Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv ITA2-60KRT400V37UPRN 60KVA 3-Phase Rack-Mount UPS

Overview

The Vertiv Liebert ITA2-60KRT400V37UPRN is a 60,000 VA rack-mountable uninterruptible power supply engineered for data centers and critical infrastructure environments that run 3-phase power at 400V. Operating on a 3-phase 5-wire input configuration at up to 75A, this unit is built to protect high-density compute, storage, and networking loads where a momentary outage means real operational consequences. At 37U, it occupies a significant portion of a standard rack — plan your cabinet layout accordingly — but delivers the power density that eliminates the need for multiple smaller units scattered across your floor.

Key Features

  • 60,000 VA Power Capacity: Handles the full electrical load of a densely populated server rack or a mid-scale data hall row — enough headroom to cover compute clusters, storage arrays, and network gear simultaneously without derating concerns under normal load profiles.
  • AC 400V / 3-Phase 5-Wire Input: Matches the standard European and international 3-phase distribution infrastructure directly, eliminating step-down transformers in facilities already wired for 400V — cleaner installation, fewer single points of failure in the power chain.
  • 75A Maximum Input Current: At 75A on a 3-phase 400V supply, this unit can sustain full rated load without tripping branch circuits — size your upstream breaker at 80A minimum (per NEC 125% continuous load rule or equivalent local code) to avoid nuisance trips during load transients.
  • Valve-Regulated Lead Acid (VRLA) Batteries: VRLA chemistry requires no electrolyte topping, vents minimally under normal operation, and can be installed in enclosed racks without special ventilation requirements — a practical advantage in sealed or positively pressured data rooms.
  • Rack-Mountable 37U Form Factor: Integrates directly into standard 19-inch rack infrastructure. The rack-mount form factor centralizes power protection at the cabinet level, simplifying cable management and keeping your UPS on the same monitoring plane as the equipment it protects.
  • Hardwire 3-Wire Input Connector: Hardwired input means no plug/socket rating limitations at this power level — appropriate for a 60KVA unit where standard connectors would be undersized and code-non-compliant in most jurisdictions.

Integration & Compatibility

The ITA2-60KRT400V37UPRN (often searched as ITA2 60KRT400V37UPRN) is designed for facilities running 400V 3-phase distribution — standard in European data centers and increasingly common in North American high-density deployments. The hardwire input requires qualified electrical installation; this is not a plug-and-play unit. Confirm your upstream panel supports 75A 3-phase breaker capacity before commissioning. The Vertiv Liebert platform broadly supports network management card options for SNMP/Modbus integration with DCIM and BMS systems — verify compatible NMC options with your facilities team prior to purchase, as management cards are typically ordered separately.

Frequently Asked Questions

Q: What input voltage and phase configuration does the ITA2-60KRT400V37UPRN require?

A: It requires AC 400V on a 3-phase 5-wire input with a maximum current draw of 75A. This matches standard European and international 3-phase distribution — not suitable for single-phase or 208V North American installations without a step-up transformer.

Q: What battery technology does the ITA2-60KRT400V37UPRN use?

A: It uses valve-regulated lead acid (VRLA) batteries. VRLA cells are sealed and maintenance-free under normal conditions, require no electrolyte servicing, and are safe for installation in enclosed rack environments without dedicated battery rooms.

Q: How much rack space does the ITA2-60KRT400V37UPRN consume?

A: The unit occupies 37U in a standard 19-inch rack. Plan for a dedicated full-height cabinet or confirm remaining rack space carefully before ordering — 37U leaves very little room in a standard 42U rack for other equipment.

Q: Does the ITA2-60KRT400V37UPRN require hardwired electrical installation?

A: Yes. The unit uses a hardwire 3-wire input connector. At 60KVA/75A, hardwired installation by a licensed electrician is required — no standard plug/socket combination is rated for this current level.

Q: What is the UPC for the ITA2-60KRT400V37UPRN?

A: The UPC is 767041044195.

Marty Allison
Marty Allison

The ITA2-60KRT400V37UPRN sits at the heavy end of rack-mounted UPS deployments — 60KVA on a 3-phase 400V feed with 75A maximum input is not a unit you drop into a standard server closet. This is purpose-built for data halls running European or international 3-phase distribution, where protecting a full cabinet row or a high-density compute pod from a single UPS point makes more operational sense than stacking multiple smaller units.

Technical Highlights:

  • 60,000 VA Capacity: Covers high-density rack rows — enough to sustain blade chassis, storage arrays, and top-of-rack switching simultaneously under real-world mixed loads.
  • VRLA Battery Chemistry: Sealed, maintenance-free cells mean no scheduled electrolyte checks and no special ventilation requirements — relevant when this unit lives inside a locked cabinet row in a shared colocation cage.
  • 75A / 3-Phase 5-Wire Input: Matches IEC 60364-compliant 400V distribution panels directly; no intermediate transformer needed in facilities already wired to this standard.

Deployment Considerations:

  • At 37U, this unit demands its own cabinet or a very carefully spec'd partial-height deployment — leaving only 5U in a standard 42U rack is not a realistic shared-use scenario.
  • Hardwired input at 75A is a licensed-electrician job in every jurisdiction — budget installation labor and upstream breaker work (size at 80A minimum for continuous load compliance) into your project timeline before the unit ships.

Best fit for European data center builds, colocation deployments on 400V 3-phase infrastructure, or international branch office server rooms where a single high-capacity UPS simplifies power chain management versus multiple distributed units.

Specifications
Form Factor: Rack-mountable
Input Voltage: AC 400 V
Power Capacity: 60000 VA
Input Configuration: 3-phase 5 Wire
Rack Height: 37U
Maximum Current: 75 A
freight: 954.90
Q&A
Reviews
Have Questions?

Vertiv ITA2 30KVA 400V Vrla 2+1 Parallel Bundle. - ITA2-60KRT400V37UPRN

$86,138.07
$59,066.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources