
Deployment Considerations:
Best fit: a dedicated security infrastructure rack in a commercial facility — 208V branch circuit available, mix of NVR servers and managed PoE switches, and a requirement for conditioned power with runtime that outlasts typical generator spin-up delays.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Vertiv products? Shop the full Vertiv catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price