Server Racks & Cabinets
Sub categories
Showing Results for Server Racks & Cabinets
-
APC by Schneider Electric
SKU: AR8725
APC by Schneider Electric Valueline Vertical Cable Manager for 2 & 4 Post Racks 84INCH - AR8725
In stock · Ships same business day$864.00 $567.99 Save $296.01 -
APC by Schneider Electric
SKU: AR8654
APC by Schneider Electric Cable Fall for Netshelter Racks and Enclosures (qty 2) - AR8654
In stock · Ships same business day$246.00 $245.99 Save $0.01 -
Middle Atlantic
SKU: AL3310B
Middle Atlantic Blank END Fitting - AL3310B
In stock · Ships same business day$20.69 $11.99 Save $8.70 -
APC by Schneider Electric
SKU: AR8561
APC Netshelter Cable Management Cable Trough Black 597 X 191.4 X 317.4 MM - T - AR8561
In stock · Ships same business day$288.00 $193.99 Save $94.01 -
APC by Schneider Electric
SKU: AR8469
APC by Schneider Electric Data Distribution Plastic Snap-in Panel Netshelter SX (qty 8) - AR8469
In stock · Ships same business day$80.00 $53.99 Save $26.01 -
APC by Schneider Electric
SKU: AR8450A
APC Netshelter Cable Management 4 Post Open Frame Trough and Partiton Adapter - AR8450A
In stock · Ships same business day$142.00 $141.99 Save $0.01 -
Vertiv
SKU: CM-77
Vertiv Cable Management Fingers 7 in X 7 RU - CM-77
In stock · Ships same business day$40.00 $39.99 Save $0.01 -
Vertiv
SKU: CM-47
Vertiv Cable Management Fingers 4 in X 7 RU - CM-47
In stock · Ships same business day$36.00 $35.99 Save $0.01 -
Vertiv
SKU: CM-28
Vertiv Cable Mngr 2RU 19 in W Hinge Cover - CM-28
In stock · Ships same business day$155.00 $154.99 Save $0.01 -
Vertiv
SKU: CM-27
Vertiv Cable Mngr 1RU 19 in W Hinge Cover - CM-27
In stock · Ships same business day$123.00 $122.99 Save $0.01 -
APC by Schneider Electric
SKU: AR8393BLK
APC AR8393BLK
In stock · Ships same business day$623.00 $423.99 Save $199.01 -
APC by Schneider Electric
SKU: AR8392BLK
APC by Schneider Electric Netshelter VX 42U Seismic Left Side Panel Black - AR8392BLK
In stock · Ships same business day$535.00 $365.99 Save $169.01 -
APC by Schneider Electric
SKU: AR8367BLK
APC by Schneider Electric Netshelter VX Side Panel 47U Black - AR8367BLK
In stock · Ships same business day$315.00 $221.99 Save $93.01 -
APC by Schneider Electric
SKU: AR8365BLK
APC by Schneider Electric Netshelter VX Front Door 47U 600MM Wide Black - AR8365BLK
In stock · Ships same business day$309.99 $292.99 Save $17.00 -
APC by Schneider Electric
SKU: AR8362BLK
APC by Schneider Electric Netshelter Vx-vs 42U Split Rear Doors 600MM Wide Black - AR8362BLK
In stock · Ships same business day$742.00 $496.99 Save $245.01 -
Vertiv
SKU: CM-17
Vertiv Cable Mngr 2RU 19 in W Cover - CM-17
In stock · Ships same business day$91.00 $90.99 Save $0.01
Server racks and cabinets are the structural foundation of any datacenter, MDF, IDF, or surveillance head-end. The right enclosure determines weight rating, airflow path, cable density, and how cleanly equipment is serviceable five years from now. Whether you're consolidating NVRs into a security closet, building an AV rack for a stadium control room, or standing up a 42U colocation cabinet, the chassis decision sets the ceiling for everything that mounts inside it.
Brands and product lines we stock
Middle Atlantic dominates the AV and security integrator space — MRK and BGR enclosed series for finished spaces, ERK open frames for service-side accessibility, and the SNE outdoor series for harsh environments. APC NetShelter SX and AR3100 cabinets are the datacenter workhorses with vendor-neutral cable management, perforated front and rear doors, and split-rear-door options for high-density deployments. Vertiv server racks cover seismic Zone 4, raised-floor, and hot-aisle/cold-aisle containment requirements.
What to consider when buying
- Static and dynamic weight load — fully loaded NVR + UPS + battery stack can exceed 2,500 lbs. Match the rated capacity, not the marketing number.
- U-height and usable depth — measure from front rail to rear rail, accounting for PDU and cable manager intrusion. Deep servers need 42 inch depth minimum.
- NEMA enclosure rating — NEMA 12 for dusty industrial, NEMA 4 for washdown, IP54 for outdoor mounting.
- Cable management integration — vertical PDU channels, side-panel D-rings, and rear cable basket compatibility.
- Airflow and ventilation — perforation percentage; front and rear doors should hit 65 percent open area minimum for hot-aisle deployments.
- Seismic certification — Zone 4 / GR-63-CORE / Telcordia compliance for west coast and telecom rooms.
- Lock and access control — keyed alike, combo, or electronic handle integration.
For high-density AI cluster builds and hot-aisle containment, see our cable management and Power & UPS selections. Working integrators on the Senior Specialist team can spec a full rack BOM including rails, PDUs, cable managers, and seismic anchoring — datacenter-grade builds with direct manufacturer sourcing.

