Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
No Bots, Just Experts
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Panduit FZ2RLU1U1NNM1.5 OM4 LC Uniboot Duplex Fiber Patch Cable
The Panduit FZ2RLU1U1NNM1.5 is a 1.5-meter OM4 multimode fiber patch cable engineered for high-density data center and telecom room deployments where space is at a premium. This Opti-Core™ duplex jumper features LC Uniboot connectors on both ends, consolidating the traditional two-cable duplex assembly into a single 2mm round jacket that cuts rack congestion in half. The aqua LSZH (Low Smoke Zero Halogen) outer jacket meets stringent fire-safety codes for enclosed spaces, and the ultra-low insertion loss specification ensures reliable 40GBASE-SR4 and 100GBASE-SR4 transmission over OM4's 550-meter distance at 850nm. Installers working in crowded patch-panel environments gain faster moves-adds-changes thanks to the pull-boot design, which lets you extract the connector from dense SFP+ and QSFP+ arrays without disturbing adjacent links. At 4.92 feet, this cable length is ideal for top-of-rack switch uplinks, fiber cassette interconnects, and short cross-connects within the same cabinet or to an adjacent enclosure.
Key Features
- LC Uniboot Duplex Connectors — Single-boot housing reduces cable diameter by 50% compared to standard duplex zipcord; pull-tab extraction prevents strain on fiber during moves
- OM4 50/125µm Multimode Fiber — Supports 10G to 100m, 40G to 150m, and 100G to 150m over laser-optimized 850nm VCSEL transceivers; backward-compatible with OM3
- Ultra-Low Insertion Loss — Factory-terminated and tested to exceed TIA-568-C.3 performance; typical IL <0.15dB ensures margin for 40G/100G optics
- LSZH Jacket — Low smoke zero halogen outer sheath complies with IEC 60332-1 and IEC 61034 for plenum-equivalent installations; aqua color follows TIA-598-D OM4 standard
- 2.0mm Round Cable — Smaller bend radius and lighter weight than 3mm zipcord; easier routing through high-density cable managers and zero-U vertical trays
- Panduit Opti-Core™ Quality — End-face geometry polished to <50nm radius; every assembly serialized and traceable to manufacturing lot for warranty claims
Design & Deployment Context: The Uniboot form factor was developed to address a specific problem in modern leaf-spine fabrics: when you run 48 duplex links from a top-of-rack switch to a fiber patch panel, traditional zipcord consumes twice the horizontal space of copper, forcing installers to overfill cable managers or skip them entirely. Panduit's FZ2R series collapses the two 0.9mm tight-buffered fibers into a single round jacket with a single pull-boot housing, so your 48-port deployment looks and feels like 24 cables. The pull-boot itself incorporates a molded extraction tab that sits proud of the connector body; when you need to swap a link, you pinch the tab and pull straight back without finger-walking the connector or risking kinks in adjacent fibers. The 1.5-meter length hits the sweet spot for intra-rack and near-rack connections—long enough to route cleanly through vertical and horizontal managers with service loops, short enough that you're not coiling excess cable behind the switch. OM4 gives you 150 meters of 100G reach at 850nm, which covers every row-to-end-of-row scenario in a typical data center; if you're building out 40G or 100G server fabrics with MPO trunk cables and LC breakout cassettes, this jumper is the final-meter link between cassette and switch. The aqua jacket is the TIA-598-D mandated color for OM4, so your techs can distinguish it from OM3 (aqua with different laser optimization) or OM5 (lime green) at a glance during maintenance.
Materials & Standards Compliance: The fiber itself is laser-optimized 50/125µm multimode glass with an 850nm effective modal bandwidth of 4700MHz·km, exceeding the OM4 baseline of 4700MHz·km and positioning it for margin-sensitive 100GBASE-SR4 optics. Panduit factory-terminates every connector using precision ceramic ferrules with physical-contact (PC) polish; end-face geometry is inspected via interferometry to ensure <50nm apex offset and <150nm radius of curvature, both well within the TIA-604-3 (FOCIS-3) spec for LC. The LSZH jacket compound is halogen-free PVC alternative that generates <0.5% HCl when burned and produces light-transmission >60% during IEC 61034 smoke-density testing—critical for life-safety egress in occupied telecom rooms and under raised floors. The cable passes UL OFNP (plenum) flame spread per NFPA 262 and meets RoHS lead-free requirements for European installations. Panduit serializes each assembly with a printed label showing MPN, length, date code, and lot number; if you encounter an out-of-spec insertion loss or return loss during acceptance testing, you can trace it back to the manufacturing batch and get a replacement without arguing over whether it left the factory that way.
Installation & Performance Notes: LC Uniboot connectors are keyed, so polarity is fixed at the factory—typically Method-B (straight-through) unless you order a crossover variant. If you need to flip polarity in the field for a Method-A trunk, you'll need to open the boot and reverse the ferrule positions, which Panduit does not recommend doing repeatedly; plan your trunk polarity at design time. The 2.0mm cable has a minimum bend radius of 20mm during installation (10× diameter) and 10mm static (5×), tighter than 3mm zipcord; you can route it through finger ducts and around corners that would kink larger assemblies. Insertion loss is guaranteed <0.35dB average and <0.5dB maximum per TIA-568-C.3; Panduit's ultra-low-loss grade typically ships at <0.15dB, giving you 0.20dB of margin before you hit the 0.35dB tier-1 threshold. For 100GBASE-SR4 optics with a 1.9dB link budget (typical), that extra 0.2dB can be the difference between a clean link and one that flaps under temperature drift. Return loss is >20dB, preventing back-reflection from saturating VCSEL drivers. The cable is rated for -20°C to +70°C storage and 0°C to +70°C operation, suitable for climate-controlled data centers and most telecom Central Offices; if you're deploying in an outdoor cabinet or unheated MDF, verify your ambient range. Each duplex pair is factory-tested for continuity and polarity before it ships, so you won't discover swapped A/B fibers during Day-1 turn-up. The 1.5-meter length provides enough slack for a 6-inch service loop at each end plus vertical and horizontal routing; if your rack is deeper than 30 inches or you need to cross an aisle, step up to the 2m or 3m variant to avoid pulling the cable taut, which elevates insertion loss and risks ferrule endface damage over time.
Panduit FZ2RLU1U1NNM1.5 OM4 LC Duplex Patch 1.5m
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Panduit products? Shop the full Panduit catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology