Rack Power Supplies
Showing Results for Rack Power Supplies
-
Vertiv
SKU: VP4N6032-R
Vertiv RPDU MONITORED 60A 36 ULOCK C19 - VP4N6032-R
In stock · Ships same business day$4,487.55 $3,143.99 Save $1,343.56 -
Vertiv
SKU: NI30671
Vertiv RPDU MONITORED 80A 277/480V 30 - NI30671
In stock · Ships same business day$5,731.63 $4,014.99 Save $1,716.64 -
Vertiv
SKU: VP4NA002-B
Vertiv RPDU MONITORED 80A 60 ULOCK C19 - VP4NA002-B
In stock · Ships same business day$4,455.57 $3,120.99 Save $1,334.58 -
Vertiv
SKU: VP6U60A1
Vertiv Rpdu Monitored Outlet Level 60/63A 240/415V WYE 43.4KW Vertical (48) Combi - VP6U60A1
In stock · Ships same business day$6,228.00 $4,270.99 Save $1,957.01 -
Vertiv
SKU: VP6U62A0
Vertiv Rpdu Monitored Outlet Level 60A/63A 200-240V 14.4KW Horizontal (24) Combin - VP6U62A0
In stock · Ships same business day$4,149.00 $2,845.99 Save $1,303.01 -
Vertiv
SKU: VP6U60A0
Vertiv Rpdu Monitored Outlet Level 60A/63A 200-240V 14.4KW Vertical (36) Combinat - VP6U60A0
In stock · Ships same business day$4,667.00 $3,200.99 Save $1,466.01 -
Vertiv
SKU: VP6UA0A0
Vertiv Rpdu Monitored Outlet Level 80A 240/415V WYE 57.6KW Vertical (36) Combinat - VP6UA0A0
In stock · Ships same business day$5,354.00 $3,671.99 Save $1,682.01 -
Vertiv
SKU: VP6UU0A0
Vertiv Rpdu Monitored Outlet Level EC 11.0KW Variable Power Configuration Vertical - VP6UU0A0
In stock · Ships same business day$4,073.00 $2,792.99 Save $1,280.01 -
Vertiv
SKU: VP6UU0A2
Vertiv Rpdu Monitored Outlet Level EC 11.0KW Variable Power Configuration Vertical - VP6UU0A2
In stock · Ships same business day$3,769.00 $2,584.99 Save $1,184.01 -
Vertiv
SKU: VP6N11A1
Vertiv Rpdu Monitored Outlet Level EC 15A 120V 1.4KW Horizontal (12) NEMA 5-15R - VP6N11A1
In stock · Ships same business day$1,894.00 $1,298.99 Save $595.01 -
Vertiv
SKU: VP6N11A0
Vertiv Rpdu Monitored Outlet Level EC 15A 120V 1.4KW Horizontal (6) NEMA 5-15R 1 - VP6N11A0
In stock · Ships same business day$1,541.00 $1,056.99 Save $484.01 -
Vertiv
SKU: VP6U20A0
Vertiv Rpdu Monitored Outlet Level EC 16A or 20A 120V or 208V or 230V 1.9KW or 3.3K - VP6U20A0
In stock · Ships same business day$2,511.00 $1,721.99 Save $789.01 -
Vertiv
SKU: VP6U20A1
Vertiv Rpdu Monitored Outlet Level EC 16A or 20A 120V or 208V or 230V 1.9KW or 3.3K - VP6U20A1
In stock · Ships same business day$2,492.00 $1,708.99 Save $783.01 -
Vertiv
SKU: VP6U20A2
Vertiv Rpdu Monitored Outlet Level EC 16A or 20A 120V or 208V or 230V 1.9KW or 3.3K - VP6U20A2
In stock · Ships same business day$2,492.00 $1,708.99 Save $783.01 -
Vertiv
SKU: VP6U20A3
Vertiv Rpdu Monitored Outlet Level EC 16A or 20A 120V or 208V or 230V 1.9KW or 3.3K - VP6U20A3
In stock · Ships same business day$1,859.00 $1,274.99 Save $584.01 -
Vertiv
SKU: VP6U21A0
Vertiv Rpdu Monitored Outlet Level EC 16A or 20A 120V or 208V or 230V 1.9KW or 3.3K - VP6U21A0
In stock · Ships same business day$1,859.00 $1,274.99 Save $584.01
Rack Power Supplies
Rack-mount power supplies deliver regulated DC to access control panels, CCTV head-ends, and intrusion systems from a 19-inch rack or cabinet. They provide battery backup, output supervision, and centralized distribution for multi-door or multi-camera installations.
Plan Your Deployment
- Output voltage (12/24 VDC) and total amperage at continuous load
- Rack units (1U, 2U, 3U) and depth for the cabinet
- Battery backup sizing (amp-hours) for target hold-up time
- Output count and individually fused/supervised channels
- Fire alarm interface for controlled lock release on alarm
What to Look For
Size the supply for 125% of the calculated continuous load and confirm the battery bank meets the hold-up time required by local code (commonly 4 or 24 hours). Supervised outputs report shorted or open circuits back to the panel, which is required for UL 1076 and UL 294 installations. Rack integration keeps service access at the central gear location.
Common Deployment Scenarios
Rack power supplies are standard in enterprise IDF closets, data center security rooms, and multi-door openings where copper home-runs converge on a central location. They replace scattered wall-wart or transformer-based power in larger systems.