Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: ACAC75009
Condition: New
Write a Review 35% OFF

APC by Schneider Electric Inrow Receiver 17LB R410A 6 Diameter 18 Length - ACAC75009

APC by Schneider Electric ACAC75009 InRow Flooded Refrigerant ReceiverOverviewThe ACAC75009 is a factory-new, single-circuit flooded receiver designed…

$7,815.00 $5,057.99 SAVE $2757
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC by Schneider Electric Inrow Receiver 17LB R410A 6 Diameter 18 Length - ACAC75009

$7,815.00
$5,057.99

Overview

SKU: ACAC75009
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric ACAC75009 InRow Flooded Refrigerant Receiver

Overview

The ACAC75009 is a factory-new, single-circuit flooded receiver designed for APC InRow cooling systems using R410A refrigerant. At 17 lb capacity and a compact 6-inch diameter by 18-inch length, this metal receiver handles the liquid refrigerant storage function in precision air conditioning circuits where consistent pressure management directly affects cooling reliability in data center and telecom environments. If your InRow unit is flagged for a receiver replacement or you're expanding an existing precision cooling loop, the ACAC75009 is the exact-fit OEM component to restore correct refrigerant charge management — not a generic aftermarket substitute.

R410A systems require components sized and rated specifically for that refrigerant's higher operating pressures compared to legacy R22 or R404A circuits. Using an undersized or incompatible receiver in an R410A loop is a failure point that manifests as poor superheat control and compressor damage over time. The ACAC75009 is matched by APC by Schneider Electric for its InRow condenser architecture, eliminating that risk.

Key Features

  • 17 lb R410A Refrigerant Capacity: Sized to buffer liquid refrigerant volume in single-circuit InRow systems — enough headroom to handle load swings without starving the evaporator or flooding the compressor. Undersized receivers cause charge instability; this unit is spec'd to APC's InRow circuit requirements.
  • R410A Refrigerant Compatibility: R410A operates at roughly 60% higher pressures than R22. A receiver rated and validated for R410A eliminates the metallurgical and seal-compatibility risk that comes with using non-rated components in high-pressure cooling circuits.
  • 6-Inch Diameter, 18-Inch Length: The physical envelope (6" x 18") is set to fit APC's InRow condenser plumbing architecture. Before ordering, confirm clearance in your specific unit — InRow configurations vary by generation and footprint, and this receiver's 27" x 35.5" x 18" packaged dimensions determine your service access requirements.
  • Single-Circuit Design: Built for single-circuit refrigerant loops — the predominant topology in InRow precision cooling units. If your installation uses a dual-circuit or redundant refrigerant path, verify the circuit count before ordering; a single-circuit receiver on a dual-circuit system will not provide adequate charge management.
  • All-Metal Construction: Metal body withstands the pressure cycling and thermal stress inherent in precision cooling operation. Polymer or composite receivers have no place in high-pressure R410A commercial systems; metal construction here is the correct choice for the operating environment.
  • 17.06 lb (7.74 kg) Shipping Weight: Confirms a solid, full-metal assembly — relevant when planning service access in tight data center floor layouts. Factor the weight into rack-adjacent service procedures.
  • Packaged Quantity: 1 Unit: Ships as a single receiver. If your project requires parallel InRow units with individual receivers, order per unit to avoid short-shipping a multi-system refresh.

Integration & Compatibility

The ACAC75009 is a component-level part sourced from APC by Schneider Electric's InRow cooling line. It is intended for use within APC InRow precision air conditioning units — specifically those using R410A refrigerant in a single-circuit condenser configuration. This is not a standalone appliance; it is a HVAC cooling component that installs into an existing refrigerant circuit by a licensed HVAC technician. Compatibility is model- and generation-specific: cross-reference your InRow unit's service manual or APC's parts documentation to confirm ACAC75009 is the correct receiver for your specific unit before purchasing.

For broader precision cooling infrastructure planning, pairing this component service with a review of your data center cooling architecture and APC InRow cooling units ensures the replaced component returns the system to full manufacturer specification. Commissioning after installation should include refrigerant charge verification and leak-check per APC service procedures.

Frequently Asked Questions

Q: What refrigerant type does the ACAC75009 support?

A: The ACAC75009 is rated and designed specifically for R410A refrigerant. It is not rated for R22, R404A, or other refrigerant types. Confirm your InRow system uses R410A before installing this receiver.

Q: Is this a single-circuit or dual-circuit receiver?

A: The ACAC75009 is a single-circuit receiver. If your APC InRow unit uses a dual-circuit refrigerant configuration, this part is not appropriate — verify your unit's circuit topology in its service documentation first.

Q: What are the physical dimensions of the ACAC75009?

A: The receiver itself is 6 inches in diameter and 18 inches in length. Packaged dimensions are 27.008 x 35.5 x 18.0 inches (H x W x D) and the unit weighs 17.06 lb (7.74 kg).

Q: How much refrigerant does the ACAC75009 hold?

A: The ACAC75009 has a 17 lb refrigerant capacity, sized for the charge requirements of APC InRow single-circuit cooling systems.

Q: Does installation of the ACAC75009 require a licensed technician?

A: Yes. This is a refrigerant-circuit component. Handling R410A refrigerant and working on sealed HVAC systems requires EPA Section 608 certification and should be performed by a qualified HVAC technician. Do not attempt DIY installation.

Q: How do I confirm the ACAC75009 is the correct receiver for my APC InRow unit?

A: Cross-reference the part number against your specific InRow unit's service manual or APC's official parts documentation. InRow unit generations and configurations vary — model and serial number lookup is the reliable method to confirm fit before ordering.

Jerry Tildsen
Jerry Tildsen

The ACAC75009 is a component I'd call the unsung part of InRow refrigerant circuit maintenance — a 17 lb capacity single-circuit flooded receiver that, when it fails or degrades, causes charge instability that gets misdiagnosed as compressor or expansion valve issues for weeks. If you're troubleshooting an InRow unit with erratic superheat or recurring low-charge alarms and you've already ruled out leaks, this receiver is the next logical inspection point.

Technical Highlights:

  • 17 lb R410A Capacity: Adequate buffering for single-circuit InRow load cycling — enough volume to keep the liquid line stable during partial-load operation without oversizing the receiver to the point of refrigerant migration issues during system shutdown.
  • 6" Diameter x 18" Length Form Factor: This specific envelope is what APC engineered into the InRow condenser plumbing. Aftermarket receivers of similar capacity but different geometry create plumbing interference — dimensions matter as much as capacity rating here.
  • All-Metal Construction: R410A at operating pressures can exceed 400 psi on the high side in summer ambient conditions. Metal body is not optional — it's the minimum for a compliant, reliable installation in this application.

Deployment Considerations:

  • Have your InRow unit's model and serial number ready before ordering. APC's InRow line spans multiple generations with different condenser configurations — ACAC75009 is not universal across all InRow variants, and a mis-matched receiver means a return and a cooling outage extension.
  • R410A service requires EPA 608 certification. Factor licensed technician labor and refrigerant recovery/recharge costs into your project budget — this is not a field-swap component that an IT team handles independently.

The ACAC75009 is the right order for a data center facilities team managing an APC InRow precision cooling unit that's come due for refrigerant-side service — particularly in sites where cooling redundancy is limited and receiver failure cannot be absorbed by a standby unit.

Specifications
Product Type: Flooded Receiver
Cable Category: HVAC Condenser
Weight: 17.06 lb (7.74 kg)
Dimensions: 27.008 x 35.5 x 18.0 in (H x W x D)
Material: Metal
Diameter: 6 inches
Length: 18 inches
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources