Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit QCRBCCB0002F066 66-Foot CAT6 UTP Copper Trunk Cable

Overview

The Panduit QCRBCCB0002F066 is a pre-terminated 66-foot Category 6 unshielded twisted pair (UTP) copper trunk cable engineered for high-density horizontal and backbone runs in data centers, telecommunications rooms, and enterprise structured cabling deployments. At 250 MHz bandwidth and rated for 1 Gbps data throughput, this trunk assembly is sized for the kind of bulk inter-rack or MDA-to-HDA runs where field termination introduces variability you don't want — and where a factory-terminated trunk delivers consistent, tested performance at pull time. Blue jacket color provides immediate visual lane identification in dense patch environments. Explore the full Panduit structured cabling line for complementary components.

Key Features

  • CAT6 / 250 MHz Bandwidth: Rated to 250 MHz, which comfortably headrooms Gigabit Ethernet and provides margin against alien crosstalk from adjacent cables in high-density trays. If you're running 10GBASE-T at shorter distances, verify channel budget separately — CAT6 supports 10G to 37–55 meters under the right conditions.
  • 1 Gbps Data Rate: Supports full-duplex 1000BASE-T across the 66-foot run length. For warehouse automation or IP surveillance backbones where PoE switches feed multiple downstream drops, this trunk handles the aggregated throughput without bottleneck at the horizontal tier.
  • UTP (Unshielded) Construction: No drain wire, no foil — which means faster field dressing, standard unshielded keystone tooling at patch panels, and no continuity issue if the shield ground path is broken. Correct choice for environments without significant EMI sources; if you're routing near industrial motor drives or high-voltage conduit runs, consider a shielded variant instead.
  • Pre-Terminated 66-Foot Factory Assembly: Factory termination eliminates the most common source of CAT6 performance failures — field-terminated connections that don't meet the standard's insertion loss and NEXT specs. The fixed 66-foot length is sized for inter-rack runs in mid-size data halls or from the telecom room to mid-floor consolidation points without a splice.
  • Blue Jacket Color Coding: In a multi-tier copper cabling environment, consistent color assignment by function (blue = data, for example) cuts mean-time-to-identify during moves, adds, and changes. This matters in 24/7 data center operations where a mis-trace under live load is a real risk.
  • TIA-568-C.2 and ISO/IEC 11801 Compliance: Dual-standard certification means this cable qualifies for both North American TIA-based designs and international EN 50173 / ISO projects — useful for multi-site enterprise rollouts where a single BOM needs to satisfy different regional specs.
  • UL Listed: UL Listing confirms the cable assembly has been independently tested to applicable safety standards, a requirement for installation in plenum or riser pathways in many jurisdictions. Verify your specific pathway rating requirements against the cable jacket rating before installation.

Integration & Compatibility

The QCRBCCB0002F066 is designed for integration with Panduit's QuickNet (QN) modular patching infrastructure — specifically the snap-in connector system used in QuickNet patch panels, cassettes, and trunk distribution units. Verify connector footprint compatibility with your existing patch panel hardware before ordering. The CAT6 UTP specification aligns with any standards-compliant CAT6 channel, so downstream drops terminating to TIA-568-C.2-compliant jacks will form a complete compliant channel.

For IP security and surveillance deployments, this trunk is an appropriate horizontal-tier cable for runs feeding PoE switches that power IP cameras, access control readers, and intercoms — keeping your PoE switch infrastructure within structured cabling compliance. Pair with compliant patch cords and keystone jacks to complete the channel. This cable does not carry shielding, so it is not appropriate as a direct replacement in shielded (F/UTP or S/FTP) channel designs.

Frequently Asked Questions

Q: What connector type does the QCRBCCB0002F066 use at each end?

A: This cable is part of Panduit's QuickNet (QN) trunk system, which uses Panduit's snap-in module connector format. It is not a standard RJ-45 patch cord — it is designed to mate with QuickNet-compatible patch panels and trunk distribution units. Confirm your panel hardware supports the QN connector footprint before ordering.

Q: Is this cable suitable for 10 Gigabit Ethernet runs?

A: CAT6 UTP supports 10GBASE-T at reduced distances — up to approximately 37–55 meters depending on alien crosstalk conditions. At 66 feet (approximately 20 meters), the run length is well within the 10G distance limit for CAT6, but full channel compliance (including patch cords and connectors) must be verified. For guaranteed 10G performance across longer distances, CAT6A is the standard choice.

Q: What standards does the QCRBCCB0002F066 comply with?

A: This cable meets TIA-568-C.2, ISO/IEC 11801, and is UL Listed. These are the primary North American and international structured cabling standards for Category 6 horizontal and backbone cabling.

Q: Can this trunk cable be used in plenum or riser-rated pathways?

A: The UL Listing indicates the cable has been independently safety-tested. However, plenum (CMP) or riser (CMR) pathway suitability depends on the specific jacket rating of this assembly. Verify the jacket fire-rating designation on the cable label or product documentation against your local code requirements before installation in air-handling spaces or vertical risers.

Q: Does the blue jacket color have a functional purpose or is it purely aesthetic?

A: The blue jacket is a color-coded lane identifier. In structured cabling deployments, consistent color assignment by network tier or function (e.g., blue for data, yellow for voice, green for patch) reduces mis-trace risk during MACs (moves, adds, changes) and speeds troubleshooting under live load. Panduit supports a full color palette across the QuickNet line for multi-lane environments.

Q: Is shielded cabling required, or is UTP sufficient for my application?

A: UTP is the correct choice for most enterprise office, data center, and commercial security installations where EMI from external sources is not a significant factor. If your cable routing passes near industrial motor drives, inverters, unshielded power conduit, or other high-EMI sources, a shielded (F/UTP or S/FTP) variant is the safer specification. This QCRBCCB0002F066 is UTP only.

Karl Wilson
Karl Wilson

The QCRBCCB0002F066 is a 66-foot pre-terminated CAT6 UTP trunk in Panduit's QuickNet system — and the spec that matters most here is the factory termination itself. Field-terminated CAT6 is where most cabling performance failures originate; a factory-terminated trunk assembly removes that variable entirely and delivers a tested, compliant channel segment at pull time. I specify this trunk for MDA-to-HDA runs and inter-rack horizontals where you need consistent 250 MHz headroom without relying on field tech skill level.

Technical Highlights:

  • 250 MHz CAT6 Rating: Provides meaningful headroom above the 100 MHz minimum for Gigabit Ethernet, and at the 66-foot (approximately 20-meter) run length, this cable is within CAT6's 10GBASE-T window — useful if your switch layer is 10G-capable even if the current NIC fleet is not.
  • UTP Construction: No shield means no grounding continuity requirement at the connector, faster dress-out in dense trays, and no shield-ground loop risk. In a clean data center environment without significant EMI, UTP delivers the same electrical performance as shielded at lower installation complexity.
  • Dual-Standard Compliance (TIA-568-C.2 / ISO/IEC 11801): Both standards on the same assembly simplifies multi-site BOM management for enterprise customers with North American and international footprints — you're not sourcing a different SKU for each regional spec.

Deployment Considerations:

  • This is a QuickNet snap-in trunk, not a field-terminable cable. It mates with Panduit QN patch panels and distribution units — confirm connector footprint compatibility with your existing panel hardware before cutting a PO, especially if you're retrofitting into a non-Panduit panel environment.
  • Blue jacket only; if your cabling standard calls for a different color lane assignment for this tier or function, the QuickNet line offers other jacket colors — verify SKU against your color-coding scheme at design time, not during installation.

This trunk is the right specification for a structured cabling refresh in a mid-size data center or enterprise telecom room where inter-rack horizontal runs are being migrated from field-terminated patch cords to pre-terminated trunk infrastructure — tighter performance consistency, faster deployment, and a compliant 1G/10G-capable channel in a single factory-tested assembly.

Specifications
Cable Category: copper_cable
Application: High-performance copper connectivity for data centers, telecommunications rooms, and enterprise networking environments.
Bandwidth: 250 MHz
Color: Blue
Data Rate: 1 Gbps
Shielding: UTP (Unshielded)
Standards: TIA-568-C.2, ISO/IEC 11801, UL Listed
Q&A
Reviews
Have Questions?

Panduit Copper QN Trnk CAT6UTP BU SCS 66FT PK 1 - QCRBCCB0002F066

$1,499.68
$971.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources