Altronix EFLOW104NB P/S & ACM8/VR6/PDS8 - MAXFIT7F8APS
Modular power distribution and surge protection unit designed to integrate with specific Altronix power supply and access control systems
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Altronix MAXFIT7F16APS is a fully integrated 16-door access power controller kit housed in a BC750 enclosure, combining an eFlow104NB power supply/charger, two ACMS8 dual-input access power controllers, a VR6 voltage regulator, and a PD16W power distribution module into a single ready-to-install assembly. It converts 120VAC/60Hz input into sixteen fuse-protected 24VDC distribution outputs and sixteen independently controlled 12VDC or 24VDC relay outputs — everything an integrator needs to power a full 16-door access control installation without sourcing and wiring separate components.
Designed for commercial and enterprise access control deployments, the MAXFIT7F16APS handles the full power distribution chain for door hardware — mag locks, electric strikes, magnetic door holders, and access control system accessories. Relays are activated by an open collector sink or normally open dry trigger input from an access control system, keypad, push button, REX PIR, or similar device. The FACP interface supports emergency egress, alarm monitoring, and auxiliary device triggering, with individually selectable fire alarm disconnect on any or all 16 relayed outputs — a critical feature for life-safety-compliant installations.
The MAXFIT7F16APS integrates with any access control system that provides open collector sink or normally open dry contact outputs for relay triggering — compatible with panel-based and IP-based ACS platforms without brand restriction. The FACP interface accepts standard fire alarm panel dry contacts. Battery backup uses standard sealed lead acid or gel type batteries (up to four 12AH/12VDC within the enclosure); larger 40AH or 65AH battery sets require a separate Altronix enclosure. The BC750 enclosure measures 16.5"W x 20.5"H x 6.25"D and weighs 28.1 lbs — size appropriately when planning closet or backbox installations. For broader access control power solutions or complementary hardware, the Altronix catalog includes enclosures, power supplies, and power distribution boards that extend this architecture. If you are sizing battery runtime, pair with an access control power supply reference or Altronix's NAC Power Extender Battery/Load Calculator. For installations requiring PoE-powered readers and IP controllers, consider adding a PoE switch for the IP side of the door stack.
Q: How many doors can the MAXFIT7F16APS support?
A: The kit supports up to 16 doors. It provides sixteen independently controlled relay outputs across two ACMS8 modules, plus sixteen fused 24VDC auxiliary outputs via the PD16W for readers and peripherals.
Q: What battery type and capacity does the eFlow104NB support?
A: The eFlow104NB charges sealed lead acid or gel type batteries. Up to four 12AH/12VDC batteries fit within the BC750 enclosure. Larger 40AH or 65AH battery sets require a separate external enclosure. Batteries are sold separately.
Q: Can outputs be individually configured for Fail-Safe or Fail-Secure operation?
A: Yes. Each of the eight outputs per ACMS8 (sixteen total) is individually selectable for Fail-Safe or Fail-Secure power output, Form C relay mode, or auxiliary unswitched power — configurable per door without affecting other outputs.
Q: Is the MAXFIT7F16APS listed for fire alarm applications?
A: Yes. It carries UL1481 listing for fire alarm power, UL294 for access control power, and UL603 for burglary alarm power. The cUL listing covers CAN/ULC-S319-05 and ULC-S318-96 for Canadian installations.
Q: What voltage outputs are available and are they field-selectable?
A: The ACMS8 relay outputs are individually selectable for either 12VDC (from the VR6 regulator) or 24VDC (from the eFlow104NB) on a per-output basis. The PD16W outputs are fixed at 24VDC. This lets you mix 12V and 24V door hardware on the same panel.
Q: What are the enclosure dimensions and weight?
A: The BC750 enclosure is 16.5"W x 20.5"H x 6.25"D and weighs 28.1 lbs (shipping weight 34.1 lbs). Plan wall anchoring accordingly for the populated weight.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Altronix products? Shop the full Altronix catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price