Middle Atlantic
SKU: ICAB-COOL
Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Middle Atlantic ICAB-COOL50 is a 50 CFM active cooling unit engineered for rack and cabinet thermal management in international deployments running on 220-240V AC mains. Unlike passive ventilation panels, this unit uses a powered fan assembly drawing 12VDC from an onboard supply to push air through the cabinet, removing heat before it accumulates around sensitive electronics. If you're sourcing for a project outside North America — or any installation where 120V is not the local standard — this is the correct unit to specify; buyers occasionally search for it as ICAB COOL50, but the MPN is ICAB-COOL50. For the full lineup of Middle Atlantic rack and AV solutions, including enclosures, power, and accessories, browse the brand page.
Thermal management is frequently the last item specced and the first thing that causes a callback. In enclosed rack environments — wall-mount enclosures, floor-standing cabinets, or integrated AV furniture — ambient temperatures inside the cabinet can climb 20-30°F above room temperature when equipment runs at load. The ICAB-COOL50 addresses this by actively moving 50 CFM of conditioned room air through the enclosure. At 2.75 in tall, it occupies roughly 2U of rack space, and its 10.63 in width and 10.17 in depth keep it compatible with common Middle Atlantic rack form factors without overhanging rear cable management. The black finish matches standard rack aesthetics. Explore the broader cabinet cooling and thermal management category for fan trays, blanking panels, and temperature controllers that can complement this unit.
For installations where the cooling unit will share a rack with UPS systems, PDUs, or high-density patch panels, review the power distribution category to ensure the mains circuit feeding the 220-240V input is correctly protected and load-balanced.
The ICAB-COOL50 is part of Middle Atlantic's Quiet-Cool cabinet cooling line, designed to integrate with Middle Atlantic rack enclosures. Verify the internal width and depth of the target cabinet against the unit's 10.63 in × 10.17 in footprint before specifying. The 220-240V input means this unit requires a standard IEC-type mains connection at the local voltage — confirm the cabinet's power strip or PDU provides a compatible outlet. Because the unit handles its own AC-to-DC conversion internally, no external 12V supply is needed; however, if the installation requires temperature-triggered fan control or remote monitoring, pair it with a compatible thermostat or environmental sensor rather than running the unit at continuous full speed. For rack enclosure options compatible with Middle Atlantic cooling accessories, see the rack enclosures category. If you are evaluating airflow requirements across a larger equipment room or multiple racks, the rack cooling planning guide covers airflow calculations and placement best practices.
Q: Is the ICAB-COOL50 compatible with 120V North American power?
A: No. The ICAB-COOL50 is rated for 220-240V AC input only. For North American 120V installations, Middle Atlantic offers separate Quiet-Cool models designed for that voltage range. Connecting this unit to 120V will result in insufficient fan operation or no operation at all.
Q: How much rack space does the ICAB-COOL50 occupy?
A: The unit is 2.75 inches (7 cm) tall, which typically occupies approximately 2U of rack space in standard 1.75-inch rail spacing. Confirm with your specific cabinet's rail configuration before ordering.
Q: Does the ICAB-COOL50 require an external DC power supply?
A: No. The unit includes an onboard AC-to-DC converter that accepts 220-240V AC and internally supplies the 12VDC needed by the fan motor. Connect it directly to a mains outlet inside the cabinet — no secondary power supply required.
Q: Can I deploy the ICAB-COOL50 on international projects in Europe or the Middle East?
A: Yes. The 220-240V input and international availability designation make this unit suitable for Europe, the Middle East, Australia, and most of Asia-Pacific. Verify local mains connector type and cabinet PDU compatibility before installation.
Q: Is this unit appropriate for outdoor or uncontrolled-environment enclosures?
A: The ICAB-COOL50 is designed for indoor rack and cabinet use in conditioned or semi-conditioned environments. It is not rated for outdoor installation or exposure to moisture or dust ingress beyond normal indoor conditions.
Q: What is the airflow direction — does it exhaust hot air out or pull cool air in?
A: Middle Atlantic's Quiet-Cool units are designed to move air through the cabinet. For specific airflow direction and recommended mounting orientation, consult the installation documentation at the manufacturer's product page on legrandav.com or contact Middle Atlantic technical support directly.

The ICAB-COOL50 solves a specific constraint cleanly: you have a Middle Atlantic cabinet on a 220-240V international site, the enclosure is running warm, and you need active airflow without retrofitting external cooling hardware or sourcing a step-down transformer. At 50 CFM in a 2.75-inch tall package, it fits the constraint set most international integrators are working within — and the onboard 12VDC conversion means you're not adding a second power draw to your rack's power budget.
Technical Highlights:
Deployment Considerations:
This unit is best suited for telecom closets, AV rack rooms, and access control head-end enclosures on international campuses — specifically where a Middle Atlantic cabinet is already specified and the local mains is 220-240V. It is not a substitute for room-level cooling in high-density server or data center environments.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Middle Atlantic products? Shop the full Middle Atlantic catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price