Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit MDC82NS Pre-Configured Micro Data Center, NEMA 12 / 42U

Overview

The Panduit MDC82NS is a 42U, NEMA Type 12 pre-configured micro data center engineered for industrial automation environments where IT infrastructure must live outside a controlled computer room. Part of Panduit's IndustrialNet™ line, the MDC82NS ships as a complete, pre-integrated enclosure — 82.1 inches tall, 28 inches wide — ready to accept a 12,000 BTU cooling unit and go live on the plant floor or in a remote edge deployment. If you've struggled to deploy IT gear in a factory, water treatment facility, or harsh utility space while maintaining uptime and cable organization, this is the product class to evaluate.

Where a standard open rack leaves electronics exposed to industrial particulate, coolant mist, and vibration, the MDC82NS closes that gap with an IP55-rated, NEMA 12 enclosure tested to UL 508A — the industrial control panel standard. That's a meaningful difference when the nearest IT closet is a 30-minute walk from the production line.

Key Features

  • 42U Rack Space in a Closed NEMA 12 Enclosure: Forty-two rack units gives you room for a full edge compute stack — servers, switches, patch panels, UPS — without overflow. The closed NEMA 12 / IP55 rating means the cabinet actively excludes dripping water, dirt, oil, and industrial contaminants. Deploying this in a paint booth anteroom or near a CNC wash-down area is the right call; an open rack is not.
  • Pre-Configured from the Factory: The MDC82NS arrives with patch panels, cable management hardware, grounding, and casters already installed. That's hours of rack-build labor eliminated at the site — particularly valuable when electricians or integrators are billing against a tight commissioning window. You're not assembling a cabinet; you're positioning and connecting one.
  • Dedicated Cooling Aperture for 12,000 BTU Unit: One side panel is pre-cut and fitted for a 12,000 BTU cooling unit (not included). That BTU rating handles a dense edge compute shelf — plan your heat load and match accordingly. The aperture is designed to maintain the enclosure's sealed rating when the cooler is mated; field-cutting a generic cabinet does not provide that assurance.
  • UL 508A and EIA RS-310-D Compliance: UL 508A is the industrial control panel standard — relevant if your AHJ requires listed equipment on the plant floor or if your insurance underwriter mandates it. EIA RS-310-D governs rack dimensions and load ratings; equipment that specifies EIA compliance fits predictably. Both are listed under the MDC82NS's certified standards alongside NEMA 12 and IP55.
  • RoHS-Compliant Construction: RoHS compliance matters in manufacturing environments where equipment must meet environmental directives for EU exports or where corporate sustainability mandates apply. This isn't just a checkbox — it affects what happens to the unit at end of life and whether it clears procurement gates in regulated industries.
  • Integrated Cable Management and Grounding: Factory-installed cable management keeps patch runs organized at 42U density, and pre-installed grounding means the enclosure bonds correctly to your facility ground bus on day one. Grounding on industrial equipment is not optional — it directly affects both equipment protection and personnel safety in a noisy electrical environment.
  • Casters for Repositioning: Industrial deployments change. Casters let one or two people reposition the cabinet during line reconfigurations without a forklift. On a 28-inch-wide, 82-inch-tall enclosure that's going to hold several hundred pounds of equipment, that mobility is practical, not cosmetic.

Integration and Compatibility

The MDC82NS is designed around the IndustrialNet™ ecosystem, which covers Panduit's Panduit networking and infrastructure hardware including patch panels, cable managers, and industrial enclosures and racks. The 42U EIA-standard rack space accepts any EIA RS-310-D compliant equipment, meaning standard 19-inch server, switch, and patch panel form factors mount without adapters. The cooling aperture is specific to Panduit's compatible 12,000 BTU cooling unit — confirm the cooler model with your edge computing infrastructure order to ensure the sealed interface. Grounding hardware is pre-installed for integration with facility grounding and bonding systems per NEC and IEC standards. The enclosure's IP55 / NEMA 12 rating is maintained only when the cooling unit aperture is properly mated and all cable entry points are sealed — plan your conduit knockouts and gland plates before final installation.

Frequently Asked Questions

Q: What does NEMA 12 / IP55 protection mean for the MDC82NS in a factory setting?

A: NEMA 12 and IP55 both address protection against solid particulates and water ingress. IP55 specifically means the enclosure resists dust ingress (not fully dust-tight, but no harmful deposits) and protection against water jets from any direction. In a factory environment with coolant mist, metal filings, or wash-down operations nearby, this rating keeps electronics viable where an open rack or NEMA 1 enclosure would fail quickly. It does not mean the MDC82NS is rated for direct wash-down or full immersion.

Q: Is the 12,000 BTU cooling unit included with the MDC82NS?

A: No. The MDC82NS includes a side panel with a pre-cut aperture sized and sealed for a compatible 12,000 BTU cooling unit, but the cooler itself is a separate purchase. Confirm the compatible Panduit cooling unit model number before ordering to ensure the sealed-interface rating is maintained.

Q: What rack equipment fits in the MDC82NS?

A: Any standard 19-inch / EIA RS-310-D compliant equipment — servers, managed switches, patch panels, UPS units, fiber management — fits without adapters. The 42U height accommodates a full edge compute stack. Verify total equipment weight against the cabinet's load rating and caster capacity before populating.

Q: Does the MDC82NS meet UL 508A requirements for industrial installations?

A: Yes. UL 508A is listed among the standards met by the MDC82NS, which is relevant when an Authority Having Jurisdiction (AHJ) requires listed industrial control panel enclosures, or when insurance or corporate policy mandates UL-listed equipment on the plant floor.

Q: What is pre-installed in the MDC82NS from the factory?

A: The cabinet ships with patch panels, structured cabling, cable management hardware, grounding hardware, and casters pre-installed. The side panel opening for the 12,000 BTU cooling unit is also pre-configured. This eliminates the bulk of rack-build labor at the deployment site.

Q: What are the physical dimensions of the MDC82NS?

A: The MDC82NS stands 82.1 inches (2,085.5 mm) tall and is 28 inches (711.1 mm) wide. Confirm floor space and doorway clearance — particularly the width — before scheduling delivery to a confined industrial space.

Eden Phillips
Eden Phillips

The MDC82NS solves a specific problem I see repeatedly in industrial OT/IT convergence projects: the network closet doesn't exist on the plant floor, and the nearest IDF is 200 feet and three fire doors away. Panduit's pre-configured approach here isn't just convenient — the UL 508A listing and NEMA 12 / IP55 rating mean this cabinet can be placed where IT equipment normally cannot go, and it arrives with grounding, patch panels, and cable management already installed so your site crew isn't improvising rack builds in a live production area.

Technical Highlights:

  • NEMA 12 / IP55 Enclosure: IP55 blocks directed water jets and harmful dust accumulation — essential near CNC machines, paint lines, or packaging equipment where particulate and mist are constant. An open rack fails in months in these environments; this cabinet is rated to survive them.
  • 42U Pre-Configured Capacity: Forty-two rack units with pre-installed patch panels and cable management means you can install a complete edge node — compute, switching, fiber, and UPS — without a separate rack-build phase. On a plant commissioning schedule, that matters.
  • 12,000 BTU Cooling Aperture: The side panel is factory-cut and sealed for a specific cooler, not field-modified. That distinction preserves the IP55 rating. Field-cutting a standard cabinet and adding a generic unit usually voids both the enclosure rating and the cooling unit warranty — this is the correct way to do it.

Deployment Considerations:

  • The 28-inch width (711 mm) is narrower than a standard 24-inch-deep two-post cabinet but still requires careful doorway and aisle planning in retrofitted factory buildings — measure twice before scheduling the delivery truck.
  • The 12,000 BTU cooler is not included. Don't place the purchase order for the MDC82NS without confirming the compatible cooler part number and lead time — the aperture is pre-cut for Panduit's specific unit, and the sealed interface matters for IP55 compliance.

The MDC82NS is the right specification for edge IT nodes in automotive assembly, food and beverage processing, or utility substations where an IT closet build-out is not feasible and equipment must tolerate an industrial atmosphere. If your deployment is in a conditioned data center or a clean office IDF, a standard open rack is cheaper and faster — this cabinet's value is entirely in the protection and pre-integration it provides for harsh-environment edge deployments.

Specifications
Sub Brand: IndustrialNet™
Application: Industrielle Automatisierung
Height In: 82.1
Height Mm: 2085.5
Width In: 28
Width Mm: 711.1
Product Type: Mikrorechenzentrum
Carton Qty: 0
Package Qty: 1
Standards: EIA RS-310-D, UL 508A, NEMA 12 (UL-Typ), IP55, RoHS-konform
Upc: 61305657440
Cable Category: cabinets-thermal-management-racks-enclosures
freight: 717.98
Q&A
Reviews
Have Questions?

Panduit Pre-configurd Micro Data Center NEMA EA

$13,705.91
$11,135.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services