Fire Alarm Panels

Sidebar
Selecting a sort option will reload the product list.

Showing Results for Fire Alarm Panels

  • Altronix ENTRADA2DMK IP Access FACP Adapters. Facilitates

    Altronix

    SKU: ENTRADA2DMK

    Altronix ENTRADA2DMK IP Access FACP Adapters. Facilitates

    IP adapter bridging fire alarm panels to access control networks

    • Two relay outputs for FACP signaling and cross-system event coordination
    • IP-based network protocol integration without replacing legacy panels
    • Compact module fits panel-mount or rack installation in retrofit setups
    $449.49 $240.99 Save $208.50
    The item has been added
    Free shipping over $499
    $449.49 $240.99 Save $208.50
    Add to quote
  • Potter AFC-1000E

    Potter

    SKU: AFC-1000E

    Potter AFC-1000E

    Multi-zone fire alarm panel with conventional and addressable detector support

    • Supports both conventional and addressable detector networks for retrofit or new builds.
    • Field-programmable zone configuration enables custom alarm verification and notification routing.
    • AC/DC power inputs with battery backup ensure continuous operation during outages; NFPA 72 compliant.
    $2,763.70 $1,770.99 Save $992.71
    The item has been added
    Free shipping over $499
    $2,763.70 $1,770.99 Save $992.71
    Add to quote
  • Potter CA-4064 Class A Expander for PFC-4064

    Potter

    SKU: CA-4064

    Potter CA-4064 Class A Expander for PFC-4064

    Class A expander for Potter PFC-4064 fire alarm panels

    • Class A supervised wiring ensures fault-tolerant operation if one circuit leg fails.
    • Expands addressable device and zone capacity on PFC-4064 panels without panel replacement.
    • Compact 4" × 6" × 1" form factor simplifies retrofit installs; backed by a 5-year warranty.
    $283.60 $180.99 Save $102.61
    The item has been added
    Free shipping over $499
    $283.60 $180.99 Save $102.61
    Add to quote
  • Potter IDC-6 Initiating Device Circuit Expander
    Add to Cart The item has been added

    Potter

    SKU: IDC-6

    Potter IDC-6 Initiating Device Circuit Expander

    IDC expander for Potter panels—add detector zones without replacing hardware

    • Slots into Potter panel expansion bays to add IDC zones without replacing hardware.
    • Mounts in panel, accessory cabinet, AE-2, AE-8, or AE-14 for flexible deployment.
    • Rated for 32°–120°F operation, supporting smoke, heat, and pull-station circuits.
    $580.90 $366.99 Save $213.91
    The item has been added
    Free shipping over $499
    $580.90 $366.99 Save $213.91
    Add to cart Add to quote
  • Potter PAD100-CD Carbon-Monoxide Detector
    Add to Cart The item has been added

    Potter

    SKU: PAD100-CD

    Potter PAD100-CD Carbon-Monoxide Detector

    Hardwired CO detector for Potter control panels with supervised zone input

    • Supervised zone input enables fault and tamper detection across multi-zone Potter panels.
    • Addressable low-voltage wiring simplifies integration into existing commercial alarm infrastructure.
    • Compact ceiling-mount form factor (36 mm, 92 g) fits HVAC returns and equipment rooms easily.
    $171.15 $110.99 Save $60.16
    The item has been added
    Free shipping over $499
    $171.15 $110.99 Save $60.16
    Add to cart Add to quote
  • Potter PAD100-LFSB Addressable Sounder Base

    Potter

    SKU: PAD100-LFSB

    Potter PAD100-LFSB Addressable Sounder Base

    Addressable low-frequency sounder base for Potter fire alarm systems

    • Addressable operation enables per-device control and status reporting on Potter alarm networks.
    • Low-frequency sounder output delivers audible notification suited for commercial and institutional spaces.
    • Compact 2.75 in profile supports ceiling or wall mounting to simplify installation placement.
    $229.50 $148.99 Save $80.51
    The item has been added
    Free shipping over $499
    $229.50 $148.99 Save $80.51
    Add to quote
  • Potter PAD100-SB Addressable Sounder Base

    Potter

    SKU: PAD100-SB

    Potter PAD100-SB Addressable Sounder Base

    Addressable sounder base for individual device control on fire alarm loops

    • Addressable loop architecture enables individual sounder control and device-level monitoring.
    • Integrates directly into addressable fire alarm loops, eliminating separate zone control relays.
    • Backed by a 5-year manufacturer warranty, reducing long-term maintenance risk on installed loops.
    $138.50 $89.99 Save $48.51
    The item has been added
    Free shipping over $499
    $138.50 $89.99 Save $48.51
    Add to quote
  • Potter PAD200-DUCT Analog Addressable Duct Detector (view 2)
    Add to Cart The item has been added

    Potter

    SKU: PAD200-DUCT

    Potter PAD200-DUCT Analog Addressable Duct Detector

    Analog addressable duct detector for HVAC smoke monitoring

    • Analog addressable loop reports exact detector address and live smoke levels to the panel.
    • UL 268 and UL 521 listed; UUKL listed for smoke control system integration.
    • Operates on 24 VDC across 32°F–120°F ambient range for standard commercial HVAC installs.
    $332.55 $208.99 Save $123.56
    The item has been added
    Free shipping over $499
    $332.55 $208.99 Save $123.56
    Add to cart Add to quote
  • Potter PAD200-DUCTR Analog Addressable Duct Detector
    Add to Cart The item has been added

    Potter

    SKU: PAD200-DUCTR

    Potter PAD200-DUCTR Analog Addressable Duct Detector

    Analog addressable duct detector for HVAC smoke monitoring

    • Analog addressable output streams continuous smoke-level data directly to the control panel.
    • Eliminates auxiliary relay modules by integrating natively with addressable fire alarm wiring.
    • UUKL Listed for Smoke Control; rated for ambient temps 32°F–120°F with a 5-year warranty.
    $496.00 $313.99 Save $182.01
    The item has been added
    Free shipping over $499
    $496.00 $313.99 Save $182.01
    Add to cart Add to quote
  • Potter PAD200-PCD Smoke & Carbon Monoxide Detector

    Potter

    SKU: PAD200-PCD

    Potter PAD200-PCD Smoke & Carbon Monoxide Detector

    Dual smoke & CO detector combines two life-safety sensors in one unit

    • Photoelectric smoke plus electrochemical CO sensing in one ceiling-mount unit.
    • Meets NFPA 72 smoke and UL 2075 CO detection requirements from a single device.
    • On-board test button verifies both sensors in the field without removing the unit.
    $270.85 $172.99 Save $97.86
    The item has been added
    Free shipping over $499
    $270.85 $172.99 Save $97.86
    Add to quote
  • Potter PAD200-PCHD combination smoke heat carbon monoxide detector with white casing

    Potter

    SKU: PAD200-PCHD

    Potter PAD200-PCHD Smoke / Heat / Carbon Monoxide Detector

    Triple-threat detector for smoke, heat, and carbon monoxide in one unit

    • Combines optical smoke, thermal heat, and electrochemical CO sensors in one unit.
    • Reduces ceiling penetrations and device count per monitoring point at installation.
    • UUKL Listed for Smoke Control; backed by a 5-year manufacturer warranty.
    $369.75 $237.99 Save $131.76
    The item has been added
    Free shipping over $499
    $369.75 $237.99 Save $131.76
    Add to quote
  • Potter PAD200-PD Photoelectric Smoke Sensor
    Add to Cart The item has been added

    Potter

    SKU: PAD200-PD

    Potter PAD200-PD Photoelectric Smoke Sensor

    Photoelectric smoke sensor for ceiling mount in commercial fire systems

    • Photoelectric technology targets visible smoke particles for early smoldering fire detection.
    • UUKL Listed for Smoke Control, supporting life safety compliance in commercial deployments.
    • Ceiling-mount form factor at 1.35" height integrates cleanly into standard fire alarm infrastructure.
    $126.50 $80.99 Save $45.51
    The item has been added
    Free shipping over $499
    $126.50 $80.99 Save $45.51
    Add to cart Add to quote
  • Potter PAD300-CD
    Add to Cart The item has been added

    Potter

    SKU: PAD300-CD

    Potter PAD300-CD

    Compact multi-reader access control panel for small to mid-size deployments

    • Multi-reader support enables flexible access point configuration across small to mid-size sites.
    • UUKL Listed for Smoke Control, confirming compliance for integrated life-safety deployments.
    • Compact ceiling-mount form factor simplifies retrofit installs with a 1.22-unit height profile.
    $148.45 $94.99 Save $53.46
    The item has been added
    Free shipping over $499
    $148.45 $94.99 Save $53.46
    Add to cart Add to quote
  • Potter PAD300-DD

    Potter

    SKU: PAD300-DD

    Potter PAD300-DD

    Multi-door access control panel with 12V/24V strike outputs

    • Controls electronic strike outputs at 12V or 24V for flexible door hardware compatibility.
    • Supports battery backup input for fail-secure operation during power loss events.
    • DIN rail or surface mount options simplify installation in varied enclosure types.
    $120.15 $77.99 Save $42.16
    The item has been added
    Free shipping over $499
    $120.15 $77.99 Save $42.16
    Add to quote
  • Potter PAD300-DUCT Duct-Mounted Smoke Detector
    Add to Cart The item has been added

    Potter

    SKU: PAD300-DUCT

    Potter PAD300-DUCT Duct-Mounted Smoke Detector

    Photoelectric duct smoke detector for supply/return air plenums

    • Photoelectric sensing catches smoldering fires in duct airstreams before smoke spreads.
    • Integrates with conventional supervised alarm loops for broad panel compatibility.
    • Compact 13.5" x 4.5" x 2.25" form factor fits standard commercial ductwork installations.
    $300.65 $188.99 Save $111.66
    The item has been added
    Free shipping over $499
    $300.65 $188.99 Save $111.66
    Add to cart Add to quote
  • Potter PAD300-DUCTR
    Add to Cart The item has been added

    Potter

    SKU: PAD300-DUCTR

    Potter PAD300-DUCTR

    Networked multi-door access control with encrypted credential support

    • Wiegand-compatible inputs support HID, Salto, Nedap, and other major reader platforms.
    • Ethernet-networked architecture enables remote credential provisioning and access management.
    • Encrypted credential transmission secures authentication data across all connected entry points.
    $454.70 $285.99 Save $168.71
    The item has been added
    Free shipping over $499
    $454.70 $285.99 Save $168.71
    Add to cart Add to quote

Fire Alarm Panels

Commercial fire alarm control panels for addressable and conventional fire detection systems. UL 864-listed FACPs support zone expansion, network annunciation, and central station communication for code-compliant life safety installations.

Plan Your Deployment

  • Determine addressable vs. conventional architecture based on building size and code requirements
  • Specify SLC loop capacity and total addressable point count for expansion headroom
  • Evaluate network communication for multi-panel campus or high-rise configurations
  • Confirm central station communication paths: DACT, IP, or cellular
  • Verify UL 864 listing and local AHJ requirements for panel certification

Fire Alarm Panels — Engineering-Grade Fire Detection for Commercial Deployments

This category covers 28 working models of fire alarm panels sourced manufacturer-direct or through channel-direct US distribution. Build the rest of your system around the architectural choices below — compatibility, environmental rating, and lifecycle decisions made here propagate through every downstream component you specify.

What to Look For

Addressable versus conventional architecture is the first decision. Conventional systems group detectors into zones; addressable systems identify the exact device that triggered. For buildings above 10,000 sq ft or with more than 20 detectors, addressable saves substantial diagnostic time and meets most modern code requirements. Conventional panels remain economical for small commercial buildings and retrofits where new wiring isn't feasible.

UL 864 listing is non-negotiable for the panel; UL 268 for smoke detectors, UL 521 for heat detectors. The AHJ will reject anything else. Beyond UL, look for FM Approval and CSFM (California) listings — many jurisdictions accept only those. Confirm panel-to-detector compatibility within the manufacturer's listed combinations; mixing brands across UL listings voids the panel's certification.

Notification appliance circuit (NAC) capacity, voltage drop, and battery backup sizing drive panel sizing more than detector count does. ADA-compliant strobes draw 75-175 mA each — a 50-strobe building exceeds many small NAC ratings. Calculate total NAC load with voltage-drop budget for the longest run, and size standby battery for 24 hours plus 5 minutes alarm per NFPA 72.

Central station communication, networked panel federation, and graphical workstations matter most in multi-building campuses. Single-building panels typically dial a central station via cellular and IP; multi-building campuses run proprietary peer-to-peer networks (Notifier NFN, Siemens FN-2127, Edwards SIGA) with master annunciation. Plan the integration topology before ordering panels — head-end choice affects which compatible peripherals you can deploy.

Key Specs in This Category

SpecAvailable Options
TypeController, Accessory, Fire alarm control panel, Fire alarm expander module, Initiating Device Circuit Expander, Carbon monoxide detector, Addressable Isolator Base, Addressable Sounder Base

Top Brands in This Category

Frequently Asked Questions

Do I need an addressable or conventional fire alarm panel?

Addressable panels identify the specific detector in alarm; conventional panels identify only the zone. NFPA 72 and most local codes require addressable for buildings above certain occupancy or square-footage thresholds, but the practical break-even is around 20-30 detectors. Above that count, addressable saves diagnostic and maintenance time. Below it, conventional is often the budget-friendly choice.

What's the difference between photoelectric and ionization smoke detectors?

Photoelectric detectors respond fastest to smoldering fires (cigarettes, electrical wiring); ionization detectors respond fastest to flaming fires (paper, kitchen). Modern dual-sensor detectors include both technologies and meet UL 268 7th edition requirements. Most jurisdictions now require dual-sensor or photoelectric for new commercial installations. Ionization-only is being phased out due to nuisance-alarm performance in cooking and shower-steam scenarios.

How often must fire alarm systems be inspected?

NFPA 72 requires annual inspection and testing of the entire system, semiannual battery testing, and monthly visual inspection of the panel. Local AHJ requirements often mandate documentation and a service contract with a licensed contractor. The owner-of-record bears legal responsibility for inspections — missing an annual inspection exposes the owner to fines and insurance claim denial.

Do I need a duct smoke detector?

Yes if the HVAC system exceeds 2,000 CFM (commercial threshold) — code requires duct smoke detectors that shut down the HVAC to prevent smoke distribution during a fire. Confirm CFM rating against local code thresholds; many jurisdictions require duct detection on smaller systems serving multiple-occupancy buildings. Duct detectors must report to the building's fire alarm panel.

What battery backup is required for fire panels?

NFPA 72 requires 24 hours of standby operation plus 5 minutes in full alarm. Calculate panel current draw under both conditions, then specify a battery with adequate Ah capacity. Lead-acid batteries lose capacity in cold environments — derate by 20% for unconditioned spaces. Replace batteries every 4-5 years even if they test good; failure rates climb steeply after year 5.

Need help choosing? Talk to a Senior Specialist — direct line 877-277-7147 or request a quote.