Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FRT12X4W6LYL FiberRunner 12x4 Horizontal Tee Fitting

The Panduit FRT12X4W6LYL is a 90-degree horizontal tee fitting for the Panduit FiberRunner 12x4 system, creating a branching junction in a horizontal fiber pathway — one straight-through channel splits to a perpendicular 6x4 outlet on the same horizontal plane. At 14.5 inches wide and 17.61 inches long, this fitting handles the geometry that inline duct sections simply can't, making it the structural anchor for any T-intersection in a data center or central office overhead fiber route. Constructed from polycarbonate/ABS and finished in the system's signature yellow, the FRT12X4W6LYL is purpose-matched to the FiberRunner 12x4 family and ships as a single unit.

Overview

Data centers and central telecom offices run fiber routing systems in three dimensions — straight runs are easy, but every junction introduces mechanical stress on cable bends if the fitting geometry isn't matched exactly to the duct size. This tee handles the 12x4 main run with a 6x4 branch, so fiber exiting the junction into a sub-route is properly supported in a correctly-sized channel rather than bent over a sharp edge or unsupported drop. The polycarbonate/ABS construction keeps the fitting light and dimensionally stable across the thermal cycles common in densely populated equipment rows.

Key Features

  • 90-Degree Horizontal Branch: The tee creates a perpendicular split on the horizontal plane — fiber leaving the main 12x4 run exits cleanly into a 6x4 branch without vertical elevation change. This is the correct fitting for same-level aisle-to-row transitions in raised-floor and overhead-tray data center layouts.
  • 12x4 Main / 6x4 Branch Geometry: The main channel matches the 12x4 FiberRunner trunk; the 6x4 branch outlet right-sizes the sub-route for lower-density drops. Properly matched duct dimensions protect bend radius on every cable that transitions from the main spine to a distribution branch.
  • Polycarbonate/ABS Construction: This material combination delivers impact resistance and dimensional stability without the brittleness of pure polycarbonate — useful in installations where overhead fittings may be contacted during cable adds or moves. The material also supports the fitting's UL listing without adding unnecessary weight to overhead infrastructure.
  • UL-Listed Fiber Optic Cable Routing Assemblies (through 2024): UL certification is a procurement requirement for many enterprise and carrier-class data centers. The FRT12X4W6LYL carries UL listing specifically for fiber optic cable routing assemblies, satisfying that gate without requiring separate documentation.
  • Telcordia GR-63-CORE and NEBS Level 3 Compliant: NEBS Level 3 is the environmental stress benchmark for telecom central office equipment — covering seismic, thermal, and airflow requirements. If your project scope includes carrier or co-location facilities with NEBS mandates, this fitting is already qualified; you don't need an engineering waiver for the passive routing infrastructure.
  • RoHS Compliant: RoHS compliance satisfies the restricted-substances gate on EU and many domestic enterprise procurement checklists. It's a checkbox requirement on most large-account RFPs — confirmed here.
  • Yellow Color Coding: The yellow finish matches the FiberRunner system's color convention for fiber pathways, making fiber routes visually distinct from copper or power infrastructure at a glance during moves, adds, and changes. In multi-tenant or high-density environments, color discipline reduces mis-routing incidents.
  • Overall Dimensions (14.5 in W × 17.61 in L × 4.22 in H): Knowing the footprint matters during pre-installation layout — this fitting occupies 14.5 inches of lateral span and 17.61 inches of run length at the junction, which must be accounted for in ladder rack or trapeze spacing plans before cable is pulled.

Integration & Compatibility

The FRT12X4W6LYL is designed exclusively for the FiberRunner 12x4 system. It does not cross-fit to 6x4 or 4x4 FiberRunner duct without an adapter, and it is not compatible with competing brands' fiber duct systems. Pair it with straight FiberRunner 12x4 sections, 12x4 vertical bends, and 12x4 end caps to complete the routing architecture. For the 6x4 branch run, transition to FiberRunner 6x4 sections immediately off this fitting's branch outlet. When planning network cable management overhead routes, account for the 14.5-inch width at each tee junction — this drives the minimum center-to-center spacing of adjacent parallel runs on a shared trapeze or ladder rack. For environments with strict change-management requirements, the fitting's UL listing and NEBS Level 3 qualification simplify approval for both new installs and retrofit projects in live carrier facilities.

What's in the Box

  • 1x Panduit FRT12X4W6LYL FiberRunner 12x4 Horizontal Tee Fitting (Yellow)

Frequently Asked Questions

Q: What duct sizes does the FRT12X4W6LYL connect?

A: The FRT12X4W6LYL connects to the FiberRunner 12x4 main run and branches to a 6x4 outlet. It is designed exclusively for use with the Panduit FiberRunner 12x4 system.

Q: Is the FRT12X4W6LYL NEBS Level 3 compliant?

A: Yes. The FRT12X4W6LYL meets Telcordia GR-63-CORE and Network Equipment Building Systems (NEBS) Level 3 standards, making it suitable for use in telecom central offices and carrier-class facilities with NEBS requirements.

Q: Is the FRT12X4W6LYL RoHS compliant?

A: Yes. The FRT12X4W6LYL is RoHS compliant, satisfying restricted-substances requirements for enterprise and EU procurement.

Q: What are the overall dimensions of the FRT12X4W6LYL?

A: The fitting measures 14.5 inches wide (368.3 mm), 17.61 inches long, and 4.22 inches tall (107.2 mm). Plan your ladder rack or trapeze spacing accordingly at each tee junction.

Q: What material is the FRT12X4W6LYL made from?

A: The fitting is constructed from polycarbonate/ABS, providing impact resistance and dimensional stability for data center overhead installations.

Q: How many units are included per order?

A: The FRT12X4W6LYL ships as a single unit (package quantity of 1).

Jerry Tildsen
Jerry Tildsen

The FRT12X4W6LYL is the fitting you reach for when a 12x4 FiberRunner spine needs to branch horizontally into a 6x4 sub-route — the 90-degree tee geometry on the horizontal plane is not interchangeable with a vertical or angled fitting, and using the wrong part forces cable bends that exceed minimum bend radius requirements on single-mode fiber. The 17.61-inch run length means you need to pre-plan junction spacing before laying out trapeze hangers; I've seen installations where the trapeze was set at 24-inch intervals that had to be re-spaced because the tee footprint demanded more clearance.

Technical Highlights:

  • NEBS Level 3 / Telcordia GR-63-CORE: For any project touching carrier infrastructure or co-location space, this qualification removes the passive routing hardware from the NEBS compliance review entirely — the fitting is pre-qualified, not just rated for a data center environment.
  • 14.5 in × 17.61 in footprint: Larger than most integrators expect for a single fitting. In tight overhead spaces with multiple parallel 12x4 runs, the lateral 14.5-inch width at each tee must be factored into your center-to-center run spacing or you'll be cutting custom trapeze offsets on-site.
  • Polycarbonate/ABS construction, UL-listed: The UL listing for fiber optic cable routing assemblies is current through 2024 per the standards documentation — verify the listing status against your project's authority-having-jurisdiction (AHJ) requirements if you're working on a permit-required install.

Deployment Considerations:

  • This fitting is sized for the 12x4 main channel only — the branch outlet is 6x4, so your sub-route must transition to FiberRunner 6x4 sections immediately. Don't try to continue 12x4 duct off the branch port; it won't mate.
  • The yellow color is a system convention, not a label substitute. In mixed-media overhead routes, supplement color coding with physical labeling at each tee to identify circuit direction during future MACs.

The FRT12X4W6LYL is the right spec for enterprise data center builds and carrier central offices where both structured cabling standards and NEBS qualification are non-negotiable — particularly in aisle-to-row fiber spine architectures where a clean horizontal branch keeps every cable's bend radius in spec without field fabrication.

Specifications
Sub Brand: FiberRunner™
Application: Data centers et bureaux de télécommunication centraux
Color: Jaune
Material: Polycarbonate/ABS
Height In: 4.22
Height Mm: 107.2
Width In: 14.5
Width Mm: 368.3
Product Type: Raccord en té
Carton Qty: 0
Package Qty: 1
Standards: Conforme RoHS, assemblages de guidage de câble optique certifiés UL jusqu'à 2024, conformes aux épreuves d'application des normes Telcordia GR-63-CORE et Network Equipment Building Systems niveau 3
Upc: 61305676402
Cable Category: wire-routing-management-protection
Type: Raccord en té
Q&A
Reviews
Have Questions?

Panduit Fitting Horz TEE W/ 6IN X 4IN EXPK1MOQ5

$344.54
$206.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources