Rack Power Supplies
Showing Results for Rack Power Supplies
-
Vertiv
SKU: VP6N21A2
Vertiv Rpdu Monitored Outlet Level EC 20A 240/415V WYE 11.5KW Horizontal (12) COM - VP6N21A2
In stock · Ships same business day$2,330.00 $1,597.99 Save $732.01 -
Vertiv
SKU: VP6N20AA
Vertiv Rpdu Monitored Outlet Level EC 20A 240/415V WYE 11.5KW Vertical (24) Combi - VP6N20AA
In stock · Ships same business day$2,753.00 $1,887.99 Save $865.01 -
Vertiv
SKU: VP6UV0A0
Vertiv Rpdu Monitored Outlet Level EC 22.0KW Variable Power Configuration Vertical - VP6UV0A0
In stock · Ships same business day$4,250.00 $2,914.99 Save $1,335.01 -
Vertiv
SKU: VP6UV0A2
Vertiv Rpdu Monitored Outlet Level EC 22.0KW Variable Power Configuration Vertical - VP6UV0A2
In stock · Ships same business day$5,070.00 $3,476.99 Save $1,593.01 -
Vertiv
SKU: VP6UV0A3
Vertiv Rpdu Monitored Outlet Level EC 22.0KW Variable Power Configuration Vertical - VP6UV0A3
In stock · Ships same business day$4,185.00 $2,869.99 Save $1,315.01 -
Vertiv
SKU: VP6N30AW
Vertiv Rpdu Monitored Outlet Level EC 30A 120/208V 5.7KW Vertical (24) Combinatio - VP6N30AW
In stock · Ships same business day$4,058.00 $2,782.99 Save $1,275.01 -
Vertiv
SKU: VP6N31A2
Vertiv Rpdu Monitored Outlet Level EC 30A 120/208V WYE 8.6KW Horizontal (12) Comb - VP6N31A2
In stock · Ships same business day$2,375.00 $1,628.99 Save $746.01 -
Vertiv
SKU: VP6N32A2
Vertiv Rpdu Monitored Outlet Level EC 30A 120/208V WYE 8.6KW Horizontal (24) Comb - VP6N32A2
In stock · Ships same business day$3,456.00 $2,369.99 Save $1,086.01 -
Vertiv
SKU: VP6N30A0
Vertiv Rpdu Monitored Outlet Level EC 30A 120/208V WYE 8.6KW Vertical (18) Lockin - VP6N30A0
In stock · Ships same business day$2,628.00 $1,802.99 Save $825.01 -
Vertiv
SKU: VP6N30A4
Vertiv Rpdu Monitored Outlet Level EC 30A 120/208V WYE 8.6KW Vertical (24) Lockin - VP6N30A4
In stock · Ships same business day$3,834.00 $2,629.99 Save $1,204.01 -
Vertiv
SKU: VP6N30AQ
Vertiv Rpdu Monitored Outlet Level EC 30A 120/208V WYE 8.6KW Vertical (36) Combin - VP6N30AQ
In stock · Ships same business day$3,866.00 $2,650.99 Save $1,215.01 -
Vertiv
SKU: VP6N31A0
Vertiv Rpdu Monitored Outlet Level EC 30A 120V 2.8KW Horizontal (12) NEMA 5-20R - VP6N31A0
In stock · Ships same business day$2,111.00 $1,447.99 Save $663.01 -
Vertiv
SKU: VP6N30A5
Vertiv Rpdu Monitored Outlet Level EC 30A 120V 2.8KW Vertical (24) NEMA 5-20R 10 - VP6N30A5
In stock · Ships same business day$2,540.00 $1,741.99 Save $798.01 -
Vertiv
SKU: VP6N31A1
Vertiv Rpdu Monitored Outlet Level EC 30A 208V 4.9KW Horizontal (12) Combination - VP6N31A1
In stock · Ships same business day$2,184.00 $1,497.99 Save $686.01 -
Vertiv
SKU: VP6N32A0
Vertiv Rpdu Monitored Outlet Level EC 30A 208V 4.9KW Horizontal (24) Combination - VP6N32A0
In stock · Ships same business day$3,236.00 $2,218.99 Save $1,017.01 -
Vertiv
SKU: VP6N30A7
Vertiv Rpdu Monitored Outlet Level EC 30A 208V 4.9KW Vertical (18) Locking IEC C1 - VP6N30A7
In stock · Ships same business day$2,561.00 $1,756.99 Save $804.01
Rack Power Supplies
Rack-mount power supplies deliver regulated DC to access control panels, CCTV head-ends, and intrusion systems from a 19-inch rack or cabinet. They provide battery backup, output supervision, and centralized distribution for multi-door or multi-camera installations.
Plan Your Deployment
- Output voltage (12/24 VDC) and total amperage at continuous load
- Rack units (1U, 2U, 3U) and depth for the cabinet
- Battery backup sizing (amp-hours) for target hold-up time
- Output count and individually fused/supervised channels
- Fire alarm interface for controlled lock release on alarm
What to Look For
Size the supply for 125% of the calculated continuous load and confirm the battery bank meets the hold-up time required by local code (commonly 4 or 24 hours). Supervised outputs report shorted or open circuits back to the panel, which is required for UL 1076 and UL 294 installations. Rack integration keeps service access at the central gear location.
Common Deployment Scenarios
Rack power supplies are standard in enterprise IDF closets, data center security rooms, and multi-door openings where copper home-runs converge on a central location. They replace scattered wall-wart or transformer-based power in larger systems.