Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Hubbell FHPSCAS1SM SC/APC Single-Mode Fiber Optic Pigtail, 1 Meter
Overview
The Hubbell FHPSCAS1SM is a 1-meter SC/APC single-mode fiber optic pigtail designed for fusion-splicing into fiber distribution hubs, patch panels, and splice enclosures where a factory-polished, angle-polished connector end is required. Unlike a patch cord — which has connectors on both ends — this pigtail ships with one factory-terminated SC/APC connector and one stripped, bare fiber end ready for fusion splicing. The result is a splice point with the polish quality of a factory connector, not a field-terminated ferrule. That matters in single-mode runs where even modest back-reflection can degrade signal integrity across long distances.
The SC/APC (Angled Physical Contact) polish on the FHPSCAS1SM delivers a return loss typically greater than 60 dB — significantly better than the approximately 40 dB you get from a standard SC/UPC polish. In practice, that means less reflected light traveling back toward laser transmitters, which translates to cleaner signal at the receive end and fewer unexplained link errors in high-bandwidth single-mode systems. If your application uses DWDM, GPON, or any coherent transmission scheme, APC connectors are the correct choice; UPC is a compromise.
Key Features
- SC/APC Factory Polish: Angle-polished end-face delivers return loss typically exceeding 60 dB — the right spec for single-mode systems running GPON, CWDM, or any laser-sourced link where back-reflection causes transmitter instability.
- Single-Mode Fiber: Matched to OS1/OS2 single-mode infrastructure, so insertion loss stays consistent across the splice point rather than introducing mode-mismatch penalties you would get from a multimode pigtail used in a single-mode run.
- 1-Meter Pigtail Length: Sized for splice trays and distribution frames where you need enough slack to route through the enclosure and reach a fusion splicer chuck without stressing the fiber, but not so much excess that you are coiling surplus inside a tight tray.
- Bare-Fiber Splice End: Factory-stripped and cleaved-ready, so your fusion splicer produces a consistent splice geometry rather than dealing with field-stripped fiber of variable quality.
- SC Connector Form Factor: Push-pull latch mechanism is widely supported in patch panels, wall plates, and fiber distribution units — no specialty adapter required in most installed base environments.
- Hubbell Commercial-Grade Construction: Part of the Hubbell structured cabling line, built to the same dimensional tolerances as their fiber optic cables and assemblies — ferrule geometry is consistent lot-to-lot, which matters when you are splicing multiple pigtails in the same tray and need repeatable results.
Integration and Compatibility
The FHPSCAS1SM is compatible with any SC/APC-port device or panel: GPON OLT line cards, CWDM/DWDM mux/demux modules, single-mode fiber patch panels, and optical amplifier input/output ports. Pair it with a fusion splice-ready enclosure or splice tray that accommodates 900 µm tight-buffer pigtails. Confirm your splicer profile is set for single-mode before cleaving — a multimode splice profile will produce an incorrect arc duration and elevated splice loss. For a deeper look at choosing between pigtail and pre-terminated trunk methods, consult a fiber optic cabling selection guide before committing to one approach across a large installation.
Frequently Asked Questions
Q: What is the difference between SC/APC and SC/UPC, and which does the FHPSCAS1SM use?
A: The FHPSCAS1SM uses an SC/APC (Angled Physical Contact) polish. The angled end-face reduces back-reflection to typically greater than 60 dB return loss, compared to approximately 40 dB for SC/UPC. Use APC wherever the light source is a laser — GPON, CWDM, DWDM, or coherent systems. APC and UPC connectors are physically incompatible; do not mate them.
Q: Can I use the FHPSCAS1SM with multimode fiber infrastructure?
A: No. This is a single-mode pigtail. Connecting it into a multimode system introduces significant mode-mismatch loss and is not a supported configuration. Verify your fiber plant is OS1 or OS2 single-mode before ordering.
Q: Is 1 meter long enough for a standard splice tray?
A: For most 1U and 2U splice enclosures, 1 meter is adequate to route from the splice tray to the front connector panel with manageable slack. In deep wall-mount enclosures or when the splice tray is far from the port panel, confirm your routing path before ordering — a longer pigtail may be required.
Q: What fusion splicer settings should I use when terminating this pigtail?
A: Set your splicer to a single-mode profile (typically SMF-28 or equivalent G.652 fiber). Using a multimode arc profile on single-mode fiber produces inconsistent fusion geometry and elevated splice loss. Cleave the bare fiber end at 90° for best results.
Q: Does the FHPSCAS1SM come with a dust cap on the SC/APC connector?
A: Factory-terminated Hubbell fiber pigtails typically ship with a protective dust cap on the polished connector end. Verify with your order documentation; keep the cap installed until the moment of mating to protect the angled end-face from contamination.

When I specify pigtails for a single-mode distribution frame, the connector polish is the spec I look at first — and the FHPSCAS1SM gets that right with its SC/APC angle-polished end-face. In any laser-driven single-mode link, back-reflection is not a theoretical concern; it is a real source of transmitter noise that shows up as elevated BER on long spans or dense WDM channels. The APC geometry on this pigtail keeps that reflection well-suppressed.
Technical Highlights:
- SC/APC Polish: Angled physical contact end-face suppresses back-reflection to typically greater than 60 dB — roughly 20 dB better than SC/UPC, which matters on GPON OLT ports and coherent receive optics that are sensitive to reflected power.
- Single-Mode Fiber Match: Built for OS1/OS2 infrastructure; no cladding-diameter mismatch, no mode-field diameter penalty at the splice point — insertion loss stays predictable across the splice.
- 1-Meter Pigtail Body: Long enough to reach a front-panel port from a mid-tray splice point in a standard 1U or 2U enclosure, short enough that you are not forcing excess slack into a tight tray bend radius.
Deployment Considerations:
- Confirm your fusion splicer is profiled for single-mode (G.652 / SMF-28) before cleaving the bare end — an incorrect arc program produces splice loss that will not show up on a visual fault locator but will degrade OTDR traces and live signal margins.
- APC and UPC connectors cannot be mated — if your patch panel uses SC/UPC ports, the FHPSCAS1SM is the wrong pigtail. Audit your panel labeling (green = APC, blue = UPC) before ordering in quantity.
This pigtail is the correct choice for GPON last-mile splice enclosures, CWDM node distribution frames, and any single-mode backbone splice point where a field-terminated connector is not acceptable and a fusion splice to a factory-polished APC end is the specified method.
Hubbell FHPSCAS1SM SC-Single Mode Pigtail
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Hubbell products? Shop the full Hubbell catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology