Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv GL980ES-3042-B-MSS 52U Open Frame Server Cabinet with Split Mesh Rear Door

Overview

The Vertiv GL980ES-3042-B-MSS is a 52U, 30-inch-wide by 42-inch-deep enclosed server cabinet finished in black, configured with a split mesh rear door. It belongs to Vertiv's Geist line of data center infrastructure enclosures — a line built for environments where cable management, airflow discipline, and long-term scalability are non-negotiable. The GL980ES-3042-B-MSS (often searched as GL980ES 3042 B MSS) targets network equipment rooms, edge deployments, and server closets where rack density and airflow path matter as much as physical security.

At 52U, this cabinet gives you the vertical real estate to consolidate dense switching, compute, and patch infrastructure without stacking multiple shorter racks — a meaningful reduction in floor footprint for constrained machine rooms. The 30-inch width fits the standard EIA rack footprint, while the 42-inch depth accommodates deeper 1U/2U servers and high-density switch gear without forcing cable conflicts at the rear door.

Key Features

  • 52U Vertical Capacity: 52 rack units of usable space means you can populate a full spine-leaf switching stack, a row of 1U compute nodes, and patch infrastructure in a single enclosure — eliminating the cost and cabling complexity of a second cabinet in the same footprint.
  • 30-Inch Width: Standard 30-inch cabinet width fits within typical raised-floor tile spacing and aisle layouts without requiring custom floor cuts or repositioning adjacent racks. Compatible with the majority of standard 19-inch rack-mount equipment.
  • 42-Inch Depth: The 42-inch internal depth accommodates most enterprise-class servers and high-density switches — including chassis-based systems that routinely run 28–36 inches in body length — with room left for rear cable management and power distribution units.
  • Split Mesh Rear Door: A split rear door (two independently opening panels) allows rear access to specific equipment without swinging a full-height panel into a narrow hot aisle. Mesh construction supports passive airflow, reducing the risk of hot-spot buildup in non-raised-floor environments where convective cooling does meaningful work.
  • Mesh Contour Front Door Option: The mesh contour front door maintains positive airflow from front to rear while providing a physical barrier against accidental contact with live ports and cabling. This matters in shared or semi-public equipment rooms where non-technical staff may be present.
  • Black Finish: The black color variant blends into standard data center aesthetics and is the conventional choice for colocation environments and enterprise machine rooms. Vertiv also offers this family in Winter White for labs or manufacturing environments where visual contrast aids equipment identification.
  • Multi-Height Family: The GL980 series supports 24U, 42U, 44U, 48U, and 52U configurations, so if a future site requires a shorter rack or you're standardizing across locations, the same door hardware and accessory ecosystem applies — reducing spare parts inventory across your deployment fleet.
  • Width Variants Available: Beyond the 30-inch model, the GL980 family spans 24-inch and 32-inch widths. The 24-inch variant suits pure networking gear or dense patch environments; the 32-inch variant provides additional side clearance for wide-body UPS systems or dual-corded power strips running parallel.

Integration and Compatibility

The GL980ES-3042-B-MSS is designed around standard EIA 310-D 19-inch rack-mounting geometry, making it broadly compatible with equipment from Cisco, Aruba, Dell, HPE, Vertiv's own Liebert power distribution units, and essentially any vendor shipping standard 1U–4U rack-mount chassis. The 42-inch depth is sufficient for most current-generation 2-post and 4-post equipment without modification.

For power distribution, standard 0U vertical PDUs mount in the rear vertical channels, keeping the primary 30-inch width fully available for equipment mounting. Cable management accessories — horizontal lacing bars, vertical cable managers, and blanking panels — are sourced from the broader Vertiv data center infrastructure line to maintain consistent fit across the enclosure. If you're deploying multiple units in a server rack cabinet row, the GL980 series supports bolt-together side panels for row configurations, reducing rack-tip risk and improving lateral stability in seismic zones.

For environments where airflow management is a design constraint, consult a data center cooling reference to determine whether blanking panels are required to prevent recirculation through unpopulated U-space — a common oversight in partially-populated 52U deployments that causes thermal incidents at 60–70% fill. Pair with a power distribution unit rated for the anticipated load to complete the enclosure build-out.

Frequently Asked Questions

Q: What door configurations are available on the GL980ES-3042-B-MSS?

A: The GL980ES-3042-B-MSS ships with a mesh contour front door and a split mesh rear door. The split rear design allows access to either the upper or lower half of the rear independently, which is useful in tight hot-aisle configurations. Clear door variants are also available in the GL980 family if visual access to indicator LEDs without opening the door is a requirement.

Q: Will standard 1U servers and switches fit the 42-inch depth of this cabinet?

A: Yes. The 42-inch depth comfortably accommodates the majority of enterprise 1U and 2U servers, which typically measure 28–30 inches in body length. High-density chassis-based switches (Cisco Nexus, Aruba 8400, etc.) that approach 35–36 inches in depth also fit, though you should verify each specific unit's rear-connector-to-face-plate dimension and add cable bend radius before finalizing the layout.

Q: Can the GL980ES-3042-B-MSS be bolted to adjacent cabinets in a row configuration?

A: The GL980 series supports row configurations through side-panel bolt-together hardware. This improves lateral stability in multi-cabinet rows and is particularly relevant in environments with seismic considerations or heavy cable trays running above the row.

Q: Is the 30-inch width sufficient for mounting a vertical PDU alongside standard 19-inch rack equipment?

A: Standard 0U vertical PDUs mount in the rear vertical rail channels and do not consume any of the 30-inch horizontal mounting width. The 19-inch equipment mounting width remains unaffected. If you require side-mounted cable managers that project inward, verify clearance against the widest chassis in your stack.

Q: What other height options exist in the same GL980 family with the same 30x42 footprint?

A: Vertiv's GL980 line includes 24U, 42U, 44U, 48U, and 52U heights across the same width and depth options. If your equipment count doesn't justify a full 52U, the 42U or 48U variants in the same 30x42 footprint reduce cabinet height for low-ceiling environments while maintaining the same door and accessory compatibility.

Eden Phillips
Eden Phillips

The GL980ES-3042-B-MSS is built around a specific combination I see underspecified in a lot of edge and mid-tier data center projects: 52U height with a 42-inch depth and a split rear door. That rear door split is more consequential than it sounds — in a properly configured hot-aisle/cold-aisle row where rear clearance is under 36 inches, a full-height single rear door physically cannot open without hitting the cabinet behind it. The split design solves that without requiring you to redesign the aisle.

Technical Highlights:

  • 52U Capacity at 30x42: 52 rack units in a 30-inch-wide, 42-inch-deep footprint is a high-density configuration for a standard-width cabinet — you're getting maximum vertical real estate without widening your row or expanding your floor tile allocation.
  • Mesh Contour Front and Split Mesh Rear: Mesh on both door faces means front-to-rear airflow is not obstructed by the enclosure itself. In non-raised-floor environments relying on in-row or overhead cooling, an obstructed door face is one of the most common sources of unexpected hot-spot incidents.
  • Family Depth Flexibility (42in and 48in): The GL980 family supports both 42-inch and 48-inch depth variants. If you're running very deep chassis — dual-PSU storage arrays, for instance — the 48-inch depth variant of the same family picks up where this model stops, with the same door hardware and accessory set.

Deployment Considerations:

  • At 52U, partially-populated cabinets (below 70% fill) create recirculation risk through open U-space. Budget for blanking panels from the start — they're cheap insurance against thermal incidents that surface months after commissioning when load increases.
  • The 30-inch width is standard, but double-check your floor tile grid before ordering. Some older raised-floor environments with 24-inch tile spacing create awkward alignment for 30-inch cabinets depending on orientation — a detail that costs time on installation day if missed in planning.

This cabinet is the right specification for a mid-density server room or edge colocation build where rear aisle clearance is constrained, chassis depth exceeds 28 inches, and the team expects to add equipment incrementally over 18–36 months — the 52U headroom means you're not ordering a second cabinet after the first expansion cycle.

Specifications
Height: 24U42U44U48U52U
Width: 24"30"32"
Depth: 42"48"
Color: BlackWinter White
Doors: Mesh Contour Front/RearMesh Contour Front/Split Mesh RearClear
Q&A
Reviews
Have Questions?

Vertiv GL980ES-3042-B-MSS 52U Cabinet

$8,027.00
$5,429.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources