Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: RACSC101
Condition: New
Write a Review 35% OFF

APC by Schneider Electric Inrow SC System 1 Inrow SC 1 Netshelter SX Rack 600MM and Rear - RACSC101

APC by Schneider Electric RACSC101 InRow SC Cooling and Containment Rack SystemOverviewThe APC by Schneider Electric RACSC101 is a pre-engineered, int…

$22,125.00 $14,352.99 SAVE $7772
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC by Schneider Electric Inrow SC System 1 Inrow SC 1 Netshelter SX Rack 600MM and Rear - RACSC101

$22,125.00
$14,352.99

Overview

SKU: RACSC101
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric RACSC101 InRow SC Cooling and Containment Rack System

Overview

The APC by Schneider Electric RACSC101 is a pre-engineered, integrated data center row solution that combines an InRow SC cooling unit, a 42U NetShelter SX 600mm rack, and rear hot-aisle containment into a single procurable bundle. Where most rack deployments treat cooling, enclosure, and containment as three separate line items and three separate installation scopes, the RACSC101 consolidates the architecture up front — the cooling unit, the rack, and the rear containment panels arrive as a matched set, designed to work together at the row level rather than retrofitted after the fact.

This bundle targets small-to-mid-size data center rows, server closets, and edge compute deployments where precision cooling is required but floor space is constrained. The APC by Schneider Electric InRow approach puts the cooling unit physically adjacent to the heat load — inside the row, not across the room — which is the fundamental difference between row-based and room-based cooling strategies. If your raised-floor CRAC units are struggling to maintain consistent inlet temperatures across a dense row, this architecture directly addresses that problem.

Key Features

  • 42U NetShelter SX 600mm Rack: The 42U enclosure gives you standard rack-unit depth at 600mm wide — wide enough for full-depth servers and dual-post PDU runs, but narrower than 800mm frames, which matters when you're fitting multiple cabinets into a tight row footprint. Black finish is standard for enterprise environments.
  • 1200 CFM Airflow: The InRow SC unit moves 1,200 cubic feet per minute through the cooling coil. At typical data center densities of 5–10 kW per rack, 1,200 CFM is calibrated to handle the thermal load of one fully loaded 42U cabinet without over-provisioning the cooling capacity to the point of wasting energy on excess airflow.
  • 2940W Cooling Capacity: The system is rated to remove up to 2,940 watts of heat from the immediate row environment. Size your IT load accordingly — if you're projecting sustained loads above 2.9 kW on this rack, plan for supplemental cooling or evaluate the next tier of InRow capacity.
  • Rear Hot-Aisle Containment: The included rear containment panels close off the hot exhaust side of the rack, directing server exhaust directly into the InRow return path rather than letting it bleed back into the cold aisle or circulate through the room. Containment is the single highest-impact step you can take to improve cooling efficiency in a row-based deployment — it's far more effective than increasing airflow volume.
  • NEMA L6-20P Input Connection: The unit connects via a NEMA L6-20P twist-lock plug. This is a 240V, 20A locking connection — confirm your PDU or circuit panel has a matching L6-20R receptacle before deployment. L6-20P is not compatible with standard 120V NEMA 5-20 circuits.
  • 60 Hz AC Input Frequency: Designed for North American electrical infrastructure. Not suitable for 50 Hz environments without transformer intervention.
  • 900 x 1273 x 1991mm Footprint (W x D x H): At roughly 35
Specifications
Rack capacity: 42U
Type: Freestanding rack
Product colour: Black
Power supply: 2940 W
AC input frequency: 60 Hz
Storage temperature (T-T: 0 - 40 °C
Storage relative humidity (H-H: 0 - 95%
Weight: 331.7 kg
Dimensions (WxDxH: 900 x 1273 x 1991 mm
Airflow: 1200 CFM
Electrical input connection: NEMA L6-20P
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources